5 Features and Technical Data

HALscan scanheads offers the following interfaces, functions and features:

1. XY3-100 data interface and power connector
2. Beam entrance
3. M85x1 lens ring (can be removed)
4. M5 laser and head mounting screw holes

Model

HALscan 10.20 / 

HALscan 10X20

HALscan 16.20 / 

HALscan 16X20

HALscan 20.20 / 

HALscan 20X20

HALscan 30.20 / 

HALscan 30X20

Interface

two-channel XY3-100 (2D)

Model

HALscan 10N20

HALscan 16N20

HALscan 20N20

HALscan 30N20

Interface

Two-channel NX-02 (2D)

Digital resolution / 
accuracy

20 bits 

1)

Power supply 
requirements

+-15 V / 2 A

+-15 V / 3 A

Idle power 
consumption (no 
galvo movements)

< 7 W

< 10 W

Mirror size

10 mm

16 mm

20 mm

30 mm

Maximum Laser 
Power

50 W 

2) 

/ 90 W 

2) 3)

250 W @ 10600 nm 
(CO

2

)

500 W @ 1064 nm 

2)

1500 W @ 1064 nm 
CW 

2)

400 W @ 10600 
nm (CO

2

)

2 kW @ 1064 nm 

2)

500 W @ 10600 
nm (CO

2

)

4 kW @ 1064 nm 

2)

Screw thread for 
optics

M 79 x1 (M 85 x1 
with included lens 
ring)

M 85 x1

M 95 x1

Positioning speed

>7 m/sec

>5 m/sec

>4 m/sec

Marking speed

up to 3,5 m/sec

> 2,8 m/sec

> 2,2 m/sec

> 2 m/sec

Precision writing

650 cps 

4)

450 cps 

4)

320 

4)

260 

4)

Resolution

1 µrad

1,1 µrad

1,15 µrad

1,15 µrad

Total scanning 
angle

40 degrees

Scanner Lag 
(Tracking error)

0,18 msec

0,26 msec

0,32 msec

0,58 msec

1% step response 

0,36 msec

8

Summary of Contents for HALscan X20

Page 1: ...HALscan X20 N20 XY3 100 NX 02 Scanheads Users Manual 2020 2024 by HALaser Systems GmbH 1...

Page 2: ...ional Description 10 7 Electrical Connection 11 7 1 HALscan X20 XY3 100 Interface 11 7 2 HALscan N20 NX 02 Interface 12 8 Initial Operation 13 9 Mechanical Specifications HALscan 10 20 10N20 14 10 Mec...

Page 3: ...hout prior notice The given technical data base on specifications of the vendor of components or parts of the hardware Tolerances are to be expected Duplication of this manual in whole or in part or r...

Page 4: ...and HALscan 30X20 added 12 2022 Technical data clarified 11 2022 Description of HALscan 16X20 added 07 2022 Added missing backchannel description in pinout 07 2021 Naming scheme explanation added 06 2...

Page 5: ...tput it again It can t block or weaken the laser beam To prevent unwanted emission of the laser beam above a particular danger class the laser device must be fitted with a shutter or any other suitabl...

Page 6: ...he mirrors and galvos from dust and humidity Furthermore there should be no larger vibrations and it has to be ensured nobody and nothing can touch the mirrors or the galvos Corrosive and or wet and o...

Page 7: ...f this manual before using such a scanhead for the first time Furthermore this manual must be accessible to anyone who will be involved in developing installing or using a laser device featuring a HAL...

Page 8: ...racy 20 bits 1 Power supply requirements 15 V 2 A 15 V 3 A Idle power consumption no galvo movements 7 W 10 W Mirror size 10 mm 16 mm 20 mm 30 mm Maximum Laser Power 50 W 2 90 W 2 3 250 W 10600 nm CO2...

Page 9: ...ser does not hit the mounting points of the mirrors this would lead to damage of the scanhead together with a loss of any kind of warranty Depending on used pulses and frequency additional cooling of...

Page 10: ...files in order to get specific shapes of the output or to gain an additional level of accuracy for special applications The X20 HALscan scanheads support the following XY3 100 features and commands 2...

Page 11: ...V 10 15 V 11 GND 12 15 V 13 15 V 14 A 15 B 16 C 17 D 19 F 22 15 V 23 GND 24 GND 25 15 V The power supply needs to be a balanced 15 V 0 5 V tolerance ATTENTION When the scanhead is powered separately...

Page 12: ...12 15 V 13 15 V 14 DATA 17 BACK 22 15 V 23 GND 24 GND 25 15 V The power supply needs to be a balanced 15 V 0 5 V tolerance ATTENTION When the scanhead is powered separately power has to be fed into s...

Page 13: ...tion where it may start up in the middle of an already running data transmission This may lead to the first valid position command received is at an extreme and unexpected position In such a situation...

Page 14: ...hanical Specifications HALscan 10 20 10N20 Dimensions W x H x D 120 x 95 x 96 mm Size without lens ring W x H x D 120 x 122 x 96 mm Size with lens ring Drawing Beam Entrance Side Drawing Beam Exit Sid...

Page 15: ...hanical Specifications HALscan 16 20 16N20 Dimensions W x H x D 156 x 121 x 115 mm Size without lens ring and without optional water cooling connection Drawing Beam Entrance Side Drawing Beam Exit Sid...

Page 16: ...11Mechanical Specifications HALscan 20 20 20N20 Dimensions W x H x D 169 x 148 x 120 mm Size Drawing Beam Entrance Side Drawing Beam Exit Side 16...

Page 17: ...12Mechanical Specifications HALscan 30 20 30N20 Dimensions W x H x D 185 x 148 x 140 mm Size Drawing Beam Entrance Side Drawing Beam Exit Side 17...

Page 18: ...E1702S 12 E1803D 11f F F Theta 10 H Humidity 6 L Linear 10 M Maximum Laser Power 8 Mirror size 8 N N20 10 NX 02 7f 10 12 P Power supply 8 11f R Resolution 8 S Scale drift 9 Scanning angle 8 T Temperat...

Page 19: ...XY3 100 7f 11 XY3 100 features 10 Z Zero drift 9 19...

Reviews: