background image

 
 
 
 

SAFETY  

 

A fireguard conforming to BS 8423:2002 
should be used in the presence of children 
and old or infirm people. 
Please note, this appliance should be used 
with the fire door closed at all times except 
when re-fuelling or de-ashing. 
 

Do not use aerosol sprays or any other 
flammable materials near the appliance  
under fire. 
Do not fit an extractor fan in the same 
room as the appliance. 
Fire cement is caustic, hand and eye  
protection should always be worn,  
prolonged contact with the skin should be 
avoided. 
 
Arada  Ltd will not be responsible for any 
consequential or incidental loss or 
injury however caused.  
 

Before continuing any further, with the  
installation of this appliance please read the 
following guide to manual handling. 
 

 

Always obtain assistance when lifting the 
appliance 

 

When lifting always keep your back straight, 
bend your back not your legs 

 

Avoid twisting at the waist. It is better to  

    reposition your feet. 

 

Avoid upper body/top heavy bending. Do 
not lean forwards or sideways when         
handling the fire 

 

Always grip with the palms of your hands               
do not use your fingertips for support 

 

Always keep the stove as close to the body 
as possible as this will minimise the    

    cantiliver action. 

 

Use gloves to provide additional grip. 

 
 
 
 

THE PRINCIPLE OF THE STOVE 

 
Your Hamlet

 

stove

 

is built to the highest  

standard of craftsmanship using the best  
materials and the most modern equipment  
available. It is a highly efficient and sophisticated 
piece of machinery and when properly installed 
and operated it should provide a lifetime of  
heating satisfaction. 
 
Safety is the most important consideration when 
installing your fire. If not properly installed and 
operated a house fire may result. Installation 
must comply with the Building Regulations and 
conform to all safety standards. 

 
Hamlet

 produce a variety of appliances ranging 

from the traditional to the modern in style and 
appearance, all bristling with „High Tech‟        
features. 
 
The fire door is fitted with a special high  
temperature ceramic glass panel through which 
the fire can be viewed. 
 
The stove is lined with firebricks or heat         
reflective panels which ensure complete          
combustion and provide a good heat store to 
even out  fluctuations in burning. 
 
An internal throat plate produces turbulence to 
encourage secondary combustion and direct the 
flue gas around the whole upper firebox before 
allowing it to escape up the chimney. 
 

Hamlet

 stoves are also fitted with an „air wash‟ 

so called because it provides a curtain of high 
speed preheated air behind the glass to help 
keep it clean and provide secondary air/over 
draught. 
 
The provision of two inlets on all stoves gives a 
wide range of primary / secondary air, under 
draught/over draught combinations. The  
optimum setting will only be established by  
experience in firing the appliance, and will  
depend on the type of fuel, the position of the 
appliance in the house, and conditions of  
chimney etc.

 

INTRODUCTION

 

Hamlet Camborne Deluxe Stoves 

Summary of Contents for BK055

Page 1: ...PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE Operating Installation Manual BK055 Rev 06 November 2009 Part No AFS1297 RANGE OF STOVES Camborne Deluxe Camborne Deluxe Medium Pictured...

Page 2: ...please contact the Hamlet retailer in your area or call our technical support department on 0844 8475107 Copyright 2008 Arada Ltd This booklet has copyright and may not be copied in whole or part or...

Page 3: ...Chimney Sweeping 18 Door Glass 18 Outer Finish 18 Summer Storage Non Usage 19 Adjusting the Door Hinges 19 Disassemble The Airwash 20 Centre Fire Door Rope Replacement 20 Fire Door Rope Replacement 21...

Page 4: ...HETAS IF IN DOUBT CONTACT HETAS LIMITED TELEPHONE NUMBER 0845 634 5626 www hetas co uk THIS STOVE MUST NOT BE CONNECTED TO A SHARED FLUE SYSTEM TO ALL USERS PETROLEUM COKE SOME OF WHOSE BRAND NAMES AR...

Page 5: ...odern equipment available It is a highly efficient and sophisticated piece of machinery and when properly installed and operated it should provide a lifetime of heating satisfaction Safety is the most...

Page 6: ...Deluxe Compact Camborne Deluxe Small Camborne Deluxe Medium Camborne Deluxe Large 1 Fuel Retainer 2 2 2 2 2 Grate Bars 5 7 9 11 3 Throat plate 1 1 1 1 4 Flue Spigot 1 4 1 5 1 5 1 6 5 Hot Plate 1 4 1...

Page 7: ...Camborne Deluxe Compact Camborne Deluxe Small Camborne Deluxe Medium Camborne Deluxe Large 9 Rear Liners 1 2 2 2 10 Side Liners 2 2 2 2 11 Rear Grate bar support 1 1 1 1 12 Comb Assembly comprising of...

Page 8: ...t water add in boiler type 0 6 8 10 Max Oputput to Room kW 3 3 8 5 7 7 6 Max Oputput to Water kW 2 2 2 2 3 3 4 Height mm 505 530 552 552 Width mm 393 477 586 672 Depth mm 377 386 382 467 Height to Cen...

Page 9: ...ll be installed on a floor with adequate load bearing capacity If the existing construction does not meet this prerequisite suitable measures e g load distributing plate should be taken to achieve it...

Page 10: ...ware of this Failure to correct an over drawing flue will invalidate the warranty Please remember that chimney draught is dependent on four main factors Flue gas temperature Flue height Flue size Flue...

Page 11: ...ng details on the chimney flue lining hearth and fireplace installation Approved Docu ment J of the Building Regulations for England Wales is available from The Stationary Bookshops and can also be vi...

Page 12: ...shared flue system that serves any other heating appliance TYPICAL REAR FLUE OUTLET as per BS 8303 1 Maximum 150mm 6 Horizontal Flue Section Minimum 150mm 6 Diameter Flue Soot Door Fire Retardant Rop...

Page 13: ...r Plate 1 5mm Thick Minimum Non Combustible Register Plate Minimum 1 5mm Thick Steel TYPICAL TOP FLUE OUTLET as per BS 8303 1 Typical Metal Insulated Chimney System Installed To The Chimney Manufactur...

Page 14: ...and then lowering end marked L onto the low section of the comb see fig 3 The upper bar is fitted in a similar manner but with the end marked L inserted in the rear channel and the end marked H seate...

Page 15: ...ner panels See Fig 6 Fit the throat plate with the single bend and two cut outs to the front facing up The projecting lugs sit on top of the side liners The long centre tab on the back edge rests on t...

Page 16: ...2 mbar If Building Control Consent route is being sought please complete the check list on page 17 For a registered Competent Persons Scheme such as HETAS please complete the Certificate Of Complianc...

Page 17: ...Profession Capacity Telephone No Address Postcode Signed Date Registered member of e g CORGI OFTEC HETAS NACE NACS 7 Hearth Form of construction new or existing 8 Inspection and testing after completi...

Page 18: ...mportant that the flue ways flue pipe and chimney be cleaned prior to lighting the appliance after a prolonged shut down period DOOR GLASS The door glass should remain clear during normal burning Howe...

Page 19: ...or catch This is quite normal and due to the settling of the casting The fire door can be re aligned as follows When the appliance is cold open the fire door so that it is at right angles to the front...

Page 20: ...ng or replacement Refit using the reverse of this procedure Fig 11 Unscrew Control Knob Fig 12 Lifting Cover From Body Fig 13 Inner Slider Removal Hamlet Camborne Deluxe Stoves CENTRE FIRE DOOR ROPE R...

Page 21: ...seal to length and glue into position Allow 30 minutes before refitting the door to the appliance FIRE DOOR GLASS REPLACEMENT In the event of the door glass being broken it can easily be replaced Ple...

Page 22: ...amage and replace if necessary Clean the air slots within the door s casting and slider plate s Reassemble into the door and refit the control knob You will note that the slider can be locked to a sel...

Page 23: ...vered in this manual please contact your Hamlet dealer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits so they can complete the service reco...

Page 24: ...acturer For Further Details Advice On The Use Of Other Fuels For additional further advise on fuels please refer to HETAS Tel 0845 634 5625 or www hetas co uk or Solid Fuel Associa tion Tel 0845 601 4...

Page 25: ...be minimised by burning hard for a short period 15 to 20 minutes twice a day Please Note To avoid chimney problems your appliance should not be burnt at a reduced burn rate without a period of fast b...

Page 26: ...or household objects from falling embers The ash pan should be emptied at least twice a day or when the level of ash reaches the top of the ash pan On no account should the ash be allowed to build up...

Page 27: ...to the Right as in Fig 20 AIR WASH SYSTEM The air wash has an internal sliding plate with slots housed in a cover plate and is located above the fire door Sliding the control knob to the right as far...

Page 28: ...fe This operation should be carried out with the door doors closed to prevent dust escaping into the room Move up and down vigorously the riddling lever ash will fall into the ash pan beneath the grat...

Page 29: ...t be taken when opening and closing the fire door as any surrounding areas of the stove will be very hot WARNING Never attempt to open the fire door whilst the appliance is in use WITHOUT the use of t...

Page 30: ...AOCXSL AOCSL AOCML AOCLL N A AOCSH AOCMH AOCLH ECB5 WBTRAY ECB7 WBTRAY ECB9 WBTRAY ECB11 WBTRAY 30 Aerosol Touch Up Paint Add On High Canopy Add On Low Canopy Add In Slab Boiler Wood Burning Upgrade K...

Page 31: ...Large 1 Fuel Retainers AFS1190 AFS1192 AFS1191 AFS1240 2 Throat Plate AFS1018 AFS1019 AFS1020 AFS1241 3 Grate Bar Set AFS001 AFS001 AFS001 AFS002 4 Hot Plate AFS009B AFS009 AFS009 AFS012 5 Flue Spigo...

Page 32: ...set AFS1279 AFS1279 AFS1279 AFS1279 14 Airwash Kit AFS1280 AFS1280 AFS1280 AFS1280 15 Fire Door Rope Kit with Rope glue AFS1021 AFS1021 AFS1021 AFS1021 16 Left Hand Fire Door Complete N A See Note1 AF...

Page 33: ...Small Cam borne Deluxe Medium Cam borne Deluxe Large 20 Comb and Extension Bar AFS1274 AFS1276 AFS1291 AFS1301 21 Grate bar Support AFS1275 AFS1277 AFS1170 AFS1246 22 Stove Mitten AFS1285 AFS1285 AFS...

Page 34: ...checked annually by a qualified heating engineer with documentation to be retained and produced in the event of a claim being made Claims are not valid where installation does not conform to appropria...

Page 35: ...ion must be retained and produced in the event of a warranty claim This guarantee specifically does not cover accidental damage misuse wear tear The use of non Hamlet replacement parts will invalidate...

Page 36: ...late Fuel Retainers Firebox Liners Throat Plate Air Wash Ash Pan Operating Tool Operating Installation Manual Stove Mitten Assembled By Checked by Date of Purchase Name and Address of Supplier Arada L...

Reviews: