background image

 

Safety Notes

 

Gloves should be worn during installation to prevent crushing and cutting 
injuries.

 

The arm of the shower head is intended only to hold the shower head. Do not 
load it down with other objects!

 

Children as well as adults with physical, mental and/or sensoric impairments 
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.

 

Do not allow the streams of the shower touch sensitive body parts (such as your 
eyes). An adequate distance must be kept between the shower and you.

 

The product may not be used as a holding handle. A separate handle must be 
installed.

 

The shower system may only be used for bathing, hygienic and body cleaning 
purposes.

 

The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport damages. After it has been 

installed, no transport or surface damage will be honoured.

• The pipes and the fixture must be installed, flushed and tested as per the applica-

ble standards.

• The plumbing codes applicable in the respective countries must be oberserved.
• The installation dimensions stated in these installation instructions are ideal for 

people of approximately 1800 mm in body height. The dimensions can be 
altered if required. In this case, pay attention to the fact that a change of instal-
lation height will also change the minimum height, and that the altered mounting 
dimensions must be taken into consideration.

• Where the contractor mounts the product, he should ensure that the entire area of 

the wall to which the mounting plate is to be fitted, is flat (no projecting joints or 
tiles sticking out), that the structure of the wall is suitable for the installation of the 
product and has no weak points. The enclosed screws and dowels are only suit-
able for concrete. For another wall constructions the manufacturer's indications of 
the dowel manufacturer have to be taken into account.

• The mesh washer must be insert to protect the overhead shower against incoming 

dirt by pipework. Incoming dirt leads to defects or/and can damage parts of the 
shower; such caused faults voids all liability and guarantee claims.

• The product is not designed to be used with steam baths!
• If the water connections are not stabil mounted, the fitting must be fixed with extra 

screwsIf the water connections are not stabil mounted, the fitting must be fixed 
with extra screws (see page 32, fig. A1 - A11).  
With this type of installation, take care not to puncture the water pipe! If the 
water connections are stabil mounted, no extra screws are required (see page 
33, fig. B1 - B11).

Assembly see page 32

Fault

Cause

Remedy

Insufficient water

 

-

Supply pressure inadequate

 

-

Check water pressure (If a pump has been installed 
check to see if the pump is working).

 

-

Filters are dirty

 

-

Clean filter in front of the mixer and on the MTC-
thermo cartridge

 

-

Shower filter seal dirty

 

-

Clean filter seal between shower and hose

Crossflow, hot water being forced into cold water pipe, 
or vice versa, when mixer is closed

 

-

Backflow preventers dirty or leaking

 

-

Clean backflow preventers, exchange if necessary

Spout temperature does not correspond with tempera-
ture set

 

-

Thermostat has not been adjusted

 

-

Adjust thermostat

 

-

Hot water temperature too low

 

-

Increase hot water temperature to 42 ºC to 65 ºC

Temperature regulation not possible

 

-

thermo cartridge calcified

 

-

Exchange thermo cartridge

Instantaneous heater didn’t work

 

-

Filters are dirty

 

-

Clean the filter / exchange filter

 

-

check valve hasn't moved back

 

-

Exchange check valves

Cleaning 

(see page 40) and enclosed brochure

Operation 

(see page 42)

To empty the overhead shower after use, hold it in a slightly inclined 
position.

Flow diagram 

(see page 31)

  Hand shower

  overhead shower

Dimensions 

(see page 31)

Maintenance 

(see page 38)

• The mixer is equipped with check valves. The check valves must be 

checked regularly according to DIN EN 1717 in accordance with 
national or regional regulations (at least once a year).

• To guarantee the smooth running of the thermostat, it is necessary 

from time to time to turn the thermostat from total hot to total cold.

Adjustment 

(see page 36)

After the installation, the output temperature of the thermostat must be 
checked. A correction is necessary if the temperature measured at the 
output differs from the temperature set on the thermostat.

Safety Function 

(see page 37)

The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.

Do not use silicone containing acetic acid!

Symbol description

Technical Data

Operating pressure: 

max. 1MPa

Recommended operating pressure: 

0,2 - 0,5 MPa

Test pressure: 

1,6 MPa

(1 MPa = 10 bar = 147 PSI)
Hot water temperature: 

max. 80°C

Recommended hot water temp.: 

65°C

Thermal disinfection: 

max. 70°C / 4 min

Centre distance: 

150 ± 12 mm

Connections G 1/2: 

cold right - hot left

Safety against backflow

The product is exclusively designed for drinking water!

English

Spare parts 

(see page 39)

Special accessories 

(order as an extra)

tile-matching-disk chrome plated #92143000

Dismounting handle #98369000 

(see page 41)

4

Summary of Contents for Raindance Select 2jet 27283000

Page 1: ...Telefon 04621 30 60 89 0 Mail info unidomo com ffnungszeiten Mo Fr 8 00 17 00 Uhr a member of DAIKIN group Individuelle Beratung Komplettpakete Kostenloser Versand ber 15 Jahre Erfahrung Hochwertige...

Page 2: ...d k pou it Mont n n vod 11 SK N vod na pou itie Mont ny n vod 12 ZH 13 RU 14 HU Haszn lati tmutat Szerel si tmutat 15 FI K ytt ohje Asennusohje 16 SV Bruksanvisning Monteringsanvisning 17 LT Vartotojo...

Page 3: ...stalliert werden siehe Seite 32 Abb A1 A11 Bei dieser Installationsart ist darauf zu achten dass keine Wasserleitung ange bohrt wird Sind die Wasseranschl sse fest montiert werden keine zus tzlichen S...

Page 4: ...r ce type d installation veiller ne pas percer de conduite d eau Si les raccordements d eau sont d finitivement mont s des vis suppl mentaires sont superflues voir page 33 fig B1 B11 Montage voir page...

Page 5: ...a screws see page 32 fig A1 A11 With this type of installation take care not to puncture the water pipe If the water connections are stabil mounted no extra screws are required see page 33 fig B1 B11...

Page 6: ...mente installare allora l armatura con 2 4 viti supplementari vedi pagg 32 fig A1 A11 Per questo tipo di installazione fare attenzione che non venga perforata nessuna condotta d acqua Non sono richies...

Page 7: ...las conexiones de agua no estuviesen montadas de forma fija ser necesario instalar el grifo con tornillos adicionales ver p gina 32 fig A1 A11 Al realizar ese tipo de instalaci n es muy importante pro...

Page 8: ...ordenWanneer de wateraansluitingen niet vast gemonteerd zijn moet de armatuur aanvullend met schroeven vastgezet worden zie blz 32 afb A1 A11 Bij die wijze van installatie moet erop gelet worden dat g...

Page 9: ...denne montagemetode skal der holdes je med at der ikke bores ind i vandledninger Hvis avndtilslutningerne er fast monteret er yderligere skruer ikke n dvendige se s 33 fig B1 B11 Montering se s 32 Fe...

Page 10: ...rem fixamente montadas necess rio instalar a torneira adicionalmente com parafu sos ver p gina 32 fig A1 A11 Neste tipo de instala o necess rio ter em aten o que nenhuma tubagem de gua seja perfurada...

Page 11: ...od Je eli przy cza wody s w a ciwie zamontowane nie potrzeba adnych dodatkowych rub patrz strona 33 rys B1 B11 Monta patrz strona 32 Usterka Przyczyna Pomoc Ma a ilo wody Zbyt niskie ci nienie zasilaj...

Page 12: ...b t na to aby nedo lo k navrt n vodovodu Pokud jsou vodovodn p pojky nainstalov ny pevn nebude pot eba dal ch roub viz strana 33 obr B1 B11 Mont viz strana 32 Porucha P ina Odstran n M lo vody N zk tl...

Page 13: ...r A1 A11 Pri tomto druhu in tal cie je potrebn dba na to aby sa neprev talo vodovodn potrubie Ak s pr pojky vody namontovan pevne nevy aduj sa dodato n skrutky vi strana 33 obr B1 B11 Mont vi strana 3...

Page 14: ...1800 mm 32 A1 A11 33 B1 B11 32 MTC 42 C 65 C 40 42 31 31 38 DIN EN 1717 36 37 42 1MPa 0 2 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 80 C 65 C 70 C 4 150 12 mm G 1 2 39 92143000 98369000 41 13...

Page 15: ...00 Hansgrohe 32 A1 A11 33 B1 B11 32 42 65 40 42 31 31 38 DIN EN 1717 36 Safety Function 37 Safety Function 42 C 1 0 2 0 5 1 6 1 10 bar 147 PSI 80 C 65 C 70 C 4 150 12 mm G 1 2 39 92143000 98369000 41...

Page 16: ...ll arra hogy a v zvezet ket ne f rjuk meg Ha minden v zcsatlakoz s r gz tett akkor nincs sz ks g tov bbi csavarokra l sd a 33 oldalon bra B1 B11 Szerel s l sd a oldalon 32 Hiba Ok Megold s Kev s v z a...

Page 17: ...s ksi ruuvilla katso sivu 32 kuva A1 A11 T ss asennustavassa on varottava ett vesijohtoihin ei porata Jos vesiliit nn t on asennettu kiinte sti lis ruuveja ei tarvita katso sivu 33 kuva B1 B11 Asennus...

Page 18: ...tet r det viktigt att man inte borrar i n gon vattenled ning Om vattenanslutningarna r fast monterade beh vs inga extra skruvar se sidan 33 bild B1 B11 Montering se sidan 32 St rning Orsak tg rd F r l...

Page 19: ...tai n ra reikalingi r psl 33 pav B1 B11 Montavimas r psl 32 Gedimas Prie astis Priemon Per ma a srov Sl gis nepakankamas Patikrinti vamzd i spaudim U sikim s filtras I valyti termostato ir temperat ro...

Page 20: ...no instalirani dodatni vijci nisu potrebni pogledaj stranicu 33 sl B1 B11 Sastavljanje pogledaj stranicu 32 Gre ka Uzrok Otklanjanje Nedovoljno vode Prenizak pritisak vode Ispitajte tlak u cijevima Fi...

Page 21: ...c vata ile kurulmas gerekirSu ba lant lar sabit bir ekilde monte edilmediyse armat r n de c vata ile kurulmas gerekir bak n z sayfa 32 ekil A1 A11 Bu kurulum y nteminde su hatlar n n delinmemesine dik...

Page 22: ...ag 32 fig A1 A11 n cazul acestui tip de instalare trebuie s ave i grij s nu g uri i conductele de ap Dac racordurile de ap se monteaz fix nu mai este nevoie de uruburi suplimentare vezi pag 33 fig B1...

Page 23: ...E 32 A1 A11 E 33 B1 B11 32 42 C 65 C 40 42 31 31 38 DIN EN 1717 DIN 1988 36 Safety Function 37 Safety Function 42 C 1MPa 0 2 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 80 C 65 C 70 C 4 min 150 12 mm G 39 9...

Page 24: ...ovodnih cevi e so vodovodni priklju ki fiksno montirani ne potrebujete dodatnih vijakov glejte stran 33 sl B1 B11 Monta a glejte stran 32 Napaka Vzrok Pomo Malo vode Nezadosten oskrbovalni tlak Prever...

Page 25: ...mikudu on paigaldatud p sivalt ei ole t iendavaid kruvisid vaja vt lk 33 joonis B1 B11 Paigaldamine vt lk 32 Rike P hjus Lahendus V he vett Surve ebapiisav Kontrollige vee survet torudes kui pump on i...

Page 26: ...v m skat 32 lpp att A1 A11 Mont as gait j piev r uzman ba tam lai densvads netiktu urbts Ja dens piesl gumi ir cie i mont ti nav nepiecie amas nek das papildu skr ves skat 33 lpp att B1 B11 Mont a sk...

Page 27: ...instalirani dodatni zavrtnji nisu potrebni vidi stranu33 sl B1 B11 Monta a vidi stranu 32 Smetnja Uzrok Pomo Nedovoljno vode Prenizak pritisak vode Ispitajte pritisak u cevima Mre ice za hvatanje prlj...

Page 28: ...sse p at du ikke borer i noen av vannledningene Dersom vanntilkoblingen er fast montert er det ikke n dvendig med eksta skruer se side 33 bilde B1 B11 Montasje se side 32 Feil rsak Feilrettelse Lite v...

Page 29: ...sgrohe 32 A1 A11 33 B1 B11 32 42 C 65 C 40 42 31 31 38 DIN EN 1717 DIN 1988 36 Safety Function 37 Safety Function 42 C 1 0 2 0 5 1 6 1 10 bar 147 PSI 80 C 65 C 70 C 4 150 12 mm G 1 2 39 92143000 98369...

Page 30: ...n m nyr fikse at here nuk nevojiten bulona plot esues shih faqen33 fig B1 B11 Montimi shih faqen 32 Demtim Shkaku Ndihme Pak uj Presioni ushqyes jo Iimjaftueshem Kontrolloni presionin e tubacionit Sit...

Page 31: ...1800 32 A11 A1 B11 B1 33 32 42 65 40 42 31 31 38 DIN EN 1717 DIN 1988 36 37 42 1 0 5 0 2 1 6 PSI 147 10 1 80 C 65 C 4 70 C 150 12 mm G 39 92143000 41 98369000 30...

Page 32: ...pipe 27283000 27283400 Raindance Select 2jet Showerpipe 27283000 27283400 m i n 2 2 4 0 300 122 300 302 150 12 98 51 26 21 74 G 1 2 110 0 110 0 111 7 390 466 9 8 8 140 1 0 0 26 26 135 160 70 40 20 1 2...

Page 33: ...ntage 40 C 1 2 SW 5 mm 4 Nm 40 C SW 3 mm 3 Nm A3 A4 5 mm A5 A6 A8 A7 3 1 2 4 A9 2 1 1 2 A1 1 2 S i l i c o n e SW 5 mm 1 2 X X X 38 A2 1 2 5 mm X 38 mm 2x 4x A A10 A11 33 Nr 10476220 Armaturenfett G r...

Page 34: ...33 Montage 40 C B10 B9 40 C B3 B4 5 mm B5 B7 B6 2 1 40 C B8 1 2 B1 1 2 S i l i c o n e SW 5 mm SW 5 mm 4 Nm X X X 38 B2 1 2 5 mm X 38 mm B 40 C B11 34 SW 3 mm 3 Nm...

Page 35: ...34 Montage 12 2 Nr 10476220 Armaturenfett G rease 1 40 C 40 C 13 14 40 C 15 40 C 16 40 C 18 40 C 17 40 C 19 1 2...

Page 36: ...35 Montage 40 C 26 40 C Silicone 25 40 C 40 C 1 20 2 3 4 1 2 2 1 21a 21b 2 1 2 SW 4 mm SW 17 mm 10 Nm 22 23 24...

Page 37: ...Justierung 1 2 3 4 5 36...

Page 38: ...37 Safety Function 1 z B 42 C for example 42 C 2 3 2 1 5 6 7 8 4...

Page 39: ...38 40 C Silicone 1 2 40 C Wartung 40 C 40 C 40 C 3 5 1 6 4 1 2 2 3 7 1 2 3 2 8 40 C 9 SW 22 mm SW 5 mm SW 22 mm 4 Nm SW 5 mm 4 Nm SW 3 mm SW 3 mm 3 Nm 1 1 2 3 1 2 1 2...

Page 40: ...8000 28276000 95758000 98368000 M28x1 5 SW 19 mm 98140000 20x1 98367000 98282000 98913000 M34x1 5 SW 27 mm 98370000 98369000 28331000 98918000 96659000 9 l min 26521000 26521400 98058000 98117000 9x1...

Page 41: ...40 Reinigung 2 4 5 8 SW 5 mm 2 Nm 50 mm 3 10 6 7 SW 5 mm SW 17 mm SW 17 mm 10 Nm 1b 9b 1 min...

Page 42: ...Demontage 41 3 5 6 1 min 1 2 4 40 C 40 C 3x 3 4 5 6 40 C 40 C 3x 1 2...

Page 43: ...zavrie bez r s sulkeminen st nga u daryti Zatvaranje kapatmak nchi de zapreti sulgege aizv rt zatvori lukke mbylle warm chaud hot caldo caliente warm varmt quente ciep a tepl tepl meleg l mmin varmt k...

Page 44: ...43...

Page 45: ...Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 08 2014 9 02654 01 44 Pr fzeichen...

Reviews: