4
English
Assembly
(see page 32)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The diverter (type HC) installed in the bath mixer is
designed as an anti-retraction device. For this reason,
the lower edge of the diverter must be at least
25 mm above the highest possible dirty water level.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Maintenance
(see page 39)
The check valves must be checked regularly according
to EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions
(see page 35)
Flow diagram
(see page 35)
Spare parts
(see page 37)
Cleaning
(see page 40)
Operation
(see page 36)
Test certificate
(see page 40)
Fault
Cause
Remedy
Insufficient water
- check valve hasn't moved back
- Shower filter seal dirty
- Exchange check valves
- Clean filter seal between shower
and hose
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Instantaneous heater didn’t work
- Shower filter seal dirty
- check valve hasn't moved back
- Clean filter seal between shower
and hose
- Exchange check valves
Summary of Contents for Logis Classic 71240000
Page 14: ...14 32 HC 25 1 0 1 0 5 1 6 1 10 bar 147 PSI 60 C 70 C 4 39 EN 806 5 35 35 37 40 36 40...
Page 26: ...26 32 HC 25 1 0 1 0 5 1 6 1 10 bar 147 PSI 60 C 70 C 4 39 EN 806 5 35 35 37 40 36 40...
Page 29: ...29 32 HC 25 1 0 5 0 1 1 6 PSI 147 10 1 60 C 4 70 C 39 5 EN 806 35 35 37 40 36 40...
Page 33: ...33 5 2 min SW 30 mm 17 Nm SW 22 mm 6 7 8 9 10...
Page 34: ...34 SW 22 mm 2 Nm 11...
Page 39: ...1 2 2 1 12 13 14 39...