26
Bore Alignment Using the L-111/L-102 and A-512/A-514
Two Point Buck-In Procedure
Step 1: Insert the Target in the
Near
Bore
Measure the nominal bore ID. Use the A-
514G Leg-Setting Gage to set the legs of
the A-514 Bore Adapter to the nominal
bore ID (see Page 10 for a detailed
procedure on how to set the legs). Insert
the target mounted in the self-centering
adapter into the
Near Bore
and carefully
mark the placement of the target in the
bore.
The target must be placed in the bore
at the exact location and exact orientation
each time it is inserted.
Note:
Ensure that the level on the back of the A-514A/B/C adapters is level. If the level is broken or not available,
ensure that the cable is at 6 o-clock when orienting the target.
Step 2: Insert the Laser in the L-111
Insert the laser into the L-111 Stand with
the level on the top, centered from left to
right.
Step 3: Position the L-111 Assembly
Position the L-111 assembly as close to
the near reference bore as possible and
power on the laser.