background image

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

 Instruction Manual

www.hannainst.com

Dear Customer,
Thank you for choosing a Hanna Product.
Please read the instruction sheet carefully before using the
test kit. It will provide you with the necessary information

for correct use of the kit. If you need additional information,
do not hesitate to e-mail us at [email protected].
Remove the chemical test kit from the packing material and
examine it carefully to make sure that no damage has
occurred during shipping. If there is any noticeable dam-
age, notify your Dealer or the nearest Hanna office
immediately.
Each kit is supplied with:

• HI 93718-0 Reagent, packets (100 pcs);
• 1 color comparator cube;
• 1 plastic pipette (3 mL).

Note:

Any damaged or defective item must be returned in
its original packing materials.

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

HI 3879

Iodine

Test Kit

ISTR3879     10/00    PRINTED IN ITALY

Range

0 to 5 mg/L (ppm)

Smallest Increment

1 ppm

Analysis Method

Colorimetric

Sample Size

5 mL

Number of Tests

100

Case Dimensions

230x60x68 mm (9.0x2.4x2.7")

Shipping Weight

143 g (5.0 oz.)

SIGNIFICANCE AND USE

SIGNIFICANCE AND USE

SIGNIFICANCE AND USE

SIGNIFICANCE AND USE

SIGNIFICANCE AND USE

The disinfectant properties of iodine have led to its use as

an alternative to chlorine and bromine.
However, its toxic and corrosive properties and the difficulties

of dissolving it in water has limited a more wide-spread
application. One of its most common application is in
poultry industry process water.

Note:

 mg/L is equivalent to ppm (parts per million).

INSTRUCTIONS

INSTRUCTIONS

INSTRUCTIONS

INSTRUCTIONS

INSTRUCTIONS

The chemicals contained in this kit may be hazardous if
improperly handled. Read the relevant Health and Safety
Data Sheet before performing this test.

HEALTH AND SAFETY

HEALTH AND SAFETY

HEALTH AND SAFETY

HEALTH AND SAFETY

HEALTH AND SAFETY

REFERENCES

REFERENCES

REFERENCES

REFERENCES

REFERENCES

Adaptation of the 

Standard Methods for the Examination

of Water and Wastewater

, 18th edition, DPD method.

READ THE ENTIRE INSTRUCTIONS BEFORE USING THE KIT

• Fill the color comparator cube with

5 mL of sample (up to the mark).

• Add 1 packet of HI 93718-0 reagent, replace the cap

and shake well.

• Wait for 2 minutes to allow color

to develop.

• Determine which color matches the solution in the vessel

and record the result as mg/L (or ppm) of Iodine.

Note:

 It is better to match the color with a white sheet

placed at about 10 cm (4") behind the comparator.

5 mL

10 cm

The reaction between iodine and the reagent causes a
reddish tint in the sample. The amount of color developed is
proportional to the concentration of iodine present in the

aqueous sample.

CHEMICAL REACTION

CHEMICAL REACTION

CHEMICAL REACTION

CHEMICAL REACTION

CHEMICAL REACTION