Assembly see page 31
Fault
Cause
Remedy
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping
-
Cartridge defective, sedimentation
-
Exchange cartridge
Diverter not operating
-
Residue
-
Clean converter / grease O-rings
-
Water pressure to low
-
Increase water pressure
-
Diverter defective
-
Exchange diverter
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
-
Hot water limiter incorrectly set
-
Set hot water limiter
-
Crossflow
-
Exchange cartridge
Test certificate
(see page 40)
Spare parts
(see page 38)
Cleaning
Cleaning recommendations, see enclosed
brochure.
Maintenance
(see page 36)
11426000 / 12416000 / 18457000
/ 19422000: The safety device must
be checked regularly according to DIN
EN 1717 in accordance with national or
regional regulations (at least once a year).
Operation
(see page 35)
Flow diagram
(see page 34)
Shower outlet
Tub outlet
Dimensions
(see page 34)
To adjust the hot water limiter on single lever
mixers, please see page 33. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
Anti-pollution function
The product is exclusively designed for drinking water!
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
English
4
Summary of Contents for AXOR Urquiola 11425000
Page 31: ...31 Silikon 2 1 2 1 2 3 4 5 6...
Page 32: ...32 Silikon Starck Organic Massaud Bouroullec Urquiola 2 2 2 2 1 1 1 1 3 3 3 4 7 8 9 10a 10b 3...
Page 33: ...33 2 1 3 4 5 6 7 60 C 10 C 0 3 MPa 0 3 0 3...
Page 36: ...36 1 2 2 1 3 4 6 5 SW 2 mm SW 4 mm 4 3 2 1 3 11426000 12416000 18457000 19422000 SW 10 mm...