3
Assembly
(see page 4)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• The fitting must be installed, flushed and tested after
the valid norms!
• The plumbing codes applicable in the respective
countries must be oberserved.
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
Technical Data
Operating pressure:
max. 1,6 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Centre distance:
150 ±15 mm
Connections G 1/2:
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking water!
English
Spare parts
(see page 13)
Dimensions
(see page 6)
Do not use silicone containing acetic acid!
Operation
(see page 5)
Flow diagram
(see page 7)
Cleaning
(see page 8)
Maintenance
(see page 11)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Fault
Cause
Remedy
Insufficient water
- Shower filter seal dirty
- Clean filter seal between shower
and hose
- check valve hasn't moved back
- Exchange check valves
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Instantaneous heater didn’t work
- Flow limiter in handshower isn’t
removed
- Remove flow limiter
- Filters are dirty
- Clean the filter / exchange filter
- check valve hasn't moved back
- Exchange check valves
Symbol description
Summary of Contents for PuraVida 15672007
Page 4: ...4 Montage 1 2 1 3 2 4 SW 5mm 6 Nm 150 16 5 6 7 2 min SW 27mm 1 2 3...
Page 5: ...5 Bedienung Bedienung 1 2 open close hot cold open close...
Page 6: ...6 G 1 2 G1 2 PuraVida 15472007 15472407 PuraVida 15672007 15672407 G 1 2 G1 2...
Page 8: ...8 QuickClean QuickClean Hansgrohe Hansgrohe www hansgrohe int com guarantee QUICK CLEAN...
Page 10: ...10 Reinigung 1 2 3...
Page 11: ...11 Wartung Wartung 1 3 1 2 2 1 2...
Page 14: ...14...
Page 15: ...15...