Safety Notes

 

Gloves should be worn during installation to prevent 

crushing and cutting injuries.

 

The product may only be used for bathing, hygienic 

and body cleaning purposes.

 

The hot and cold supplies must be of equal 

pressures.

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 

surface damage will be honoured.

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be observed.

Technical Data

Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 70°C 

Recommended hot water temp.: 

65°C 

Thermal disinfection: 

max. 70°C / 4 min

• Safety against backflow
• The product is exclusively designed for drinking 

water!

Symbol description

Do not use silicone containing acetic acid!

Adjustment 

(see page 6)

To adjust the hot water limiter. Using a hot water limiter 

in combination with a continuous flow water heater is 

not recommended.

Maintenance 

(see page 9)

• The check valves must be checked regularly 

according to DIN EN 1717 in accordance with 

national or regional regulations (at least once a 

year).

Dimensions 

(see page 8)

Flow diagram 

(see page 8)

Spare parts 

(see page 10)

Cleaning 

(see page 11)

Operation 

(see page 7)

Assembly 

(see page 4)

Fault

Cause

Remedy

Insufficient water

- check valve hasn't moved back

- Exchange check valves

- Shower filter seal dirty

- Clean filter seal between shower 

and hose

Mixer stiff

- Cartridge defective, calcified

- Exchange cartridge

Mixer dripping

- Cartridge defective

- Exchange cartridge

Hot water temperature too low

- Hot water limiter incorrectly set

- Set hot water limiter

Instantaneous heater didn’t work

- Flow limiter in handshower isn’t re-

moved

- Remove flow limiter

- Shower filter seal dirty

- Clean filter seal between shower 

and hose

- check valve hasn't moved back

- Exchange check valves

Summary of Contents for Metris S 31460019

Page 1: ...EN Instructions for use assembly instructions 2 DE Gebrauchsanleitung Montageanleitung 3 Metris S 31460019 Metris S 31660019 ...

Page 2: ... Symbol description Do not use silicone containing acetic acid Adjustment see page 6 To adjust the hot water limiter Using a hot water limiter in combination with a continuous flow water heater is not recommended Maintenance see page 9 The check valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations at least once a year Dimensions see page 8 F...

Page 3: ...Silikon verwenden Justierung siehe Seite 6 Einstellen der Warmwasserbegrenzung In Verbindung mit Durchlauferhitzern ist eine Warmwassersperre nicht zu empfehlen Wartung siehe Seite 9 Rückflussverhinderer müssen gemäß DIN EN 1717 regelmäßig in Übereinstimmung mit nationalen oder regionalen Bestimmungen auf ihre Funktion geprüft werden mindestens einmal jährlich Maße siehe Seite 8 Durchflussdiagramm...

Page 4: ...4 X 36 mm X 36 X 1 3b 2 3a 1 2 1 2 Silicone 36 mm max 39 mm max 5 mm 4 SW 24 mm 5 ...

Page 5: ...5 6 7 8 SW 30 mm 17 Nm 9 11 10 SW 22 mm 2 min SW 22 mm 2 Nm ...

Page 6: ...0 3 MPa 60 C 10 C 2 1 3 4 5 6 7 4 3 1 2 3 1 2 6 x 36 C 38 C 43 C 50 C 55 C 60 C 17 x S W 4 m m S W 4 m m 5 N m SW 4 mm SW 4 mm 6 ...

Page 7: ...7 open öffnen close schließen hot warm cold kalt close shower schließen Brause 1 2 open shower öffnen Brause ...

Page 8: ...45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec Ø 20 12 15 175 G 1 2 77 Ø 68 189 107 29 77 G 1 2 Ø 46 150 54 G 1 2...

Page 9: ...9 2 1 2 1 3 1 2 ...

Page 10: ...97220000 94140000 98163000 15x2 95646001 96512000 98137000 17x1 5 97209000 96466000 97738000 Metris S 31460019 Metris S 31660019 96467000 96157000 97220000 98163000 15x2 98129000 14x2 95008000 95140000 98193000 32x2 97406000 96338000 31093000 96044019 92839000 92839000 95646001 97209000 94140000 ...

Page 11: ...ng recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation EN Cleaning recommendation Warranty Contact DE Reinigungsempfehlung Garantie Kontakt ...

Page 12: ...12 Hansgrohe Auestraße 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 05 2019 9 05370 64 ...

Reviews: