3
English
Assembly
(see page 6)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking
water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 8)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Cleaning
(see page 10)
Maintenance
(see page 12)
The check valves must be checked regularly according
to EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions
(see page 4)
Flow diagram
(see page 4)
Spare parts
(see page 13)
Operation
(see page 9)
• Do not rotate the spout further than 360º or damage
to the hose will result.
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping at the threaded
base
- connection hoses not completely
screwed into basic body
- Tighten connection hoses by hand
- O-ring at the connection hose
defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Summary of Contents for Focus M42 180 2jet 71801007
Page 6: ...6 SW 10 mm SW 24 mm 4 Nm 3 Nm 1 2 3b 1 2 max 35 mm max 60 mm 3b 1 2 3a 4 5 6 ...
Page 7: ...7 80 1 CLICK 3 4 2 2 min 1 Nm 7 8 9 10 11 12 ...
Page 9: ...9 开 open 热 hot 冷 cold 关 close ...
Page 10: ...10 Hansgrohe Hansgrohe www hansgrohe int com guarantee QuickClean QuickClean 10 QUICK CLEAN ...
Page 12: ...12 1 1 2 2 ...
Page 14: ...14 ...
Page 15: ...15 ...