background image

Item #1003 111 651 

Model #HD39377

Use and Care Guide 

LOW VOLTAGE FLOOD LIGHT

Part

Description

Quantity

A

Lens cover

1

B

50W Halogen T3 Bi-Pin Bulb

1

C

Body

1

D

Adjustment screw

1

E

Connector

1

F

Spike

1

PACKAGE CONTENTS

Assembly and Installation

1

 

Attaching and installing the light

2

 

Connecting the wires

WARNING:

 

Never push the fixture into the ground by the lamp body (C) or use a 

hammer to insert the spike (F) into the ground.

WARNING: The wire connector (E) contacts have sharp edges for piercing the 
main low voltage cable. To avoid injury, do not touch the metal contacts.

CAUTION: The wire from the low voltage power unit shall be 12-16 AWG type 
underground low Energy Circuit Cable or SPT2W.

CAUTION: Safe for outdoor operation

WARNING: To reduce the risk of FIRE OR INJURY TO PERSONS:

WARNING: Turn off/unplug and allow to cool before replacing lamp.

WARNING: Lamp gets HOT quickly! Contact only switch/plug when turning on. 
Do not touch hot lens, guard or enclosure.

WARNING: Keep the lamp away from materials that may burn. 

WARNING: Do not touch the lamp at any time. Use a soft cloth. Oil from skin may 

damage the lamp.

WARNING: Do not operate the luminaire fitting with a missing or damaged lens 
or bulb protector. 

IMPORTANT:  
•  Protect the wiring by routing it in close proximity to the light fitting, or next to a  
  building structure such as a house or deck. 
•  The landscape wire and connector can also be hidden under stone or buried  
  under grass at a maximum depth of 6” (15.24 cm). 
•  Do not submerge fixture in water.

 

Carefully remove the fixture from its protective packaging.

 

Remove the lens cover (A) by turning it counterclockwise.

 

Do not remove the lens from the lens cover.

 

Insert the bulb (B) into the bulb socket. Use a soft cloth, as oil from 
skin may damage the lamp bulb.

 

Replace the lens cover (A) on the body (C) by turning it clockwise.

 

Adjust the fixture’s angle by loosening the adjustment screw (D) and 
retightening it.

 

Ensure the lens points up  
and never towards the ground.

WARNING: Risk of Electric Shock. Install all luminaires 10 ft. (3.05 m) or more 
from a pool, spa or fountain.

WARNING: Install in accordance with all local codes and ordinances. 

 

Place the wire connector (E) on opposite sides of the low 
voltage cable (not included) where the fixture will be located.

 

Align and fit the main low voltage cable vertically to the slot of 
the wire connector (E) as shown.

 

Press the wire connector (E) together until fully seated and 
locked around the cable. Pre-set prongs will pierce the cable 
insulation and establish contact. Turn on the power unit. If the 
light fixture does not turn on, repeat the previous steps.

 

Once the clip-on connector (E) is in place, it is recommended 
to wrap it with electrical tape for additional protection. 

 

CAUTION BE CAREFUL! THE WIRE STABS ARE VERY SHARP!

 

After all fixtures are installed, turn on the transformer.

E

Only for use with low voltage power units with a maximum output rating of 15V, 

300W per secondary.  
FOR LANDSCAPE LIGHTING SYSTEMS ONLY. OUTDOOR USE ONLY. THE DEVICE IS 

ACCEPTED AS A COMPONENT OF A LANDSCAPE LIGHTING SYSTEM WHERE THE 

SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR LOCAL 

INSPECTION AUTHORITIES HAVING JURISDICTION.
ETL LISTED UNDER MODEL # U000-4275

Please read and save these instructions

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS 

IMPORTANT SAFETY INSTRUCTIONS 

Lighted lamp is HOT!

A

B

C

D

F

E

A

B

C

F

D

Summary of Contents for HD39377

Page 1: ...A by turning it counterclockwise Do not remove the lens from the lens cover Insert the bulb B into the bulb socket Use a soft cloth as oil from skin may damage the lamp bulb Replace the lens cover A on the body C by turning it clockwise Adjust the fixture s angle by loosening the adjustment screw D and retightening it Ensure the lens points up and never towards the ground WARNING Risk of Electric ...

Page 2: ... material or workmanship This warranty shall not apply to the finish on any portion of the product such as surface and or weathering as this is considered normal wear and tear The manufacturer does not warrant and specially disclaims any warranty whether express or implied of fitness for a particular purpose other than the warranty contained herein The manufacturer specifically disclaims any liabi...

Page 3: ...actos tienen bordes afilados para perforar el cable principal de baja tensión Para evitar lesiones no toque los contactos metálicos ADVERTENCIA Riesgo de choque eléctrico Instale todas las luminarias 10 pies 3 05 m o más de un estanque manantial o fuente ADVERTENCIA Instale de acuerdo con todos los códigos y ordenanzas locales IMPORTANTE Proteger el cableado de enrutamiento en las proximidades de ...

Page 4: ... otra falla que no se refieran a material defectuoso o mano de obra Esta garantía no se aplicará a el acabado de cualquier parte del producto tal como la superficie y o intemperie ya que esto se considera desgaste normal El fabricante no garantiza y especialmente niega cualquier garantía ya sea expresa o implícita de aptitud para un propósito en particular que no sea la garantía contenida en el pr...

Reviews: