Abbreviations 14

13.  ABBREVIATIONS

NBR

 

Nitrile Butadiene Rubber

NPT

 

American National Pipe Standard Taper Pipe Thread

PTFE

 Polytetrafluoroethylene

PVC

 

Polyvinyl Chloride

PVDF

  Polyvinylidene Fluoride

CERTIFICATION

All Hanna

®

 instruments conform to the 

CE European Directives.

Disposal of Electrical & Electronic Equipment.

 The product should not be treated as household waste. Instead, 

hand it over to the appropriate collection point for the recycling of electrical and electronic equipment, which 
will conserve natural resources. Ensuring proper product disposal prevents potential negative consequences for 
the environment and human health.
For more information, contact your city, your local household waste disposal service, or the place of purchase.

RECOMMENDATIONS FOR USERS

Before using this product, make sure it is entirely suitable for your specific application and for the environment 
in which it is used. Any variation introduced by the user to the supplied equipment may degrade its performance.
Do not use or store the product in hazardous environments.

WARRANTY

The probes are warrantied for six months against defects in workmanship and materials when used for its 
intended purpose and maintained according to instructions. This warranty is limited to repair or replacement 
free of charge. Damage due to accidents, misuse, tampering, or lack of prescribed maintenance is not covered.
If service is required, contact your local Hanna Instruments

®

 office. If under warranty, report the model number, 

date of purchase, serial number, and the nature of the problem. If the repair is not covered by the warranty, you 
will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain 
a Returned Goods Authorization (RGA) number from the Technical Service department and then send it with 
shipping costs prepaid. When shipping any product, make sure it is shipped back in compliance with shipping 
regulations, thoroughly cleaned and free of any chemicals, and is properly packaged for complete protection.

MAN10X6-8 07/22

Summary of Contents for HI1006-18

Page 1: ...rature Industrial Smart Probes SN XXXXXXXXXXXX pH 0 12 T 5 to 80 C p max 6 bar HI1006 1805 SN XXXXXXXXXXXX pH 0 12 T 5 to 80 C p max 6 bar HI1006 1800 Please scan the QR code or follow the link to dow...

Page 2: ...ssories 13 13 Abbreviations 14 Certification 14 Recommendations for Users 14 Warranty 14 Dear Customer Thank you for choosing a Hanna Instruments product Please read this instruction manual carefully...

Page 3: ...trial pH probes intended for industrial process control when teamed up with the HI510 Universal Process Controller HI1006 18 and HI1016 18 series designed for low conductivity or low temperature proce...

Page 4: ...uoride resistant HF glass sensor titanium matching pin 5 0 to 60 0 C 23 0 to 140 0 F 0 00 to 10 00 pH 8 Smart probe with RS485 connection zz 00 supplied with DIN connector without cable See Accessorie...

Page 5: ...controller setting Temperature compensation Automatic 0 0 to 80 0 C 32 0 to 176 0 F Temperature source Automatic from Probe Manual Body PVDF Junction PTFE Sensor Body LT glass Tip shape flat self cle...

Page 6: ...ations Probes are easily installed using the 3 4 NPT external thread Hand tighten the probe in position Then depending on the process tighten one or two turns with a wrench to secure in place Do not e...

Page 7: ...quire that saddle and flow cell are completely filled with water In line mounting with probe saddle 1 2 4 3 5 Note Probe can be rotated to prevent air entrapment inside the electrode Mounting accessor...

Page 8: ...enance and replacement B Slide out the electrode holder cap 3 C Screw the probe into the internally threaded protective cap 9 step I D Screw the probe and protective cap subassembly onto the holder 5...

Page 9: ...sediment or other foreign material to accumulate within the sensing area TANK VALVE 1 VALVE 2 FLOW FLOW INCOMING FLOW EXIT FLOW 3 1 2 4 5 7 6 6 FLOW CELL 1 Process controller 2 Wiring cable 3 pH prob...

Page 10: ...tor and attach ground lead g COMM B A IN1 IN2 A01 A02 A03 A04 PROBE B A PROBE B A A B Probe cabling color code Marking Attached cable Patch cable Functionality GREEN BLACK 0V B WHITE WHITE RS485 D A Y...

Page 11: ...CFM to save Wait followed by Calibration point is accepted and saved is displayed after the calibration point has been saved and accepted 5 Select Next to continue with a two point calibration 6 Repea...

Page 12: ...ubbles inside the glass bulb If the bulb and or junction are dry soak the electrode in HI70300 Storage solution for at least 30 minutes To ensure a quick response time the glass bulb and the junction...

Page 13: ...L Oil and fat cleaning solution 230 or 500 mL Other Accessories HI60501 PVC immersion electrode holder HI60503 PVDF immersion electrode holder HI60501 0 O rings for HI60501 electrode holder HI605011 P...

Page 14: ...roduced by the user to the supplied equipment may degrade its performance Do not use or store the product in hazardous environments WARRANTY The probes are warrantied for six months against defects in...

Reviews: