background image

Models: 10137, 10138, 10139, 10140

Important: READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING. KEEP THESE INSTRUCTIONS  

FOR FUTURE REFERENCE. 

WARNING - Risk of fire or electric shock. To reduce the risk of electrical shock, fire, or injury to persons; read and follow 

all warnings and installation instructions before installing. All installation should be performed by a qualified electrician. 

Ensure power is off before installation or inspection. All wirings are performed in accordance with Electrical Code and local 

electrical code.

WARNING - Make certain power is switched OFF before starting installation or attempting any maintenance. Consult an 

electrician if not qualified to prevent electrical shock.

WARNING -Risk of Fire. Fixtures are rated for use in 120-277V,50-60Hz protected circuit and 90(rated supply wire)

FOR YOUR SAFETY - While performing installation described, gloves, safety glasses, or goggles should be worn.

Install this kit only in the luminaire that have the construction features and dimensions shown in the photographs and/or 

drawings.

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

Do not alter, relocate, or remove wiring, lamp holders, power supply, or any other electrical component. 

SUITABLE FOR WET LOCATIONS

Semi Cutoff Wall Pack Series

Installation Instructions

®

© 2018 Halco Lighting Technologies, LLC.  All rights reserved.  Halco and ProLED are registered trademarks of Halco Lighting Technologies. All sizes and specifications are subject to change. Print Edition 12-18-18

Halco Lighting Technologies | 2940 Pacific Drive | Norcross, GA 30071 | Toll Free 800.677.3334 | Phone 770.242.3612 | Fax 800.880.0822 | halcolighting.com | Atlanta | Cleveland | Houston | Los Angeles | Phoenix                     

Web-Guard Installation Parts List

Code Name

Quantity

A

Web-guard

1

B

Stainless steel 304 cross  

machine screws #8-32*5/8

4

C

304 stainless steel flat

4

D

304 stainless steel nut

4

E

Nylon flat pad cp4

4

Visor installation parts list

Code Name

Quantity

F

Visor

1

B

Stainless steel 304 cross 

machine screws #8-32*5/8

2

C

304 stainless steel flat

2

D

304 stainless steel nut

2

E

Nylon flat pad cp4

2

Beauty Plate Installation Parts List

Code Name

Quantity

G

Beauty plate

1

H

Stainless steel 304 cross

machine screws #8-32*1/4

4

Photocell installation parts list

Code Name

Quantity

I

Photocell

1

Motion sensor installation parts list

Code Name

Quantity

J

Motion sensor

1

High voltage driver installation parts list

Code Name

Quantity

K

High voltage drive  

347-480V

1

Installation steps:

STEP 1: Open the luminaire by loosening the two screws on the side and safely allowing the glass door to 

fall forward on the hinges at its base.
STEP 2: Prepare the back plate for mounting by drilling or knocking out the appropriate holes.
STEP 3: Remove the mounting plate from the back of the luminaire and position on installable surface.
STEP 4: Use the provided 4 screws to securely mount the plate on the desired surface.

STEP 5: If using electrical conduit, remove the screw cap from the desired conduit hole and replace with 

conduit. Route the branch circuit wires inside the luminaire. If using a junction box, bring the branch circuit 

wires through  the rear hole into the luminaire. 

STEP 6: Splice the branch circuit power leads to the luminaire power leads, black to black (hot), white to 

white (neutral).

STEP 7: Reattach the LED module and driver module to the back plate.

IMPORTANT
STEP 8: 
Apply caulk between rear of housing and mounting surface to prevent water entry.

A

B

C D E

F

G

H

I

J

K

Accessories

1. Open the box, remove the luminaire and remove the mounting panel.
2. Per the hole position of the installation panel, a hole is drilled on the installation 

surface,  and then the fastener is fixed on the installation surface through the  

installation panel.
3. Wiring before luminaire installation, the zero line is connected to the zero line.  

The ground line is grounded, and the live line is connected to the fire line
4. According to Figure 4, mount the luminaire directly to the mounting panel.

Open Frame

1. Install the wire guard based on below figure. Using the provided screws and  

nuts, secure the wire guard on each side of the luminaire

Wire Guard Installation Instructions

1.

2.

3.

5.

6.

4.