Cordless System Manual
Intermessage Delay (x5mS)
Output Delays Selection
A two-digit number and Save are required after scanning this programming
bar code. Refer to the Programming Chart (inside back cover).
Intercharacter Delay (x5mS)
This selection provides control of the time delays between data output by the
Cordless System to the host terminal. The actual delay is 5 milliseconds
multiplied by the programmed value (00 – 99).
Default = 00.
Example: You need a 45 millisecond delay. Scan the
Intercharacter Delay bar
code. Scan “0,” “9,” and Save on the Programming Chart (09 x 5ms = 45ms).
Intercharacter Delay is the time delay between data characters output by the
Cordless System to the host terminal.
Interfunction Delay is the time delay between function (key) codes output by
the Cordless System to the host terminal.
Intermessage Delay is the time delay between data messages or records
output by the Cordless System to the host terminal.
Interfunction Delay (x5mS)