02/10/2015
www.HandiQuilter.com
HQ Fusion User Manual | 31
Motor Speed Sensor Test
The Speed test helps you determine whether
or not there is a problem with the HQ Fusion speed
sensor. Before performing this test, remove the
bobbin case and the top thread.
Press the Start button and the machine needle
will begin moving at 1200 stitches per minute. The
white box will show a number that should stabilize
at 100 if the sensor is functioning properly. Pressing
Start again will stop the machine.
Press
X
to close this window or
Back
to return to
the Diagnostics Menu.
Speed
35%
Needle Position
Manual
Regulated
80
Presets
35%
50%
70%
REC
Diagnostics
X
Diagnostics
Speed Sensor Test
Passing Test:
The value stabilizes at 100.
Remove bobbin case and top thread.
Clear all objects from the needle
area. Press the start button
0
Calibrate Tension Test
You should only calibrate the tension under the
direction of Handi Quilter technical support.
While calibrating the tension, you will be asked to
do the following:
1.
Remove the tension knob.
2.
Gently press the spring against the tension discs
while not compressing the spring.
3.
While holding the spring in place, press Reset.
4.
When calibration is complete, replace the
tension knob.
Speed
35%
Needle Position
Manual
Regulated
80
Presets
35%
50%
70%
REC
Tension Calibration
X
Diagnostics
Reset
Calibration should only be done under the
guidance of a Handi Quilter Technician.
Carefully remove tension knob.
Gently press spring against tension
discs but do not compress the spring.
While holding spring in place,
press the Reset button.
Replace the tension knobs.
256
Alarms
The HQ fusion has two useful alarms: thread-break alarm and overspeed alarm. Touch the Alarm button
and then select either the thread-break alarm or the overspeed alarm enable or disable the alarm.
Thread-Break Alarm
•
Press the alarm button to enable. When enabled the button turns light
yellow. An alarm will sound if the top thread breaks.
Speed
35%
Needle
Position
Manual
Regulated
Overspeed Alarm
The overspeed alarm notifies you of an overspeed condition. This occurs if you are moving the machine
too fast for the stitch regulation to effectively maintain even stitches while quilting. More stitches per
inch means that you will need to move the machine slower to avoid an overspeed condition. Fewer
stitches per inch means you can more the machine faster before encountering an overspeed condition.