WHAT’S IN THE BOX

 

Open the two boxes to show the MP5 sensor and the D20 display/controller: 

 

 

Item 

Description 

 

MP5 sensor 

 

D20 display/controller 

 

Note:

 product technical details be found in th

technical 

specifications

 at the end of this guide. 

 

Unpack the cardboard box protection liners and carefully remove its contents. The boxes should contain the 
following items: 

D20 display/controller 

MP5 sensor 

 

D20 display/controller 

 

Mounting tabs for wall mount 

 

Strain relief for 4-20mA cable 

 

This installation guide 

 

MP5 sensor for FC installation 

 

Flow cell with push-to-connect 
tubing fittings 

 

3/8" tubing (push-to-connect) 
adapters 

 

If in the unlikely event that something is missing, contact Halogen Systems before proceeding with the 
installation. 

W

HAT YOU’LL 

NEED 

You’ll need these tools and materials to install the 

display/controller and the sensor: 

 

#2 Phillips and flathead screwdrivers 

 

Screws that are appropriate for mounting the products on a wall or pipe 

 

Depending on how the products will be installed, you may need other tools not described in this guide. 

 

 

Before proceeding to the next step 

 

1.

 

Put away the empty boxes and packing material for safe keeping. 

2.

 

Determine the best, safest location for mounting the display/controller. 

3.

 

Gather all 

the tools you’ll need for the site installation.

 

4.

 

Don’t forget to use ou

checklist

 to check off tasks during installation. 

 

 

 

Summary of Contents for D20

Page 1: ...Halogen D20 Display Controller and MP5 Sensor Installation Guide...

Page 2: ...es a hazardous situation that could result in injury or death If on the instrument refer to the instruction manual for operation or safety information Risk of electric shock Indicates components or a...

Page 3: ...ON OF CONFORMITY Drinking Water Sensors are Tested and certified to NSF ANSI CAN 61 and 372 2020 Certificate date issued 7 23 2021 120VAC Displays Also Tested and Certified to Safety Requirements for...

Page 4: ...electrical connectors and fittings 6 Connect the 4 20mA wiring 7 Step 3 Set up Halogen sensor 8 Using the Halogen side stream sensor 8 To install the flow cell 9 Positioning the flow cell 9 Connect de...

Page 5: ...aph below shows a demonstration of the D20 display controller on the left and the MP5 sensor on the right mounted on a custom backplate to the wall The controller shows sensor measurements and other d...

Page 6: ...technique that results in successful results There are five steps to be performed in completing a typical D20 and MP5 installation 1 Planning Unbox and inspect the box content and gather tools necessa...

Page 7: ...mbient operating temperature and the actual power capacity after required derating if necessary 2 Communication For 4 20mA operation use 8 conductor 22 AWG cabling 3 Mount The controller should be ins...

Page 8: ...with push to connect tubing fittings 3 8 tubing push to connect adapters If in the unlikely event that something is missing contact Halogen Systems before proceeding with the installation WHAT YOU LL...

Page 9: ...low There are two ways to install mount the D20 at the site Mount to a wall or Mount to a pole TO MOUNT THE D20 TO A WALL With the cover closed carefully place the D20 on a flat work surface exposing...

Page 10: ...in relief must have an electrical cable that is within its specified diameter range Hole plugs should remain installed onto any unused connectors While the D20 controller doesn t require hard wiring o...

Page 11: ...T THE 4 20MA WIRING Connect the 4 20mA wiring with an 8 conductor 24AWG cabling 0 21 OD on the terminal block in the lower right corner of the motherboard using the wiring diagram Output Cabling 1 Chl...

Page 12: ...side stream sensor is a compact device that connects to a drinking water source using ID tubing It requires very little flow and is unaffected by changes in the flow rate however long tubing may dela...

Page 13: ...ill go 4 Hand tighten the collar thread downward until it stops Do not force POSITIONING THE FLOW CELL The flow cell must always be installed vertically where the outlet port points upward toward the...

Page 14: ...to select and enter values on the D20 As the D20 powers up the display shows a series of status messages like the following When the D20 power up is completed the sensor will start its start up seque...

Page 15: ...ller panel and choose 4 20 mA OPTIONS 2 Go to SELECT OUTPUT CHANNELS 3 Select OUT1 or any of the four channels To set the scaling limits between the PLC and the D20 1 In the 4 20mA Options menu select...

Page 16: ...W NEED is set to a numeric value on the controller relay activation will only occur when the flow reading exceeds 0 If No Flow is displayed on the controller the flow value will be displayed as a posi...

Page 17: ...te USING A FLOW SENSOR INTERLOCK The system will not energize the chemical pumps if sufficient flow is absent Enable Flow Sensor Interlock disabled by default on the controller The D20 is designed to...

Page 18: ...or to a pole Configure the electrical connectors and fittings Connect the 4 20mA cabling Step 3 Set up Halogen sensor Learn how the Halogen side stream sensor works Install the flow cell it must be v...

Page 19: ...D20 With the D20 cover opened remove the four screws from the high voltage shield 1 remove the shield exposing the underlying PCB 2 and replace any blown fuses 3 Use part number 5x20mm Slow Blow 3 5A...

Page 20: ...load Linear derating between 45 and 60 C 1 33 W C Storage conditions 20 to 70 C 4 to 158 F 0 to 95 relative humidity non condensing Altitude 2000 m 6562 ft maximum Pollution degree 4 Temperature Mini...

Page 21: ...at stable pH less than 8 5 0 5 pH unit from the pH at calibration Calibration stability 6 months typ Accuracy over change1 15 of the measured value 0 2 mg L1 Turbidity in sample without impact 3000 pp...

Page 22: ...pe 2 Threaded sensor mount adapter medium flange Use with metal pipe 5 up to 75 M12 4 W MF Wastewater D NF Drinking water WT 01 Wet tap with remover assembly and isolation chamber Use with corp stop v...

Page 23: ...air or attempted repair not authorized by the Halogen Systems Any product not used in accordance with the instructions furnished by the Halogen Systems Freight charges to return merchandise to the Hal...

Page 24: ...nsor interlock 13 Gems Sensors 13 Halogen side stream sensor 8 inspection step 11 installation of the display controller step 2 installation step 5 John Guest push to connect PTC fittings 8 limited wa...

Reviews: