6
6 6
Safety Notes
6
Gloves should be worn during installation to prevent crushing and cutting
injuries.
6
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
6
Children as well as adults with physical, mental and/or sensoric impairments
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
6
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
6
The product may not be used as a holding handle. A separate handle must be
installed.
6
The shower system may only be used for bathing, hygienic and body cleansing
purposes.
6
The hot and cold supplies must be of equal pressures.
Installation Instructions
• The fitting must be installed, flushed and tested after the valid norms.
• Where the contractor mounts the product, he should ensure that the entire area of
the wall to which the mounting plate is to be fitted, is flat (no projecting joints or
tiles sticking out), that the structure of the wall is suitable for the installation of the
product and has no weak points. The enclosed screws and dowels are only suit-
able for concrete. For another wall constructions the manufacturer’s indications of
the dowel manufacturer have to be taken into account.
• The filter insert (97708000) must be used to ensure the standard flow rate and
to protect the hand shower against incoming dirt by pipework. Do you want a
larger water flow rate, then you must use the filter packing (94246000) instead
of the filter insert (97708000). Incoming dirt leads to defects or/and can dam-
age parts of the hand shower; such caused faults voids all liability and guarantee
claims.
• In case of emergencies, the lower part of the pipe can be shortened by means of
a fine saw.
• With the excentric washer it is possible to equalize tolerance of the drilling
(see page 32, Fig. 18).
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,25 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Connections:
cold right - hot left
anti-pollution function
English
Symbol description
Safety Function
(see page 33)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Adjustment
(see page 33)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Do not use silicone containing acetic acid!
Spare parts
(see page 39)
Operation
(see page 35)
Maintenance
(see page 36)
The non return valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least once
a year).
To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
Cleaning
(see page 37)
enclosed brochure
Assembly see page 31
Flow diagram
(see page 34)
overhead shower
hand shower
overhead hand shower
Test certificate
(see page 35)
Dimensions
(see page 34)
Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Regulator filter dirty
- Clean filters
- Shower filter seal dirty
- Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water
pipe, or vice versa, when mixer is closed
- Backflow preventers dirty or leaking
- Clean backflow preventers, exchange if necessary
Spout temperature does not correspond with tem-
perature set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to 42 ºC to 65 ºC
Temperature regulation not possible
- Temperature regulator dirty or calcified
- Clean temperature regulator, exchange if necessary
- For new installations: basic body incorrectly con-
nected (should be: cold right, hot left) or installed
with 180º rotation
- Install function block turned through 180º
Safety stop button not operating
- Spring defective
- Button calcified
- Clean spring and/or button, exchange if necessary
Diverter stiff
- Cartridge defective
- Clean spring and/or button, exchange if necessary
Diverter leaking
- Dirt or sedimentation on valve seat, shut-off unit dam-
aged
- Clean valve seat or exchange diverter
4
Summary of Contents for Raindance 27145000
Page 31: ...31 1 1 2 2 Silicone SW 5 mm 3 SW 5 mm 4 SW 6 mm 5 6 1 2 7 8 9 1 2 10 11 12 X 3mm ...
Page 32: ...32 13 1 2 SW 3 mm 14 SW 2 mm 15 Ø 6 mm 16a Silicone 16b Silicone 17 19 1 2 3 B A 22 21 18 20 ...
Page 33: ...1 2 3 4 5 1 2 3 33 ...
Page 37: ...37 1 3 2 5 4 6 1 2 2 1 1 2 ...
Page 38: ...38 1 4 3 2 1 min 1 2 4 3 SW 5 mm AIR SW 4 mm ECO SW 5 mm AIR SW 4 mm ECO 2 Nm 1 2 2 1 ...