Non-interlocked housing label – notifies of a potential hazard when covers 

are removed 

 

 

 

UV Hazard warning  label  –  indicates hazardous levels of UV light are 

present. 

 

                                           Table 2:

 

Safety Label Meanings

 

2.5.  Safety Interlocks 

The TLS-EQ-9 is equipped with interlocks to prevent operation of the device when any of the following 

conditions are present: 

  An external interlock is open 

2.6.  External Interlocks 

External interlock pins are provided for the customer’s use.  Any suitable normally-open contact or solid-

state switch can operate the interlock circuit.   

The interlock circuit must be connected to enable the operation of the unit.  Should the interlock connection 

open during operation or standby, the source is immediately disabled, and all light output from the aperture 

ceases.  

2.7.  Correct disposal of the unit 

When the TLS-EQ-9 has finally been removed from service, observe all local environmental regulations for 

proper disposal. 

3. Preparation of System  

3.1.  Unpacking guide 

Start by inspecting all parts of the system for completeness and any damage incurred in shipping.  Remove 

the straps and corner protectors. Carefully cut the taped seams using a sharp utility knife – cut the two end 

seams first. Lift the top panel slightly and cut the center seam. Open the box and remove all padding 

materials from the top to expose the equipment 

Summary of Contents for Energetiq LDTLS TLS-EQ-9

Page 1: ...Model TLS EQ 9 Laser Driven Tunable Light Source LDTLS Operation Manual Revision 3 June 2022 Part Number DOC 9220...

Page 2: ...information including drawings schematics and specifications contained in this document are the property of Energetiq and shall not be reproduced in whole or in part without the written consent of En...

Page 3: ......

Page 4: ...1 TLS EQ 9 Main Housing 6 3 2 2 Internal Components 8 3 3 Optical Performance 9 3 4 Physical Specifications 9 3 5 Utility requirements 9 3 6 Remote Interface 9 3 7 External interlock connection 10 4...

Page 5: ...8 Warranty 21 9 Appendix 21 9 1 Dimensional Drawings 21 9 2 Environmental Requirements 22 9 3 I O Connector Pin Assignment 22 9 4 RS 485 Interface Pin Assignment 22 9 5 Remote Interface Schematic 23 9...

Page 6: ...losed space We suggest purging any beam transport space with dry nitrogen gas The TLS EQ 9 source must also be cabled correctly and connected to a power source with a protective earth ground prior to...

Page 7: ...es and skin Looking directly into the emitted light or allowing the light to fall on the skin will damage eyesight or cause skin burns WARNING If the equipment is used in a manner not specified by the...

Page 8: ...EQ 9 laser product is designated as Class 1 during all normal operation The parameters of the non accessible internal laser are given below in Table 1 Parameter Value Wavelength 974 nm Emission Type C...

Page 9: ...tion Labels and Safety Notifications Label Picture Description 1 Manufacturer s identification label on lamp house gives the manufacturer s name and address and the model serial number and date of man...

Page 10: ...ircuit must be connected to enable the operation of the unit Should the interlock connection open during operation or standby the source is immediately disabled and all light output from the aperture...

Page 11: ...immediately Do not attempt to substitute any parts There are no user serviceable parts inside the TLS EQ 9 Lamp House Save the pallet and all packing materials If it becomes necessary to ship the sys...

Page 12: ...for 12VDC power 4 RS 485 I O connector Provides access to control and status signals 5 Status indicator LEDs Light emitting diodes LEDs on the back of the TLS EQ 9 housing provide status information S...

Page 13: ...rature too high Laser power not reaching setpoint Laser temperature fault Internal power supply voltage low LAMP MODULE FAULT One of the following has occurred in the Lamp House module Control Cable n...

Page 14: ...s Dimensions H x W x D Lamp House 231 7 x 355 6 x 266 7 mm 9 125 x 14 0 x 10 5 in Weight 7 9 kg 17 5 lb 3 5 Utility requirements Lamp Controller Unit Electrical Electrical 12VDC 140W Cooling Fan 30 CF...

Page 15: ...any connections 4 1 1 Electrical Power The TLS EQ 77H requires 100 240 V 50 60 Hz input voltage Power consumption is 350 W maximum during normal operation Some OEM versions have higher current require...

Page 16: ...imit gas flow The lamp requires 1 8 OD tubing and the retroreflector requires 4mm OD tubing 2 Insert the Interlock Connector Bypass in the Remote Control 3 Connect the Remote Control to the Remote Con...

Page 17: ...20 150 seconds the igniter will be turned on automatically and the plasma will ignite The LAMP ON LED will be lit The duration of the warm up time 20 150 seconds will depend on the temperature and pre...

Page 18: ...25mm and 0 5mm is available To change the slits slide the installed slit upward to remove it from the monochromator as shown below in Figure 5 To install slide the slit into the same location The mon...

Page 19: ...20X B Gloves Nitrile rubber TechNiGlove replace X with digit for desired size A R LG 1 Laser safety glasses ThorLabs A R 7 1 1 3 Supplies and Tools Required Part Number Description Quantity 843 R USB...

Page 20: ...y to the Lamp power input connector o Connect the Monochromator Power Supply to the TLS EQ 9 Monochromator power connector o Connect the USB cable to the PC and TLS EQ 9 Monochromator control USB conn...

Page 21: ...16 2 3 Zero the power meter Power Meter functions are shown at left Turn Power Meter ON...

Page 22: ...length to 500nm 5 Turn the Remote Control OPERATE switch on Clear any faults if required by turning the OPERATE switch OFF ON The LASER ON LED will illuminate Wait for the LAMP ON LED to illuminate Wa...

Page 23: ...TLS EQ 9 At the chosen wavelength of 500nm the expected minimum output is 1 3mW If the output is 1 3mW or greater no adjustment is necessary Stop here If the output is below 1 3mW continue with the a...

Page 24: ...ne which direction results in an increase in the meter reading Continue turning in the appropriate direction until the meter reading is maximized 11 After turning the first adjustment screw move to th...

Page 25: ...ON position then to the OFF position The unit will not turn on if a fault condition exists If all the interlocks are OK and either the lamp or controller interlock faults will not clear please contac...

Page 26: ...rgetiq Technology Inc s warranty for the product is set forth in Section 5 of Energetiq Technology Inc s standard terms and conditions found at www energetiq com 9 Appendix 9 1 Dimensional Drawings TL...

Page 27: ...RNAL INTERLOCK apply 5V referenced to digital common to close interlock and allow operation Status Indicators Outputs LAMP ON 1 Pulled to digital common when ON LASER ON 2 Pulled to digital common whe...

Page 28: ...e power Laser power can be increased or decreased in increments of 0 5 of full scale The following describes the serial commands and their functions 0 1uF 100 Pins 1 2 3 4 Pins 6 7 8 9 Pin 5 499 Pins...

Page 29: ...e Power XX X Q Queries the value of the present laser power setpoint in of full scale Power XX X F Resets laser power setpoint to factory default value Power XX X B Saves present settings to flash mem...

Page 30: ...sion History Rev Effective Date Description of Change 1 09 Sep 2019 Initial release 2 19 Nov 2020 Updated labels and CE Declaration of Conformity 3 28 Jun 2022 Document style format labels and complia...

Page 31: ...26 Energetiq Technology Inc 205 Lowell St Wilmington MA 01887 Phone 1 781 939 0763 Fax 1 781 939 0769 Email info energetiq com Website www energetiq com DOC 9220 Rev 3 6 22...

Reviews: