Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The shower system may only be used for bathing, hygienic and body cleaning
purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be oberserved.
• The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact that a change of instal-
lation height will also change the minimum height, and that the altered mounting
dimensions must be taken into consideration.
• Where the contractor mounts the product, he should ensure that the entire area of
the wall to which the mounting plate is to be fitted, is flat (no projecting joints or
tiles sticking out), that the structure of the wall is suitable for the installation of the
product and has no weak points. The enclosed screws and dowels are only suit-
able for concrete. For another wall constructions the manufacturer's indications of
the dowel manufacturer have to be taken into account.
• The mesh washer must be insert to protect the overhead shower against incoming
dirt by pipework. Incoming dirt leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and guarantee claims.
• The product is not designed to be used with steam baths!
• If the water connections are not stabil mounted, the fitting must be fixed with extra
screwsIf the water connections are not stabil mounted, the fitting must be fixed
with extra screws (see page 32, fig. A1 - A11).
With this type of installation, take care not to puncture the water pipe! If the
water connections are stabil mounted, no extra screws are required (see page
33, fig. B1 - B11).
Assembly see page 32
Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump has been installed
check to see if the pump is working).
-
Filters are dirty
-
Clean filter in front of the mixer and on the MTC-
thermo cartridge
-
Shower filter seal dirty
-
Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
-
Backflow preventers dirty or leaking
-
Clean backflow preventers, exchange if necessary
Spout temperature does not correspond with tempera-
ture set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to 42 ºC to 65 ºC
Temperature regulation not possible
-
thermo cartridge calcified
-
Exchange thermo cartridge
Instantaneous heater didn’t work
-
Filters are dirty
-
Clean the filter / exchange filter
-
check valve hasn't moved back
-
Exchange check valves
Cleaning
(see page 40) and enclosed brochure
Operation
(see page 42)
To empty the overhead shower after use, hold it in a slightly inclined
position.
Flow diagram
(see page 31)
Hand shower
overhead shower
Dimensions
(see page 31)
Maintenance
(see page 38)
• The mixer is equipped with check valves. The check valves must be
checked regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
Adjustment
(see page 36)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Safety Function
(see page 37)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Do not use silicone containing acetic acid!
Symbol description
Technical Data
Operating pressure:
max. 1MPa
Recommended operating pressure:
0,2 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
Centre distance:
150 ± 12 mm
Connections G 1/2:
cold right - hot left
Safety against backflow
The product is exclusively designed for drinking water!
English
Spare parts
(see page 39)
Special accessories
(order as an extra)
tile-matching-disk chrome plated #92143000
Dismounting handle #98369000
(see page 41)
4
Summary of Contents for Raindance Select 2jet 27283000
Page 37: ...Justierung 1 2 3 4 5 36...
Page 38: ...37 Safety Function 1 z B 42 C for example 42 C 2 3 2 1 5 6 7 8 4...
Page 41: ...40 Reinigung 2 4 5 8 SW 5 mm 2 Nm 50 mm 3 10 6 7 SW 5 mm SW 17 mm SW 17 mm 10 Nm 1b 9b 1 min...
Page 42: ...Demontage 41 3 5 6 1 min 1 2 4 40 C 40 C 3x 3 4 5 6 40 C 40 C 3x 1 2...
Page 44: ...43...