background image

13

Available functions 

with search-index (a-i)

a)  Resetting of the stop watch

b)  Changing the MODE (function) 

c)  Measurement of time periods  

d) Event-Counter

e)  Pre-setting of the Split-Time

f)  Memory Recall with Quick Recall and evaluation 

g) Countdown 

h)  Pacer E 200

i)  Setting of the time, date, CD, Pacer and measuring units

a)  Resetting the watch

  By pressing the START/STOP and MODE keys at the same time, all  

  times and values are erased from the memory. Date and Time of Day  

  remain in memory. The display in the function window then shows  

 LAP.

b)  MODE 

(Changing functions):

  By pressing the MODE key, the functions will be changed in the  

  versions indicated in the following sequences:

  E 200 

LAP

 

 S-LAP 

➤ 

TIME 

➤ 

DATE 

 CD 

 PACER

  and back to LAP

 Spectron  LAP 

 S-LAP 

 TIME 

 DATE 

 CD 

 empty

  and back to LAP

 

  The active function is indicated in the function window. The times and  

  values corresponding to these functions are shown in the upper row  

  of the display, as follows:

  LAP: 

Lap Time 

6 digits  

  S-LAP:   

Lap or Short Time    

6 digits 

  TIME:    

Time of day: 

23:45,59

  DATE:   

Date (Europe)        

01.01.08 (01. Jan. 2008)

   

(USA) 

01.01.08 (01. Jan. 2008)

14

  Additionally for DELTA E 200

  PACER: 

signals/min 

3 digits

   

50 ms accuracy

  CD: 

Countdown 

5 digits

   

1/10 sec-accuracy

  Additionally for SPECTRON:

  CD: 

Countdown 

5 digits

   

1/10 sec-accuracy 

 LEER: 

Switch 

min/sec

  Normally, the Split Time is shown in the lower row of the display. 

 

A note on LAP, S-LAP und TIME

  Once the watch has been started and the time is being measured, a  

  selection can be made only from among these three functions.

 

A note on Countdown

  After a start, it is not possible to change the Mode. However, virtually  

  the same time measurement can be completed with START/STOP and  

  SPLIT/LAP (see CD function).

 
 

A note on PACER

  After a start, it is not possible to change the Mode. However, the total  

  time is measured and the START/STOP function remains operative  

  (see Pacer function).

c) Measuring times

-  Select the one of the function LAP, S-LAP or TIME by means of the  

  MODE key.

-  The stopwatch starts by means of the START/STOP key. Time measu- 

  rement begins and is visible while in operation. The figure   

  (a running man) indicates this condition.

  By pressing the START/STOP key again, Split Time and Countdown  

  stop. This sequence can be repeated as often as desired.

-  By pressing the SPLIT/LAP key, the Split Time and Lap Time values  

  will be stored in memory at that moment.

Summary of Contents for DELTA E 200 SPECTRON

Page 1: ...INSTRUCTION BOOK GUARANTEE DELTA E 200 SPECTRON...

Page 2: ...d to get it repaired or exchanged free of charge Defects resulting from abuse of the stop watch are not covered by this guarantee for instance if contact springs are corroded by batteries which have l...

Page 3: ...100 sek SPECTRON 1 100 sek 1 100 min 1 Speicher 65 Funktionen Start Stop Split Lap Short Lap Time Memoryabruf mit Schnelllauf und Auswertung der k rzesten und l ngsten LAP Zeit CD Count Down Zus tzlic...

Page 4: ...ufl sung zus tzlich bei SPECTRON CD Count Down 5 Digit 1 10 sek Aufl sung LEER Umschalten min sek In der unteren Displayreihe wird prinzipiell die Splitzeit angezeigt Speziell zu LAP S LAP und TIME Is...

Page 5: ...eint im Display au erden das Symbol SHORT 6 Zus tzlich h ren Sie ein akustisches Signal f r die k rzeste Lapzeit mit der Folge 100 ms Signalton 400 ms Pause Entspricht die angezeigte Lapzeit der l ngs...

Page 6: ...t Taste MODE verl sst den Set Zustand ohne Weiterschalten zum n chsten MODE 8 Datum einstellen 6 Digit Europa Version tt mm jj USA Version mm dd yy Mit MODE Taste auf DATE Funktion Taste SET aktiviert...

Page 7: ...20 24 25 30 40 50 60 75 80 100 120 150 200 240 300 10 SPECTRON Aufl sung 1 100 min oder 1 100 sek Mit der MODE Taste bis das Funktionsfeld leer ist Das Symbol SET ist aktiviert Mit der Taste SET wird...

Page 8: ...1 100 sec SPECTRON 1 100 sec 1 100 min 11 Memories 65 Functions Start Stop Split Lap Short Lap Time Memory Recall with evaluation of the shortest and longest LAP Time CD Count Down Additionally for DE...

Page 9: ...1 08 01 Jan 2008 14 Additionally for DELTA E 200 PACER signals min 3 digits 50 ms accuracy CD Countdown 5 digits 1 10 sec accuracy Additionally for SPECTRON CD Countdown 5 digits 1 10 sec accuracy LEE...

Page 10: ...ng the DISP MEM key again the time stored in the next memory will be displayed and so forth If the time displayed is the shortest Lap Time recorded the symbol SHORT is also displayed You will hear a t...

Page 11: ...To terminate the Set procedure press the MODE key this immediately advances the display to the next MODE 18 Setting the date 6 digits Europe version dd mm yy US version mm dd yy Press MODE until the...

Page 12: ...12 15 16 20 24 25 30 40 50 60 75 80 100 120 150 200 240 300 20 SPECTRON Measurement Units 1 100 min or 1 100 sec Press the MODE key until the function field of the display is empty The symbol SET is a...

Page 13: ...ECTRON 1 100 sec 1 100 min 21 M moires 65 Fonctions Start Stop Split Lap Short Lap heure date rappel m moire et valuation du temps LAP plus court et plus long CD Count Down Fonctions suppl mentaires D...

Page 14: ...iffres TIME Temps de l heure 23 45 59 DATE Date Europe 01 01 08 01 Jan 2008 Date USA 01 01 08 01 Jan 2008 24 Fonctions suppl mentaires DELTA E 200 PACER coups min 3 chiffres 50 ms unit s de mesure CD...

Page 15: ...nt que la touche reste press e Pendant cette phase le symbole M OUT est affich Dessous appara t la m moire appel e 26 Par nouvelle pression de la touche DISP MEM la m moire suivante est affich e et ai...

Page 16: ...cette op ration est n cessaire CD et PACER doivent tre introduits avant d part Le symbole SET est active imm diatement pour introduction 28 Introduction de l heure 4 chiffres hh mm Presser la touche...

Page 17: ...es Entered Becomes 1 36 1 1 54 55 54 97 104 100 37 38 56 58 57 105 115 110 38 41 1 1 59 61 60 116 127 120 42 43 42 62 64 63 128 139 135 44 45 44 65 68 66 140 159 150 46 47 46 69 73 70 160 190 175 48 4...

Page 18: ...luzione temporale DELTA E 200 1 100 sec SPECTRON 1 100 sec 1 100 min 31 Memorie 65 Funzioni Start Stop Split Lap Short Lap Time Richiamo memorie con il tempo LAP maggiore e minore CD Count Down Supple...

Page 19: ...8 34 in aggiunta per DELTA E 200 PACER colpi min 3 cifre scomposizione 50 ms CD Count Down 5 cifre scomposizione 1 10 sec in aggiunta per SPECTRON CD Count Down 5 cifre scomposizione 1 10 sec VUOTO co...

Page 20: ...36 E cos via Il valore del tempo Lap evidenziato dal simbolo SHORT corrisponde al pi breve tempo Lap rilevato Il maggiore tempo Lap viene indicato da un segnale acustico con le seguenti caratteristic...

Page 21: ...e MODE si cambia funzione 38 Inserimento data 6 cifre Versione Europa gg mm aa Versione USA mm dd yy Premere il pulsante MODE sino alla funzione DATE Il pulsante SET attiva lo svolgimento di SET facen...

Page 22: ...150 200 240 300 40 SPECTRON Scomposizione 1 100 min oppure 1 100 sec Agire sul pulsante MODE sino a quando il campo delle funzioni risulti vuoto Appare il simbolo SET Con il pulsante SET si commuta l...

Page 23: ...Hanhart 1882 GmbH Uhrenmanufaktur Hauptstra e 33 78148 G tenbach Germany www hanhart com...