4
English
Assembly
(see page 35)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 42)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Maintenance
(see page 45)
The check valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions
(see page 43)
Flow diagram
(see page 43)
Spare parts
(see page 46)
XXX = Colors
000 = Chrome Plated
800 = Stainless Steel Optic
Special accessories
(order as an extra)
• Adapter (G⅜ / G½)
#93395000 (see page 46)
• extension #43333000
Cleaning
(see page 44)
Operation
(see page 45)
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
• Minor leaking may occur briefly at the spout when
opening the fitting via the lever.
Test certificate
(see page 48)
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping at the threaded base - connection hoses not completely
screwed into basic body
- Tighten connection hoses by hand
- O-ring at the connection hose
defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Summary of Contents for Metris M71 320 1jet 73812 Series
Page 35: ...35 150 6a 6b max 35 mm 3 Nm max 70 mm SW 10 mm SW 19 mm 4 Nm 110 1a 2 1b 3 4 5...
Page 36: ...36 24 x 15 150 6a 75 75 45 105 45 105...
Page 38: ...38 1 SW 22 mm SW 17 mm 8 Nm 2 11 12 1 2 13 14 15 16...
Page 39: ...39 1 2 17 18 max 30 mm max 30 mm max 30 mm 19 20a...
Page 40: ...40 max 20 20b max 20 20c F12 43333000 max 20 20d...
Page 41: ...41 1 Nm A rm at ur en fe tt G re as e 2 min 21 22 23 F12 43333000 max 100 mm 1 2...
Page 45: ...45 1 2 1 2...