Concealed installation
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The rotation symmetrical body is horizontal and
vertical usable. Only exception installing the
bath-shower mixer with integrated safety
combination. In this case only a verticaly installation
is possible. Install the iBox always above the
bath-tup. If parts of the iBox will broken, the water
can flow in there!
• The iBox is suitable for both bath and shower
applications. When using the bath-shower mixer /
thermostatic mixer with shut off and diverter unit
outlet, the lower outlet must have priority. For shower
applications, plug the unused outlet with a plug.
• The hot and cold supplies must be of equal
pressures.
• Install body with the hot water supply left and cold
water supply right.
• Depth of fitting: 80 mm to 108 mm.
• extension see installation instructions Finish set
The basic set can depending on the building application
be mounted in different ways, Installation examples
please see page 52 - 53.
A
Direct wall installation.
B
Direct wall installation with 10 mm adjustable
mounting studs.
C
Installation on carrier system.
D
Brick wall installation.
E
Installation with fixation set
Installation examples with measurements and pipe
dimensions can be found starting on page 34.
The installation dimensions stated in these installation
instructions are ideal for people of approximately
1800 mm in body height. The dimensions can be altered
if required. In this case, pay attention to the fact that a
change of installation height will also change the
minimum height, and that the altered mounting
dimensions must be taken into consideration.
Installation tip
• To install the supply pipes, fix the iBox with a pipe in
a vice. (see page 50)
• The spirit level in the iBox is used for rough
alignment, a water scale must be used for precise
alignment. (see page 51)
• Make sure that the sliding sleeve is in the correct
position during assembly. (see page 54)
Flush piping system
(see page 57)
To complete the installation flush out both hot and cold
water supply. The arrows on the flush body show which
inlet is connected to which outlet pipe, e.g. cold water to
the upper outlet and hot water to the lower outlet. If only
one outlet is required, the flush body must be turned 90°
after the first flush.
iBox in combinaton with an Exafill
bath filler with overflow and
waste
(see page 56)
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Centre distance:
R½
Connections:
cold right - hot left
Rate of flow by 0,3 MPa:
Shower mixer:
32 l/min
Thermostatic mixer:
36 l/min
Thermostatic mixer with shut off unit:
26 l/min
Thermostatic mixer HighFlow (Outlet 1 + 2):
58 l/min
Bath-shower mixer:
31 l/min // 24 l/min
Bath-shower mixer with integrated
safety combination:
25 l/min // 24 l/min
Symbol description
Only one function is possible.
If the iBox is soldered, sufficient distance to
the housing must be maintained.
1 2
Assembly
(see page 48)
English
Summary of Contents for iBox universal 2
Page 37: ...37 DN15 DN15 DN15 DN15...
Page 39: ...39 DN15 DN15 DN15 97998000...
Page 40: ...40 2 2 0 0 1000 500 2 4 0 0 12 0 0 10 0 0 200 ShowerSelect Comfort E 2 functions 15572XXX...
Page 41: ...41 DN15 DN15 DN15 DN15...
Page 42: ...42 DuoTurn E 2 functions 75418XXX 200 1000 500 2 4 0 0 10 0 0 12 0 0 1 2...
Page 43: ...43...
Page 45: ...45 DN15 DN15 DN15 DN15 DN15 DN15...
Page 48: ...48 54 59 4 4 49 CL ICK 44 59 SW 8 mm...
Page 49: ...49 11 6 21 16 CL ICK 6 21...
Page 50: ...50 1 2 iBox universal 2 0150018X PU SH CLICK PU SH PU LL...
Page 51: ...51 A B...
Page 52: ...52 B A C...
Page 53: ...53 96615000 D E...
Page 54: ...54 I II III PCI Lastogum PULL PUSH...
Page 55: ...55 CLI CK CLICK IV V PUSH...
Page 56: ...56 1 2 3 4 iBox universal 2 Exafill 300 mm EN 1717 SW 4 mm 4 Nm...
Page 57: ...57 A B 97998000 P P 90 90...
Page 58: ...58...
Page 59: ...59...