A S S E M B L Y (see page 35)
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
Children as well as adults with physical, mental and⁄or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ In order to protect the showerpipe from damage caused by frost, the lines have to
be laid in such a way that they can be emptied up to the frost-free area.
⁄ If there is a risk of frost: In order to protect the showerpipe from damage caused by
frost, the lines have to be laid in such a way that they can be emptied up to the
frost-free area. (see page 38)
⁄ During winter storage: The product have to be completely dismantled and stored in
a dry place. All components must no longer contain water. (see page 39)
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ The mesh washer must be insert to protect the shower against incoming dirt by
pipework. Incoming dirt leads to defects or⁄and can damage parts of the shower;
such caused faults voids all liability and guarantee claims.
⁄ The product is not designed to be used with steam baths!
⁄ During installation of the product by qualified trained personnel, make sure that the
entire fastening surface is even and smooth (no protruding seams or tile offset), that
the finish of the wall is suitable to apply the product and has no weak points.
⁄ The arm of the shower head is intended only to hold the shower head. Do not load
it down with other objects!
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Connections G 1⁄2:
cold right - hot left
Thermal disinfection:
70°C ⁄ 4 min
⁄ Safety against backflow
⁄ The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 36)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
M A I N T E N A N C E (see page 36)
⁄ The check valves must be checked regularly according to EN 806-5 in
accordance with national or regional regulations (at least once a year).
⁄ To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
D I M E N S I O N S (see page 37)
F L O W D I A G R A M (see page 37)
I N S T A L L A T I O N E X A M P L E (see page 45)
S P A R E P A R T S (see page 46)
XXX = Colors
000 = Chrome Plated
140 = Brushed Bronze
250 = Brushed Gold-Optic
300 = Polished Redgold
310 = Brushed Redgold
330 = Polished Black Chrome
340 = Brushed Black Chrome
670 = Matt Black
800 = Stainless Steel Optic
820 = Brushed Nickel
950 = Brushed Brass
990 = Polished Gold-Optic
S P E C I A L A C C E S S O R I E S (order as an extra)
extension 80 mm #13608000 (see page 46)
C L E A N I N G (see page 43)
D I S M O U N T I N G
If there is a risk of frost (see page 38)
During winter storage (see page 39)
R E T U R N T O S E R V I C E
When there is no more a risk of frost (see page 40
After winter storage (see page 41)
O P E R A T I O N (see page 42)
To empty the overhead shower after use, hold it in a slightly inclined position.
T E S T C E R T I F I C A T E (see page 36)
i
S u m
m
e
r
F A U L T
C A U S E
R E M E D Y
⁄ Insufficient water
⁄ Supply pressure inadequate
⁄ Check water pressure (If a pump has been installed check
to see if the pump is working).
⁄ Regulator filter dirty
⁄ Clean filter in front of the mixer and on the MTC-thermo car-
tridge
⁄ Shower filter seal dirty
⁄ Clean filter seal between shower and hose
⁄ Crossflow, hot water being forced into cold water pipe, or
vice versa, when mixer is closed
⁄ Backflow preventers dirty or leaking
⁄ Clean backflow preventers, exchange if necessary
⁄ Instantaneous heater didn't work with thermostat
⁄ Filters are dirty
⁄ check valve hasn't moved back
⁄ Flow limiter in handshower isn’t removed
⁄ Spray former calcified, dirty
⁄ Exchange check valves
⁄ Remove flow limiter