A S S E M B L Y   (see page 04)

EN

 

S A F E T Y   N O T E S

 

Gloves should be worn during installation to prevent 
crushing and cutting injuries.

 

The product may only be used for bathing, hygienic 
and body cleaning purposes.

 

Do not allow the streams of the shower touch sensitive 
body parts (such as your eyes). An adequate distance 
must be kept between the shower and you.

 

The product may not be used as a holding handle. A 
separate handle must be installed.

 

The hot and cold supplies must be of equal pressures.

I N S T A L L A T I O N   I N S T R U C T I O N S

⁄  Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 
surface damage will be honoured.

⁄  The pipes and the fixture must be installed, flushed and 

tested as per the applicable standards.

⁄  The plumbing codes applicable in the respective 

countries must be observed.

T E C H N I C A L   D A T A
Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

Hot water temperature: 
Recommended hot water temp.: 
Thermal disinfection: 

⁄  Safety against backflow
⁄  The product is exclusively designed for drinking water!

S Y M B O L   D

 

E S C

 

R I

 

P

 

T I O N

 

 

   

Do not use silicone containing acetic acid!

A D J U S T M E N T   (see page 08)

To adjust the hot water limiter. Using a hot water 
limiter in combination with a continuous flow 
water heater is not recommended.
D I M E N S I O N S   (see page 12)

F L O W   D I A G R A M   (see page 12)

Hand shower

Bath Spout

S P A R E   P A R T S   (see page 15)

C L E A N I N G   (see page 10)

O P E R A T I O N   (see page 09)

M A I N T E N A N C E   (see page 13)

The check valves must be checked regularly 
according to DIN EN 1717 in accordance with 
national or regional regulations (at least once a 
year).

(1 MPa = 10 bar = 147 PSI) 

max. 70°C 

65°C 

70°C / 4 min

Summary of Contents for AXOR Edge 46432009

Page 1: ...I N S T A L L A T I O N E N Instructions for use assembly instructions 02 D E Gebrauchsanleitung Montageanleitung 03 AXOR Edge 46432009 ...

Page 2: ...s The plumbing codes applicable in the respective countries must be observed T E C H N I C A L D A T A Operating pressure max 1 MPa Recommended operating pressure 0 1 0 5 MPa Test pressure 1 6 MPa Hot water temperature Recommended hot water temp Thermal disinfection Safety against backflow The product is exclusively designed for drinking water S Y M B O L D E S C R I P T I O N Do not use silicone ...

Page 3: ...tiert gespült und geprüft werden Die in den Ländern jeweils gültigen Installationsrichtlini en sind einzuhalten T E C H N I S C H E D A T E N Betriebsdruck Empfohlener Betriebsdruck Prüfdruck Heißwassertemperatur Empfohlene Heißwassertemperatur Thermische Desinfektion Eigensicher gegen Rückfließen Das Produkt ist ausschließlich für Trinkwasser konzi piert S Y M B O L E R K L Ä R U N G Kein essigsä...

Page 4: ...0 4 15487187 1 2 SW 17 mm 3 SW 30 mm 4 5 1 3 SW 24 mm 14 Nm 1 2 2 ...

Page 5: ...0 5 3 1 1 6 7 2 2 3 8 SW 27 mm 9 10 11 SW 3 mm 4 Nm SW 3 mm 4 Nm 2 SW 3 mm 4 Nm 1 1 2 3 4 ...

Page 6: ...0 6 13 14 16 15 1 2 3 1 5 Nm 1 2 5 6 4 12 1 2 3 ...

Page 7: ...0 7 1 2 3 19 18 17 ...

Page 8: ...0 8 60 C 10 C 0 3 MPa 6 5 3 4 36 C 38 C 43 C 60 C 55 C 50 C 1 2 SW 3 mm 4 x SW 3 mm 5 Nm ...

Page 9: ...0 9 max 1 45 m 1 2 close schließen open öffnen hot warm cold kalt ...

Page 10: ...r design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation w w w axor design com cleaning recommendation E N Cleaning recommendation Warranty Cont...

Page 11: ...11 3 5 6 1 min 2 1 4 ...

Page 12: ... 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec 1 2 AXOR Edge 46432009 1 2 44 72 72 108 72 60 216 110 190 33 230 210 230 266 65 172 145 ...

Page 13: ...1 3 1 2 2 1 3 4 5 6 1 2 ...

Page 14: ...1 4 7 8 10 1 2 3 11 9 ...

Page 15: ...3x2 5 98185000 22x2 93629000 93583000 93585000 93589000 93592000 97660000 93590000 93587000 98447000 95704000 95704000 95704000 M6x8 98388000 24x2 98193000 32x2 98200000 52x1 5 96942000 94246000 93582000 93591000 93506000 96456000 93185000 95008000 AXOR Edge 46432009 93339000 ...

Page 16: ...AXOR Hansgrohe SE Auestraße 5 9 77761 Schiltach Deutschland info axor design com axor design com 12 2020 9 06723 61 ...

Reviews: