background image

Proper Use of Minipipette

• Attach the pipette tip.
• Press the button down to the first stop.
• Immerse the pipette tip in the liquid approximately 2-3 mm.
• Slowly let the button move back to the original position, wait 2 seconds.
• Remove the pipette tip from the liquid.
• To dispense the liquid, place the pipette tip on the inside wall of the container.
• Slowly press the button down to the first stop.
• Wait until all of the liquid has been dispensed.
• Press the button down to the second stop, this will allow any remaining liquid 

to be dispensed.

Tips for an Accurate Measurement

• Ensure the sample does not contain any debris.
• Whenever the cuvette is placed into the checker, it must be dry 

outside and free of fingerprints, oil and dirt. 

• Wipe the cuvette thoroughly with 

HI731318

 microfiber 

cleaning cloth or a lint-free cloth prior to insertion.

• Shaking the cuvette can generate bubbles, causing higher 

readings. To obtain accurate measurements, remove such 
bubbles by swirling or by gently tapping the cuvette.

• Do not let the reacted sample stand too long after reagent has 

been added, as accuracy will be affected.

• Discard the sample immediately after the reading has been taken 

or the glass might become permanently stained.

Battery Replacement

To save the battery, the checker shuts down after 10 minutes of non-use and 
2 minutes after reading.
A fresh battery lasts for a minimum of 5000 measurements. When the battery is 
drained, the instrument displays “bAd” then ”bAt”, and turns off. 
To replace the battery, follow the next steps:
1. Press and hold the ON/OFF button to turn the checker off.
2. Turn the instrument upside down and use a 

screwdriver to unfasten the screw and remove 
the battery cover.

3. Remove the old battery, replace it with a new 

1.5V AAA battery, inserting the negative end 
first.

4. Replace the battery cover, fasten and tighten 

the screw.

Accessories

Reagent Sets

HI758-26

Reagents for 25 Marine Calcium tests

Other Accessories

HI758-11

Marine Calcium certified standard kit

HI70436M

Deionized water (230 mL)

HI731315

Glass cuvette and cap for Checker

®

 HC colorimeters (2 pcs.)

HI731318

Cloth for wiping cuvettes (4 pcs.)

HI731339P

0.1 mL minipipette

HI731349P

Tip for 0.1 mL minipipette (10 pcs.)

HI740028P

1.5V AAA battery set (12 pcs.)

HI93703-50

Cuvette cleaning solution, 230 mL

Certification

All Hanna Instruments conform to the 

CE European Directives.

Disposal of Electrical & Electronic Equipment.

 The product 

should not be treated as household waste. Instead hand it over 

to the appropriate collection point for the recycling of electrical 

and electronic equipment which will conserve natural resources.

Disposal of waste batteries.

 This product contains batteries, do 

not dispose of them with other household waste. Hand them over 

to the appropriate collection point for recycling.

Ensuring proper product and battery disposal prevents potential negative 

consequences for the environment and human health. For more information, 

contact your city, your local household waste disposal service, the place of 

purchase or go to 

www.hannainst.com

.

Recommendations for Users

Before using this product, make sure it is entirely suitable for your specific 

application and for the environment in which it is used. Any variation introduced 

by the user to the supplied equipment may degrade the checker’s performance. For 

yours and the checker’s safety do not use or store it in hazardous environments.

Warranty

HI758

 Checker

®

HC is warranted for a period of one year against defects in 

workmanship and materials when used for its intended purpose and maintained 

according to instructions. This warranty is limited to repair or replacement free 

of charge. Damage due to accidents, misuse, tampering or lack of prescribed 

maintenance is not covered. If service is required, contact your local Hanna Instruments 

Office. If under warranty, report the model number, date of purchase, serial number 

and the nature of the problem. If the repair is not covered by the warranty, you will be 

notified of the charges incurred. If the checker is to be returned to Hanna Instruments, 

first obtain a Returned Goods Authorization (RGA) number from the Technical Service 

department and then send it with shipping costs prepaid. When shipping any product, 

make sure it is properly packaged for complete protection.

Hanna Instruments reserves the right to modify the design, construction, or 

appearance of its products without advance notice.

All rights are reserved. Reproduction in whole or in part is prohibited without the written 

consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 

02895, USA.

IST758 06/20

HI758

Marine Calcium

INSTRUCTION MANUAL

Summary of Contents for HI 758

Page 1: ...HI758 Marine Calcium INSTRUCTION MANUAL ...

Page 2: ...is delivered in a case with custom insert and is supplied with Sample cuvette and cap 2 pcs Marine Calcium reagent starter kit reagents for 25 tests 1 mL syringe with tip 1 pc Minipipette with tip 1 pc Plastic pipette 1 pc 1 5V AAA Alkaline battery 1 pc Instruction manual Note Save all packing material until you are sure that the Checker HC handheld colorimeter works correctly Any damaged or defec...

Page 3: ...thod Adaptation of the Zincon Method Environment 0 to 50 C 32 to 122 F max 95 RH non condensing Battery type 1 5V AAA Alkaline Auto shut off After 10 minutes of non use and 2 minutes after reading Dimensions 86 0 x 61 0 x 37 5 mm 3 4 x 2 4 x 1 5 Weight 64 g 2 3 oz Functional Description LCD Display Cap Cuvette with cap Cuvette holder LCD Liquid Crystal Display ON OFF button ...

Page 4: ...ap Press the ON OFF button When the display shows Add C2 with Press blinking the checker is zeroed Remove the cuvette and unscrew the cap Use the minipipette and add 0 1 mL of sample to the cuvette Add the content of 1 packet of HI7582 Marine Calcium reagent B Replace the cap and shake vigorously for 15 seconds or until the powder is completely dissolved Allow air bubbles to dissipate for 15 secon...

Page 5: ...zero cuvettes are inverted Swap the cuvettes and repeat the measurement Under Range A blinking 200 indicates that the sample absorbs less light than the lower range limit Check the measurement procedure and make sure to use the same cuvette for reference zero and measurement Over Range Maximum concentration value displayed blinking indicates the measured value is outside the limits of the method V...

Page 6: ...y remaining liquid to be dispensed Tips for an Accurate Measurement Ensure the sample does not contain any debris Whenever the cuvette is placed into the checker it must be dry outside and free of fingerprints oil and dirt Wipe the cuvette thoroughly with HI731318 microfiber cleaning cloth or a lint free cloth prior to insertion Shaking the cuvette can generate bubbles causing higher readings To o...

Page 7: ...ten the screw and remove the battery cover 3 Remove the old battery replace it with a new 1 5V AAA battery inserting the negative end first 4 Replace the battery cover fasten and tighten the screw Accessories Reagent Sets HI758 26 Reagents for 25 Marine Calcium tests Other Accessories HI758 11 Marine Calcium certified standard kit HI70436M Deionized water 230 mL HI731315 Glass cuvette and cap for ...

Page 8: ...ours and the checker s safety do not use or store it in hazardous environments Warranty HI758 Checker HC is warranted for a period of one year against defects in workmanship and materials when used for its intended purpose and maintained according to instructions This warranty is limited to repair or replacement free of charge Damage due to accidents misuse tampering or lack of prescribed maintena...

Reviews: