6. OPERATION (continued)

6-5  Checking “Auto Cal” information

6-6  Setting the load detection function

The HAKKO FN-1010 has the following functions for detecting the tip load.

Load repetition count function: 

 

The number of times a specified load has occurred is counted and stored 

in the tip.

Supplied energy calculation function:

  The amount of energy emitted during the period in which a load occurred 

is calculated.

6-7  Load repetition count alarm

If the specified number of load repetitions has been reached, the load repetition count alarm sounds a buzzer and 

vibrates the handpiece.

The count alarm value can be set according to the following procedure. The settable range is – – – – – – (OFF) and 

100 to 999,900.

1. 

With the normal screen shown, press 

the   button. The menu screen will 

appear. Select 

“Auto Cal Info”

 and 

press the   button again.

2. 

A list of the calibration results for 

the most recent 10 calibrations will be 

shown.

To see the details, use the   or   

button to select the desired calibration 

from the list, and then press the   

button.

Temp Set

Auto Cal

Auto Cal Info

Tip Info

Load Detection

Preset Temp

Offset Temp

400

OFF

00

1. 2018/03/23  17

:

15 P

2. 2018/03/23

 

17

:

13

 

F

3. 2018/03/23

 

17

:

13

 

F

4. 2018/03/23

 

17

:

12

 

F

5. 2018/03/22

 

11

:

11

 

P

Calibration Result

List

In the details screen, press the   or   

button to change the page. After checking 

the information, press the   button.

1. 

With the normal screen shown,  

press the   button. The menu 

screen will appear. Select 

“Load 

Detection”

 and press the   

button again.

2. 

The screen for setting the load 

detection function to ON or OFF will be 

shown. 

Use the   or   button to select 

“ON”

.

Temp Set

Auto Cal

Auto Cal Info

Tip Info

Load Detection

Preset Temp

Offset Temp

400

ºC

OFF

00

ºC

Load Detection

ON

OFF

1. 

With the normal screen shown,  

press the   button. The menu 

screen will appear. Select 

“Tip 

Info”

 and press the   button again.

2. 

The screen for checking and setting tip 

information will be shown.

Use the   or   button to select 

“Count Alm”

 and press the   button.

Temp Set

Auto Cal

Auto Cal Info

Tip Info

Load Detection

Preset Temp

Offset Temp

400

ºC

OFF

00

ºC

Shape

Load Count

PWR Time

Count Alm

Load Sensitivity

Tip Solder Type

SerialNo.

T36-D24

000000

00000000:00

OFF

3

LF

*************

Summary of Contents for FN-1010

Page 1: ...ct is a soldering iron with added functions for use with peripheral equipment such as thermometer Please read the manual carefully before operating the HAKKO FN 1010 Please keep this manual readily ac...

Page 2: ...tip 4 5 2 2 Removing tip 5 5 2 3 About tips 5 5 3 Station 5 6 OPERATION 6 6 1 Setting changing the temperature 6 6 2 Selecting a preset temperature 7 6 3 Setting changing the offset 7 6 3 1 Direct in...

Page 3: ...measured using the HAKKO FG 101 thermometer HAKKO FN 1101 soldering iron Power consumption 95W 21V Tip to ground resistance 2 Tip to ground potential 2mV Length of cord 1 2 m Length w o cord 180 mm wi...

Page 4: ...unter or workbench use only This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if t...

Page 5: ...item selection During normal operation Opens setting screen In setting screen Cancels input value and moves to previous screen During normal operation In normal screen switches between digital display...

Page 6: ...e and retighten the screws to secure it in place 2 Insert the cleaning wire A1561 into the tip cleaner FT401 81 and attach the tip cleaner to the iron holder FH210 81 Note It is possible to switch the...

Page 7: ...the Tip Info screen Refer to 6 7 Load repetition count alarm 5 3 Station CAUTION When connecting or disconnecting the soldering iron cord to from the receptacle always be sure to switch the power off...

Page 8: ...r changed by the following steps The settable temperature range is 50 450 120 840 F Input Time Date 2018 01 01 00 00 1 With the normal screen shown press the button The menu screen will appear Select...

Page 9: ...or button to select the desired Preset No After selecting press the button The selection will be stored in the internal memory and after the new temperature setting has been displayed heater control w...

Page 10: ...AUTO SEND button to send the measured data to the IR receptor of the FN 1010 Note For details on using the thermometer equipped with IR transfer function refer to the instruction manual for the thermo...

Page 11: ...ithin the set range it will be judged as passed If it is outside the set range temperature measurement and sending will be performed repeatedly for the previously set number of retries Note If the mea...

Page 12: ...om the list and then press the button Temp Set Auto Cal Auto Cal Info Tip Info Load Detection Preset Temp Offset Temp 400 OFF 00 1 2018 03 23 17 15 P 2 2018 03 23 17 13 F 3 2018 03 23 17 13 F 4 2018 0...

Page 13: ...instruction manuals available from the HAKKO Document Portal Please download the desired documents from there https doc hakko com 3 The count alarm value input screen will be shown Select ON and pres...

Page 14: ...with fresh solder 4 Turn the power OFF and remove the tip using the heat resistant pad Set the tip aside to cool 5 Remaining oxides such as the yellow discoloration on the tip shaft can be removed wi...

Page 15: ...nsor for breakage Measure the resistance of the heater and sensor while at room temperature and it should be 5 10 Solder does not wet the tip CHECK Is the tip temperature too high ACTION Set the appro...

Page 16: ...TE LTD TEL 6748 2277 FAX 6744 0033 http www hakko com sg E mail sales hakko com sg Please access to the following address for the other Sales affiliates http www hakko com HEAD OFFICE 4 5 Shiokusa 2 c...

Reviews: