3143 Production Drive
z
Fairfeild, Ohio 45014
513-874-3733
1
HA1000 and HA45
Standard Overhead Teller
Door Adjustment Instructions
Doc #08-319
Est. 4/7/11 Revision 1
Page 1: ...3143 Production DrivezFairfeild Ohio 45014z513 874 3733 1 HA1000 and HA45 Standard Overhead Teller Door Adjustment Instructions Doc 08 319 Est 4 7 11 Revision 1 ...
Page 2: ...ead screws from B6545 lower cover 2 Remove B6545 lower cover 3 Remove two H0673 phillips truss screws from B6546 upper cover 4 Remove B6546 cover to access two more H3580 screws Figure 1 H0673 Phillips Truss B6546 Upper Cover B6545 Lower Cover H3580 Hex Head Screw ...
Page 3: ...passes the H3581 spring plunger Note Do not over tighten the H3581 spring plunger This will cause the body of the H3581 spring plunger to wear against the door and fail prematurely 9 Adjust the position of the B6562 detent mounting block Loosen H3580 hex head screws holding B6562 detent mounting block and slide the block towards the right until it contacts the door in the fully closed position and...