Exsamples of the application
Thank you for choosing GSM - remote-controlled
contact- and surveillance device. Connected to the thermostat
HandyHeat131 it controls the electrical heating system in the house,
cottages, summer houses and caravans.
The communication to the device is performed by SMS text from
up to 6 mobile phones, one of which is the master number. At the
same time up to 6 people can control and surpervise the system.
-
Temperature
control
- Free of charge burglar alarm
- Remote readout of room temperatur
- Remote surveillance of water pipes
Start-up of HandyHeat GSM
A SIM-card is not included in the set so it should be bought separa-
tely and with the option to top-up its account.
Unlock of SIM-card:
SIM card should be unlocked,i.e. one should just delete the PIN-
code. The SIM-card should be put in the moble phone and in the
menu the PIN-code should be deleted. Afterwards the SIM-card is
put back to the HandyHeat GSM.
Change / RESET of masternumber
When a new SIM-card is used or the numbers on the SIM-card are
doubtful, the SIM-card itself can be reset. Leave the SIM-card in
the holder, remove the battery and switch off the current. Press the
RESET button in the upper right corner for 3 seconds. Afterwards
SMS with the text OUTPUT=00 is sent from the master number.
From now on the master number has the place NUM 1 in the me-
mory. Nobody else has access to the device before Service num-
bers are typed in. The service numbers get the places from NUM 2
til NUM 5.
Start-up:
When the device is activated the text with an actual status is sent
to all the numbers from the list in the SIM-card (first 6 numbers
in the memory of the SIM-card ) and the alarm is activated.
By the command ”LANGAUGE=1” the language number 1
is chosen, e.g. Danish.
By the command ”LANGAUGE=2” the language number 2
is chosen, e.g. English.
By the command ”LANGAUGE=3” the language number 3
is chosen, e.g. Spanish.
By the command ”LANGAUGE=4“ the language number 4
is chosen, e.g. Turkish.
By the command ”LANGAUGE=5” the language number 5
is chosen, e.g. Swedish.
By the command ”LANGAUGE=6” the language number 6
is chosen, e.g. Finnish.
The device reports with the text ” Language number=x” where
x is a number of the chosen language.
NB: Use only CAPITAL LETTERS in the text of SMS.
Alarm:
When alarm is activated the actual status of entrances is saved.
If the entrace data is changed an alarm SMS is sent with all the
changes. At the same time alarm is deactivated and the coming
changes cannot be registered. This SMS is sent to all numbers in
the list. By the start-up the alarm is activated.
GSM
Instruction manual
DANSK VARMEKABEL A/S
DANSK VARMEKABEL A/S
Language settings
SMS
command
Function
SMS
report
Outcome
position
Relay
position
1
TEMP
Read out the temperature
room
temp= xx.xC
2
HEAT ON
Heating is on.
Temperature is acoording
to the thermostat´s settings.
? HEAT ON
No signal on
Pilot wire exit
Relay 1
deactivated /
Relay 2 deactiv.
3
HEAT OFF
Heating is off.
? HEAT OFF
Positive
half of periods on
Pilot wire exit
Relay 1
deactiv. / Relay
2 activated
4 NIGHT
Temperature is sinking for
3,5 degrees.
? NIGHT
Positive/negative
periods on Pilot
wire exit
Relay 1 activat.
/ Relay 2
activated
5
FROST
Sinking of the temperature
for 7 degrees.
? FROST
Negative
half of periods on
Pilot wire exit
Relay 1 activat.
/ Relay 2
deactivated
6
ALARM ON
Air sensor is activated
?
ALARM
ON
The text message is
sent with activating
an entrance
7 ALARM
OFF
Air sensor is deactivated.
?
ALARM
OFF
The text message is
sent with activating
an entrance
By activating of
entrance (e.g. 2) and
alarm is connected
Alarm alarm=in2
changed !!
ALARM
OFF !!
Message to the device
Answer from the device
Explanation
STATUS
status=HEAT ON /
ALARM ON
/out3 off/out4
off/in1 off/in2 off/in3 off/in4
off/main on (11.1V)
/Signal=24
This is the message, that informs about the actual status
of the system for the moment it is sent. It is usually used
as a report for the receiving messages. It is send auto-
matically to all the numbers from the list. (11.1V) means
that there is a net service. If the battery is in use it should
be minimum7.0V otherwise the system will stop working
Signal=24 means that there is a cover for 24 at the mo-
ment by the scale from 0 til 30. The signal under 10 is
not so good.
SETNUM=2+4512345678
Encoding of the service 45 12345678 for
plce 2 in the memory list. “+”is obligatary before the
landline code. Place 1 is taken by the master number.
DELNUM=2
Example for deleting of the service number 2
LISTNUM
Svar 1: NUM 2=+4512345678
Svar 2: NUM 3=00
Svar 3: NUM 4=00
Svar 4: NUM 5=00
Svar 5: NUM 6=EMPTY
5 text messages are sent to the master number informing
what service number are in the memory list of the SIM-
card. The service number 2 is with the Danish landline
code +45 and telephone number 12345678.The numbers
from 2 til 4 are deleted and number 5 is empty.
LANGAUGE=1
Language
number=1
Language settings. 1 Danish
LANGAUGE=2
Language
number=2
Language settings. 2 English
no main! running on battery
(max 1 hour)(08.8V)
If the network disappears the text message is sent to all
the numbers from the list. To save the energy all relays
are deactivated. There is only 1 hour work capacity on
the internal battery. SMS is sent when network is back.