4
Assembly see page 31
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
14146000 / 14466000 / 15447XXX / 31451000 /
31487000 / 31646000 / 31946000 / 32477000 /
71407000 / 71474000 / 72406000:
Safety against backflow
The product is exclusively designed for drinking water!
English
Test certificate
(see page 48)
Spare parts
(see page 38)
Symbol description
Maintenance
(see page 36)
14146000 / 14466000 / 15447XXX /
31451000 / 31487000 / 31646000 /
31946000 / 32477000 / 71407000 /
71474000 / 72406000: The safety device
must be checked regularly according to DIN
EN 1717 in accordance with national or
regional regulations (at least once a year).
Fault
Cause
Remedy
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping
-
Cartridge defective
-
Exchange cartridge
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
-
Hot water limiter incorrectly set
-
Set hot water limiter
-
Crossflow
-
Exchange cartridge
Diverter not operating
-
Residue
-
Clean converter / grease O-rings
-
Water pressure to low
-
Increase water pressure
-
Diverter defective
-
Exchange diverter
Do not use silicone containing acetic acid!
Adjustment
(see page 33)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Dimensions
(see page 34)
Flow diagram
(see page 35)
Rate of flow by 0,3 MPa:
Shower outlet
Tub outlet
Operation
(see page 41)
Cleaning
(see enclosed brochure)
Summary of Contents for Logis
Page 31: ...31 2 3 1 Montage X 1 2 mm X 11 2 1 2 1 2 SW 4 mm 5 Nm 5 4 3 01800180...
Page 33: ...33 Justierung Justierung 2 1 3 4 5 6 7 60 C 10 C 0 3 MPa 0 3 0 3...
Page 42: ...42...
Page 43: ...43...
Page 44: ...44...
Page 45: ...45...
Page 46: ...46...
Page 47: ...47...