45
K2 M - Part 2/2
Troubleshooting
4 Troubleshooting
4.1
What to do in the event of a malfunction
WARNING
Improper troubleshooting
Severe injuries and damage to property
−
Troubleshooting may only be carried out by authorised, trained
personnel who are familiar with how to operate the machine
and are in strict observance of all safety instructions.
In the event of malfunctions that pose an immediate threat to persons, equipment
or operational safety:
1.
Stop the machine immediately pressing either the
[Emergency Stop]
or the
red
[Stop]
button.
2.
Disconnect the machine from the mains and ensure it can not be switched
on again.
3.
Have an authorised specialist determine the cause and repair the malfunc-
tion.
4.2
What to do after rectifying the fault
Check,
1.
if the malfunction and cause of the malfunction have been professionally
remedied.
2.
whether all safety equipment has been installed in accordance with regula-
tions and are technically and functionally in perfect condition.
3.
whether, there are no individuals located within the danger area of the
machine.
4.3
Faults, causes and repairs
The following examples highlight possible undesired conditions of the machine.
This list makes no claim to completeness.
This information is designed to help operators recognise faults when operating the
machine and to rectify them.
Fault on the machine - saw unit
Fault description
Cause
Remedy
The red
[Stop]
button will not
stop the machine immediately
Fault in the electrical system
1.
Disconnect the machine from the
mains power supply.
2.
Contact Felder-Group service
centre.
Safety limit switch without func-
tion
Fault in the electrical system
1.
Disconnect the machine from the
mains power supply.
Summary of Contents for K2 M