Status Indication
Depending on the scooter model, the status indicator may be a single lamp (or LED)
or a TruCharge battery gauge and diagnostics display. Both types indicate the status
of the controller. See section 10 for more details of TruCharge battery gauge.
Please note that a number of supposedly faulty controllers returned to PGDT are
subsequently found to operate correctly. This indicates that many faults are due to
problems on the scooter rather than within the controller.
8.1
Status Indicator Steady
This indicates that all is well.
8.2
Status Indicator Flashes Slowly
The controller is functioning correctly, but you should charge the batteries as soon as
possible.
8.3
Status Indicator Blinks Off Every 5 Seconds
The controller has detected that the batteries are being charged.
8.4
Status Indicator Flashes Rapidly (even with throttle
released)
The controller safety circuits have operated and the controller has been prevented
from moving the scooter.
This indicates that there is a fault. Please follow this procedure:
• Switch off the scooter.
• Make sure that all connectors on the scooter are mated securely.
• Check the condition of the battery.
• If you can’t find the problem, try using the self-help guide in section 8.5.
• Switch the scooter on again and try to drive. If the safety circuits operate
again, switch off and do not try to use the scooter. Contact your service agent.
8.5
Self-Help Guide
If a fault occurs and you have a scooter model fitted with a TruCharge display, you
can find out what has happened by counting the number of bars that are flashing
on the battery gauge.
The following diagrams give an overview of the fault types and a list of self-help
actions. Try to use this list before you contact your service agent. Go to the number in
the list which matches the number of flashing bars and follow the instructions.
8.6
Diagnostic Flash Code Feature
The Diagnostic Flash Code Feature is a factory programmed feature that allows a
single status lamp or LED to display the TruCharge fault code. This is done by pulsing
the lamp on for a number of times equivalent to the number of TruCharge bars that
would be flashing for a given fault.
Summary of Contents for Raptor
Page 1: ...Servicemanual Servicemanual Handicare Produksjon AS Serviceboks 2626 Lillehammer Norway...
Page 24: ...EGIS SERIES SCOOTER CONTROLLER OPERATION INSTALLATION SK75326 6 PG DRIVES TECHNOLOGY...
Page 32: ...PG DRIVES TECHNOLOGY 1 EGIS OPERATION SK75326 6 CHAPTER 1 OPERATION...
Page 33: ...EGIS SK75326 6 PG DRIVES TECHNOLOGY 2...
Page 49: ...EGIS SK75326 6 PG DRIVES TECHNOLOGY 18...
Page 50: ...PG DRIVES TECHNOLOGY 19 EGIS INSTALLATION SK75326 6 CHAPTER 2 INSTALLATION...
Page 51: ...EGIS SK75326 6 PG DRIVES TECHNOLOGY 20...
Page 72: ...PG DRIVES TECHNOLOGY 41 EGIS TILLER MODULE SK75326 6 CHAPTER 3 TILLER MODULE...
Page 73: ...EGIS SK75326 6 PG DRIVES TECHNOLOGY 42...
Page 86: ...PG DRIVES TECHNOLOGY 55 EGIS WARNING SUMMARY SK75326 6 CHAPTER 4 WARNING SUMMARY...
Page 87: ...EGIS SK75326 6 PG DRIVES TECHNOLOGY 56...
Page 94: ...PG DRIVES TECHNOLOGY 63 EGIS SPECIFICATIONS SK75326 6 CHAPTER 5 SPECIFICATIONS...
Page 95: ...EGIS SK75326 6 PG DRIVES TECHNOLOGY 64...
Page 97: ...EGIS SK75326 6 PG DRIVES TECHNOLOGY 66...
Page 105: ...SP1A SK73762 6 PG DRIVES TECHNOLOGY VIII...
Page 106: ...PG DRIVES TECHNOLOGY 1 SP1A PROGRAMMING SK73762 6 CHAPTER 1 PROGRAMMING...
Page 107: ...SP1A SK73762 6 PG DRIVES TECHNOLOGY 2...
Page 118: ...PG DRIVES TECHNOLOGY 13 SP1A DIAGNOSTICS SK73762 6 CHAPTER 2 DIAGNOSTICS...
Page 119: ...SP1A SK73762 6 PG DRIVES TECHNOLOGY 14...
Page 125: ...SP1A SK73762 6 PG DRIVES TECHNOLOGY 20...
Page 126: ...PG DRIVES TECHNOLOGY 21 SP1A SOLO DIAGNOSTICS SK73762 6 CHAPTER 3 SOLO DIAGNOSTICS...
Page 127: ...SP1A SK73762 6 PG DRIVES TECHNOLOGY 22...
Page 136: ...PG DRIVES TECHNOLOGY 31 SP1A EGIS DIAGNOSTICS SK73762 6 CHAPTER 4 EGIS DIAGNOSTICS...
Page 137: ...SP1A SK73762 6 PG DRIVES TECHNOLOGY 32...
Page 146: ...PG DRIVES TECHNOLOGY 41 SP1A S DRIVE DIAGNOSTICS SK73762 6 CHAPTER 5 S DRIVE DIAGNOSTICS...
Page 147: ...SP1A SK73762 6 PG DRIVES TECHNOLOGY 42...
Page 157: ...SP1A SK73762 6 PG DRIVES TECHNOLOGY 52...
Page 158: ...PG DRIVES TECHNOLOGY 53 SP1A WARNING SUMMARY SK73762 6 CHAPTER 6 WARNING SUMMARY...