![Hans Grohe Axor Massaud 18440000 Instructions For Use/Assembly Instructions Download Page 4](http://html.mh-extra.com/html/hans-grohe/axor-massaud-18440000/axor-massaud-18440000_instructions-for-use-assembly-instructions_592955004.webp)
Assembly see page 31
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection
max. 70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking water!
English
Dimensions
(see page 40)
Operation
(see page 34)
Cleaning
(see page 38 and en-
closed brochure)
Symbol description
Spare parts
(see page 41)
Test certificate
(see page 44)
Do not use silicone containing acetic acid!
Flow diagram
(see page 40)
Hand shower
Bath Spout
Maintenance check valve
(see page 36)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Maintenance Secuflex hose
(see page 36)
Repeat cleaning when pull out becomes
difficult.
4
Summary of Contents for Axor Massaud 18440000
Page 31: ...31 13444180 1 2 4 3 5 SW 27 mm SW 3 mm 4 Nm Montage 1 1 1 1 2 3 4 2 2 2 3 ...
Page 32: ...32 1 3 2 2 1 1 2 3 2 1 Silikonspra y 1 2 3 6 10 7 8 9 11 12 ...
Page 33: ...33 1 2 3 4 2 1 14 13 ...
Page 35: ...35 1 2 1 2 3 4 ...
Page 36: ...36 1 3 1 1 2 2 2 DIN DVGW 1 2 3 4 5 3 Wartung ...
Page 37: ...37 Silikonspra y 6 7 1 2 3 8 9 1 2 3 1 3 2 2 1 ...
Page 38: ...38 Reinigung 1 2 3 4 5 6 Torx T15 SW 4 mm 6 Nm SW 4 mm 1 1 2 2 ...
Page 39: ...39 Torx T15 4 Nm 7 8 1 2 3 QUICK CLEAN ...
Page 40: ...40 110 110 110 191 191 15 0 162 116 Maße Durchflussdiagramme 1 2 ...
Page 42: ...42 ...
Page 43: ...43 ...