background image

Document #101-0113

1

10/16/09

WARNING! Shock Hazard! DO NOT connect power or operate the

validator with the covers removed.

Introduction

Included with these instructions is a 28 pin EPROM for updating an XE validator. These instructions will detail
the disassembly of the validator, replacement of the EPROM and re-assembly. 

Before attempting the in-

stallation, please read through all the instructions carefully to see if you feel comfortable perform-
ing the steps required.

 If you are not comfortable working on electrical equipment where serious shock

hazards exist, you should contact a qualified technician to perform the installation for you. A list of Hamilton
Mfg. Corp. Factory Trained Service Representatives that are fully qualified to perform this update is included
in this instructional guide.

Tools Required

#2 phillips screwdriver

Small flat blade screwdriver

Small needle-nose pliers

Preliminary Testing

1.

Before beginning this update, confirm that the validator is functioning properly and is accepting the
old currency well. If not, you should have the validator serviced by a qualified technician.

2.

If the validator is working properly, be certain all electrical power to the changer or Autocashier has
been turned off before commencing disassembly and reassembly. Failure to do so may cause injury
or death. Then remove the validator and proceed with disassembly.

Disassembly

1.

Stand the validator upright on a solid work surface to perform the following steps.

2.

Remove the 6-32 x 1/8 screw from the top of the validator as shown in Figure 1.

XE VALIDATOR UPDATE

EPROM INSTALLATION INSTRUCTIONS

Summary of Contents for XE

Page 1: ...rainedServiceRepresentativesthatarefullyqualifiedtoperformthisupdateisincluded inthisinstructionalguide Tools Required 2phillipsscrewdriver Smallflatbladescrewdriver Smallneedle nosepliers Preliminary...

Page 2: ...tom left cornerfromtheframe 10 Remove the sensor cable at connector P1 and separate the circuit board from the validator EPROM Removal 1 Refer to Figure 3 and locate the EPROM at U1 on the circuit boa...

Page 3: ...board toward the validator frame and drop it down into place Be sure to tuck the sensor cable down between the transformer and the front cover so that no wires becomepinched 3 Install the cables at c...

Page 4: ...y Try insertingafewbillstobesurethevalidatorisworkingproperly 6 This completes the update process Your validator should now be capable of accepting both the old and new currency Troubleshooting Follow...

Page 5: ...ilton sobligationunderthe warranty is limited to replacing any defective part at its expense within one 1 year from the date of the purchase of the Validator Update If you elect not to use a Hamilton...

Page 6: ...Document 101 0113 6 10 16 09 WARNING Shock Hazard DO NOT connect power or operate the validator with the covers removed Figure 1...

Page 7: ...Document 101 0113 7 10 16 09 WARNING Shock Hazard DO NOT connect power or operate the validator with the covers removed Figure 2 SMALL CARDBOARD INSULATOR LARGE CARDBOARD INSULATOR SCREW 4 40x1 4...

Page 8: ...Document 101 0113 8 10 16 09 WARNING Shock Hazard DO NOT connect power or operate the validator with the covers removed Figure 3 Figure 4...

Page 9: ...Document 101 0113 9 10 16 09 WARNING Shock Hazard DO NOT connect power or operate the validator with the covers removed Figure 5 B A P3 P2 P1...

Reviews:

Related manuals for XE