Safety Notes
Intended Use
This product is designed for use into dry areas of the
bathroom (Zone 3) only.
The entire power is supplied via a 100-240V/N/
PE/50-60Hz AC connection. The circuit must be
protected via a ground fault protector (RCD / FI)
with a measured differential current of ≤ 30 mA.
A different or excessive use is considered non-
intended. The user/operator bears the sole risk.
The intended use includes the adherence to the
operating instructions and the observance of the
inspection and maintenance guidelines.
The manufacturer/seller of this light does not assume
any responsibility for injuries or damage that may be
caused by improper installation or non-intended use.
Electrical installation
Electrician
Installation and tests are to be performed by
an approved electrician, taking VDE 0100, Part
701 into account. It's a Legal Requirement for the
Installation and wiring to conform to current IEE
Electrical and Building regulations.
Electrical connection
Voltage supply: 100-240V/N/PE/50-60Hz
Residual current protection system
The circuit must be protected via a ground fault
protector (RCD / FI) with a measured differential
current of ≤ 30 mA.
The proper function of this protective device must be
checked at regular intervals.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• Gloves should be worn during installation to prevent
crushing and cutting injuries.
• Any work may only be carried out in a de-energized
state. Here, the voltage supply must be safely sepa-
rated via the main switch or mains plugs.
• Only standardized materials may be used for the
installation.
• All components must remain accessible.
• The ambient temperature must not exceed 40 ºC.
• During operation this lamp will get hot. A minimum
distance of 30cm should be maintained, away from
inflammable items.
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel
manufacturer have to be taken into account.
Technical Data
Nominal voltage:
100 - 240 V/N/PE/50 - 60Hz
Power:
max. 2 W
Protection class:
IP 44
Serial number:
73560000 (see typeplate)
Dimensions:
see page 47
weight:
1.380 g