background image

Air Purifier

840071100

Air Purifier Safety.......................... 2

Know Your Air Purifier .................. 5

How to Assemble and Use............ 6

How to Clean................................ 12

Troubleshooting Guide.............. 17

Customer Service ........................ 18

In USA: 1-800-851-8900

In Canada: 1-800-267-2826

Summary of Contents for 4160

Page 1: ...ir Purifier 840071100 Air Purifier Safety 2 Know Your Air Purifier 5 How to Assemble and Use 6 How to Clean 12 Troubleshooting Guide 17 Customer Service 18 In USA 1 800 851 8900 In Canada 1 800 267 2826 ...

Page 2: ... resulting in bodily injury or property damage 9 Do not operate this product in a garage or other area with oil or chemicals such as solvents or insecticides 10 Always unplug the power cord from the receptacle when the air purifier is not in use before cleaning replacing parts or before moving to another location 11 Do not insert foreign objects into the product for any reason Bodily injury or pro...

Page 3: ...e equal to or greater than the rating of the air purifier Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over Route the electrical or extension cord clear of furniture to prevent damage from pinching wWARNING Germicidal Light Radiation Hazard Never operate with damaged broken o...

Page 4: ...e filter which traps large dust particles and reduces odors 2 The white HEPA filter then removes particles as small as 0 3 microns from the air at 99 97 effectiveness 3 The clean air is then exposed to germicidal grade ultraviolet light to reduce the level of airborne bacteria molds and viruses The purified air is then released through the outlet grille on the top of the unit Each air purifier is ...

Page 5: ...3 Control Panel 4 AirSmart Sensor 5 UV Starter 6 UV Bulb Check Window not shown see page 8 for location 7 Filter Check Gauge 8 Air Sensor Cleaner 9 HEPA Filter 10 Carbon Pre Filter 11 Intake Grille Available on AirSmart models only Manual control models do not include these features ...

Page 6: ...vents or insecticides Do not place on or near heat sources such as stoves radiators or heaters or in direct sunlight To reduce electrical noise and interference do not place on or near or plug into the same outlet as TVs baby monitors or cordless phones DO Place the air purifier on a flat stable surface Place the air purifier near an electrical outlet where it is out of the way Make sure that the ...

Page 7: ...filter Locate the black carbon pre filter It will be folded inside a plastic bag Remove and discard the plastic bag Installing the Carbon Pre Filter Insert the two tabs on the bottom of the intake grille into the holes on the bottom ledge of the air purifier Pivot the intake grille into place and lightly press on the upper corners of the grille to snap it into place NOTE The air purifier has a saf...

Page 8: ...tips on the glass bulb will shorten the life of the bulb Carefully unpack the bulb and discard the packaging NOTE Make sure no loose packing material remains inside the air purifier Make sure the unit is unplugged Starting with one end of the bulb then the other gently insert the metal pins on the bulb into the white slotted socket one pin at a time NOTE Only one pin will fit in the socket at a ti...

Page 9: ...t of the opening Pivot the grille down toward the back of the air purifier Press lightly down on the back corners of the outlet grille to snap it into place NOTE The air purifier has a safety switch that prevents operation when the top outlet grille is not properly installed DO NOT attempt to override or disable this safety switch See the Germicidal Light Hazard Warning on page 3 Installing the UV...

Page 10: ...k never plug in the air purifier while your hands are wet Always unplug the air purifier before moving or servicing the unit NOTE The polarized plug will only fit in one direction DO NOT try to force the plug If you are unable to insert the plug into the outlet try reversing the plug If the plug still does not fit contact a qualified electrician to replace the obsolete outlet 4 Fan Speed Knob Turn...

Page 11: ... the sensor automati cally adjusts the fan speed for the most effective air purification The Display also has check marks that will appear to indicate that it is time to check the carbon pre filter or HEPA filter See Checking the Filters on page 13 Once the filters have been checked and if neces sary replaced press the recessed RESET button with the end of a pen toothpick or small nail This will r...

Page 12: ...ing the AirSmart Sensor On models equipped with the AirSmart sensor it is recommended to clean the sensor monthly 1 Remove the air sensor cleaner from the storage compartment behind the intake grille see item 8 page 5 2 The sensor is located on the side of the unit Open the sensor compartment as illustrated then place the air sensor cleaner into the sensor opening 3 Push the air sensor cleaner in ...

Page 13: ...ir purifier to allow you to check the condition of the filters It is stored in a compartment behind the front intake grille See item 7 on page 5 for location The HEPA filter should last approxi mately 12 months with continuous use less in areas with a high level of airborne particles such as dust or pollen The carbon pre filter will last approximately three months NOTE You must reinstall and snap ...

Page 14: ... filter and then use the filter check gauge to check the filter again If the colored cylinder still does not float up the gauge the HEPA filter must also be replaced Turn off and unplug air purifier Remove the used HEPA filter by gripping the sides and pulling outward as shown Discard the used filter It cannot be cleaned Obtain a replacement HEPA filter Insert the unwrapped HEPA filter hook fasten...

Page 15: ...on Beach To Remove the UV Bulb Turn off and unplug the air purifier Open and remove the outlet grille by pulling upon the handle on the upper back of the air purifier Gently rotate the bulb a quarter turn in either direction until it unlocks from the socket Pull the pins out the sides of the socket one end at a time To Install the New UV Bulb Refer to steps 3 through 6 on pages 8 and 9 to install ...

Page 16: ...and unplug air purifier Remove the intake grille and filters The starter is the small cylinder shaped part located behind the filter Turn the starter counterclockwise until it unlocks then pull it out To install the new starter insert the starter and turn clockwise Replace filters and intake grille Replacing the UV Starter 1 2 Starter ...

Page 17: ...owing section provides the solutions to many common problems and questions If your air purifier is not working correctly review these solutions first If your problem is still not solved after reviewing this guide call our toll free customer service number listed on the front cover of this manual for assistance The Air Purifier Will Not Turn On Are the intake grille and the outlet grille installed ...

Page 18: ...xclusion or limitation of incidental or consequential losses so the foregoing disclaimer may not apply to you If you have a claim under this warranty DO NOT RETURN THE APPLIANCE TO THE STORE Please call our CUSTOMER SERVICE NUMBER For faster service please have model series and type numbers ready for operator to assist you CUSTOMER SERVICE NUMBERS In the U S 1 800 851 8900 In Canada 1 800 267 2826...

Reviews: