• Thermostatic mixer: Operation / Assembly see en-
closed brochure.
Technical Data
Operating pressure:
max. 0,6 MPa
Recommended operating pressure:
0,1 - 0,4 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
English
Assembly see page 32
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using
this product.
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel
manufacturer have to be taken into account.
• The mesh washer must be insert to protect the over-
head shower against incoming dirt by pipework. In-
coming dirt leads to defects or/and can damage parts
of the shower; such caused faults voids all liability and
guarantee claims.
• Optimal functioning is only guaranteed with the com-
bination of Hansgrohe hand showers and Hansgrohe
shower hoses.
• Adjust the dimensions to the tile pattern if required.
Symbol description
Do not use silicone containing acetic acid!
Spare parts
(see page 35)
Dimensions
(see page 31)
Flow diagram
(see page 32)
Operation
(see page 36)
Cleaning
(see page 34) and en-
closed brochure
4
Test certificate
(see page 36)