Technical Data

Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 60°C 

Thermal disinfection: 

70°C ⁄ 4 min

• Safety against backflow
• The product is exclusively designed for drinking 

water!

Symbol description

Do not use silicone containing acetic acid!

Adjustment 

(see page )

To adjust the hot water limiter. Using a hot water limiter 

in combination with a continuous flow water heater is 

not recommended.

Maintenance 

(see page 10)

The check valves must be checked regularly according 

to EN 806-5 in accordance with national or regional 

regulations (at least once a year).

Dimensions 

(see page 9)

Flow diagram 

(see page 9)

Spare parts 

(see page 11)

Cleaning 

(see page 10)

Operation 

(see page 8)

Hansgrohe recommends not to use as drinking water 

the first half liter of water drawn in the morning or after 

a prolonged period of non-use.

Fault

Cause

Remedy

Insufficient water

- Aerator calcified, dirty

- Clean aerator, replace as 

necessary

Mixer stiff

- Cartridge defective, calcified

- Exchange cartridge

Mixer dripping

- Cartridge defective

- Exchange cartridge

Water escaping at the threaded 

base

- connection hoses not completely 

screwed into basic body

- Tighten connection hoses by hand

- O-ring at the connection hose 

defective.

- Exchange O-ring

Hot water temperature too low

- Hot water limiter incorrectly set

- Set hot water limiter

Summary of Contents for Cento XL 2jet 14784000

Page 1: ...EN Instructions for use Assembly instructions 2 DE Gebrauchsanleitung Montageanleitung 3 Cento XL 2jet 14784000...

Page 2: ...cid Adjustment see page To adjust the hot water limiter Using a hot water limiter in combination with a continuous flow water heater is not recommended Maintenance see page 10 The check valves must be...

Page 3: ...Justierung siehe Seite Einstellen der Warmwasserbegrenzung In Verbindung mit Durchlauferhitzern ist eine Warmwassersperre nicht zu empfehlen Wartung siehe Seite 10 R ckflussverhinderer m ssen gem EN 8...

Page 4: ...4 SW 10 mm SW 19 mm 4 Nm 150 110 110 150 max 35 mm 3 Nm max 60 mm 1a 2 3 4 5 1b...

Page 5: ...5 80 mm CLICK CLICK 2 3 1 6 7 8 9 10 11...

Page 6: ...6 2 min 1 Nm A r m a t u r e n f e t t G r e a s e 12 13...

Page 7: ...0 3 MPa 0 3 0 3 60 C 10 C 7 2 1 3 4 5 6 7 4 3 1 2 3 1 2 6 x 36 C 38 C 43 C 50 C 55 C 60 C 17 x S W 4 m m S W 4 m m 5 N m SW 4 mm SW 4 mm...

Page 8: ...8 1 2 open ffnen close schlie en cold kalt hot warm click click 1 2...

Page 9: ...9 click 75 75 1 2 3 4 111 95 74 235 m a x 6 0 20 m a x 5 0 0 411 220 175 8 3 5 34 52 2 3 0 G 3 8 80 Cento XL 2jet 14784000...

Page 10: ...sign com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleanin...

Page 11: ...0 93253000 95507000 95561000 96316000 97523000 92500000 95909000 98459XXX 97735000 97350000 98231000 18x1 5 95910000 98140000 20x1 110 93428000 98162000 44x2 5 98433000 30x1 5 98211000 21x2 5 98396000...

Page 12: ...Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 11 2021 9 07426 03...

Reviews: