Function Blocks PSx-3__-PN
18
ErrorDescription
Error Description as text
Type: STRING
Default value:
“”
Direction: OUTPUT
The priority corresponds to the order in the following table (highest priority has 16#x1xx).
ErrorID
ErrorDescription
16#x1xx
FB internal error
16#x2xx
Invalid PD input address
16#x4xx
Error while reading PD
16#xxx2
Under- or overvoltage motor supply
16#xxx4
Temperature exceeded
16#xxx5
Absolute measuring system error
16#xxx8
Incorrect target value
16#xxx9
Under- or overvoltage during run
16#xxx6
Block or overcurrent error
16#xxx7
Manual displacement
16#xxxA
Lower position limit exceeded
16#xxxB
Upper position limit exceeded
16#xxx3
Positioning run aborted
16#xxx1
Drag error
5.10
MC_ReadParameter (FB112)
With this FB values of parameters can be read by the drive. Each parameter can be read
except par. 13 (“device model as string”).
(View in Step 7 Classic V5.5)