background image

HyperVAC

HVC-2124 / HVC-2200

Product Model Name :

Date of Purchase :

User Manual

Summary of Contents for HyperVAC HVC-2124

Page 1: ...HyperVAC HVC 2124 HVC 2200 Product Model Name Date of Purchase User Manual...

Page 2: ...s subject to partial change for improvement If you have any questions contact our Technical Support Center 82 2 3452 8966 techsupport ihanil com www ihanil com Manufacturer Hanil Scientific Inc B2 5F...

Page 3: ...y Lid Release 12 3 6 Installing Removing the Rotor 13 3 7 Positioning of Sample Tubes 14 4 Operation 15 4 1 Key Functions of Control Panel 15 4 2 Setting the RPM 17 4 3 Setting the Time 17 4 4 Setting...

Page 4: ...care Keep this manual nearby for future reference The labels on the device represent safety instructions and directions 1 1 Using this manual 1 2 Safety Labels on the Device Indicate a hole for manual...

Page 5: ...060 hPa 4 Before connecting the power check the rated voltage 5 Should not use unapproved rotors and accessories Only use rotors from Hanil Scientific Inc with appropriate centrifugal tubes to embrac...

Page 6: ...ulations Do not place dangerous materials within 30 cm distance around the device Use the emergency lid release function only when the lid button on the control panel is dumb under the condition of co...

Page 7: ...Technical Support 82 2 3452 8966 techsupport ihanil com 7 29 2 Product Description 2 1 Product Description HVC 2124 HVC 2200...

Page 8: ...8 29 2 Product Description 2 2 Delivery Package Check all parts for damage that may have occurred during transportation Check the delivery for completeness Hyper VAC 2124 2200 AC Power cable Emergenc...

Page 9: ...g Time 23 hr 59 min or continuous Default value 0 h 0 m continuous 23 hr 59 min or continuous Default value 0 h 0 m continuous Centrifuge Dimension W x D x H mm 375 x 445 x 252 475 x 560 x 350 Weight...

Page 10: ...ency Lid Release on the left side of the main body Remove the protection material inside the main body Vacuum Concentrator series are delivered with the basic rotor mounted and the protection material...

Page 11: ...is closed Lid LED turns off Close the lid until hearing clank shut When the lid is open the lid LED turns on The lid is not released while the device is running With the vacuum pump connected the lid...

Page 12: ...ase Tool through the Opening for Emergency Lid Release 1 Find the Opening for Emergency Lid Release on left side of the device 2 Insert Emergency Lid Release Tool into the opening and push it until th...

Page 13: ...Rotor 1 Before installing a rotor clean the motor shaft and chamber with soft dry towel 2 Load a rotor into the motor shaft Lock it with the Locking Nut To install the rotor Rotate the locking nut cl...

Page 14: ...ould be placed in the rotor with equal amount of samples at symmetrical positions Only use appropriate centrifugal tubes and do not exceed the speed beyond the max g force allowed for the tubes If it...

Page 15: ...values or recall the saved parameters Saving capacity max 100 memories Use to confirm the parameter setting Check the preset values during operation Use to start or stop operation Use to open the dev...

Page 16: ...en the machine is not operating Normally adjustment of the Sub Display is not used for operation but for Emergency Lid Release in any emergency conditions The detailed method sequence for the Emergenc...

Page 17: ...omplete the setting Time is counted down after starting centrifugation 1 Press the button once 2 Press the or button to change input value and then press the button to complete the setting Speed setti...

Page 18: ...ng 4 Operation 4 5 Saving a Program 4 6 Calling up a Program 4 7 Start Stop 1 To recall the saved program press the button shortly less than 1 sec Check the message of PROGRAM CALL on the display wind...

Page 19: ...fore the chamber reaches to the set temperature If you want to start the operation at your set temperature you can use the PRE HEAT function Press the button before pressing the button Then the operat...

Page 20: ...open the release has to be set as ON 6 When the vacuum release is completed alarm beeps and Lid LED blinks for 5 seconds 7 Press the button and open the lid within 5 seconds while the Lid LED blinks 4...

Page 21: ...he scratches can cause corrosion on the surface of the device If any rust is found on the vacuum pump clean it with neutral detergents and keep it dry 5 Maintenance 5 1 Outer Part of Device 5 2 Chambe...

Page 22: ...ace of rotors Any small scratches can cause corrosion of the rotor and big damage to the device 3 While the device is not used keep the rotor separated from the motor shaft 1 If you need to move or sh...

Page 23: ...r is out check the main fuse for the laboratory to supply the power If it is not solved shortly open the lid with emergency lid tool manually for safety of sample Refer to 3 5 Emergency Lid Open Can t...

Page 24: ...ended this message may appear Turn off the main power and check the voltage of the Power supply V Hz Use AVR to provide proper power Error 5 High Voltage If the input power V Hz is at least 10 more th...

Page 25: ...el Error 10 Motor It cannot recognize the motor Please contact us 6 2 Error Codes Any wire disconnection or tuning of the device must be performed only by a service engineer who is authorized by Hanil...

Page 26: ...0 mL 0 5 mL 48 x 1 5 2 0 mL 76 x 0 5 mL 11 1 8 HRV m2 0 120 1 5 2 0 mL 120 x 1 5 2 0 mL 11 1 HRV 50 6 Incl 6 ea x HLV 50 50 mL 50mL Conical HLV 50 HLV 50c 6 x 50 mL 6 x 50 mL conical 30 4 x 101 HRV 1...

Page 27: ...Trap Tube Plate Type Max Tube Capacity HRV 10 18 10 mL 18 x 10 mL vial tube HRV 10 32 10 mL 32 x 10 mL HRV 15c 12 15 mL conical 12 x 15 mL conical HRV 20 12 20 mL 12 x 20 mL vial tube HRV 50c 6 Micro...

Page 28: ...Diameter mm HRV m2 0 200 1 5 or 2 0 mL 0 5 mL 48 x 1 5 2 0 mL 76 x 0 5 mL 11 1 8 HRV 15 48 Incl 48 ea x HLV 15 15 mL HLV 15 48 x 15 mL 18 x 93 HRV 50 12 Incl 12 ea x HLV 50 15 mL HLV 15 12 x 15 mL 18...

Page 29: ...Ordering Information Cooling Trap Tube Plate Type Sleeve HRV 5 192 5 mL 192 x 5 mL HRV 8 60 8 mL 60 x 8 mL vial tube HRV 15c 24 15 mL Conical 24 x 15 mL conical HRV 30 24 30 mL 24 x 30 mL vial tube H...

Page 30: ...MEMO...

Page 31: ......

Page 32: ...RECYCLABLE...

Reviews: