background image

HAKKO FA-431 Fume extraction system

Power cord

Cap (inside main unit)

Remote control

2. SPECIFICATIONS

4. OPERATION

 HAKKO FA-431

Instruction Manual

Main filter (inside main unit)

Pre-filter

Instruction manual

1

10pcs.

1

FUME EXTRACTION

Thank you for purchasing the HAKKO FA-431 Fume Extraction system.

Please read this manual before operating the HAKKO FA-431.

Keep this manual readily accessible for reference.

2015.12

MA02798XZ151201

To prevent accidents or damage to the HAKKO FA-431, be sure to observe the followings:

 Use only genuine HAKKO replacement parts. 

 Do not operate the fume extraction without the filter; otherwise it may cause the unit to malfunction. 

 Hold the plug when inserting or removing the cord in/from the outlet.

 Do not allow the HAKKO FA-431 to become wet, or use it with wet hands.

 While using the HAKKO FA-431, don’t do anything which may cause bodily harm or physical damage.

 1. PACKING LIST AND PART NAMES

Please check to make sure that all items 

listed below are included in the package.

1

1

1

1

100 - 110V 120W   220 - 240V 110W

High    

   

Medium    

Low

4.7m³/min      3.7m³/min     2.8m³/min

97

% 

(

 

0.3μm)

ø55 mm

330(W) x 366(H) x 343(D) mm

7.2 kg

Power Consumption

Suction Capacity *1

Filtering Efficiency

Duct diameter

Dimensions

Weight (w/o cord)

OVERSEAS AFFILIATES

U.S.A.: AMERICAN HAKKO PRODUCTS, INC.

TEL: (661) 294-0090 FAX: (661) 294-0096

Toll Free (800)88-HAKKO 

                                                           4   2   5   5   6

http://www.hakkousa.com

HONG KONG: HAKKO DEVELOPMENT CO., LTD.

TEL: 2811-5588 FAX: 2590-0217

http://www.hakko.com.hk

E-mail:[email protected]

SINGAPORE: HAKKO PRODUCTS PTE., LTD.

TEL: 6748-2277 FAX: 6744-0033

http://www.hakko.com.sg

E-mail:[email protected]

   Please access to the following address for the other Sales affiliates. 

  http://www.hakko.com

HEAD OFFICE

4-5, Shiokusa 2-chome, Naniwa-ku, Osaka 556-0024 JAPAN

TEL:+81-6-6561-3225 FAX:+81-6-6561-8466

http://www.hakko.com  E-mail:[email protected]  

© 2016 HAKKO Corporation. All Rights Reserved.

*1 When using 2 ducts

* Specifications and design are subject to 

  change without notice.

This product includes such features as electrically conductive plastic parts and grounding of the unit 

as measures to protect the device to be soldered from the effects of static electricity. Be sure to observe 

the following instructions:

1. The plastic parts are not insulators, they are conductors. When making repairs or replacing

parts, take sufficient care not to expose live electrical parts or damage insulation materials.

2. Be sure to ground the unit during use.

3.WARNINGS, CAUTIONS, NOTES AND EXAMPLES

 

Do not absorb combustible, explosive or corrosive gas.

 

Store the fume extraction unit in a dry place.

 

Do not block the exhaust vent of the fume extraction unit.

 

Turn the power off when not in use, or left unattended.

 

Turn the power off when changing parts or storing the 

HAKKO FA-431.

 

This appliance can be used by children aged from 8 years 

and above and persons with reduced physical, sensory or 

mental capabilities or lack of experience and knowledge if they 

have been given supervision or instruction concerning use of 

the appliance in safe way and understand the hazards involved.

 

Children shall not play with the appliance.

 

Cleaning and user maintenance shall not be made by 

children without supervision.

WARNING

CAUTION

4. OPERATION

1. Open the upper cover and then remove the 

plastic bag from the main filter.

2. Put the main filter on the main unit. Set the 

filter with the arrow pointing down

(as shown in the illustration).

3. Fit the pre-filter on top of the main filter.

Be sure the pre-filter lies flat and completely 

covers the top of the main filter with no gaps.

 

Set the filter

4. Close the upper cover

HAKKO FA-431 

Fume extraction 

system

Cap

Main filter

Pre-filter

Remote 

control

Power cord

Pre-filter

Main filter

(facing the arrow 

 downward)

Duct set (Duct / Adapter / Rectangular nozzle or Round nozzle / Net)

● 

Duct set (not included)

or

Round nozzle

Net

Duct

(ø55 mm)

Adapter

Rectangular 

nozzle

1. Connect the power cord to the power receptacle on the right of the unit.

2. Plug the power cord into a ground wall socket.

3. Turn the power switch on. Power lamp will light up.

CAUTION

Close the cover before turning the power switch on.

Do not block the open port on purpose.

When the fan is running, do not open the upper cover.

・T

urn the power off when not in use. Failure to do so may result in shorter filter life.

The main filter on the HAKKO FA-431 should be changed once per year as a general rule. 

Continued use after the replacement period may result in malfunction.

CAUTION

Remove protective film before use.

CAUTION

Remote control operation does not switch off 

the power of the HAKKO FA-431. (Only the fan 

is stopped.) After work has been completed, 

set the power of the HAKKO FA-431 main unit 

to OFF.

※Fan of HAKKO FA-431 will operate in remote control.

(refer to the 

 Operation of the remote control”)

Power lamp 

(Green)

Flow selection 

switch

Low

High

Medium

Channel 

set mode

Remote control 

receiver

Exhaust vent

Inlet

※Adjust the flow suitable for working environment by using flow selection switch.

 

Attach the duct 

A. How to attach duct set

1. Refer to Figure 1(right), and attach the 

nozzle and adapter to the duct. 

Insert the nozzle and adapter until it stops, 

turn the nozzle clockwise. Make sure the 

nozzle and adapter are firmly attached.

     

Twist the nozzle tight enough to avoid 

coming off.

(Fig.1)

1 Insert the nozzle 

until it stops.

Turn the nozzle clockwise.

2

Be sure the duct is 

facing in the 

proper direction 

during assembly.

or

2. Fit the net on the nozzle. (Figure.2)

3. Insert the duct into the open port. 

If using one duct, ensure the cap is in place 

on the unused port.

When using two ducts, please store the cap 

inside the main unit next to the main filter as 

shown in Figure 3 (right).

   

(Fig.3)

(Fig.2)

Cap

● 

Fume extraction unit

Power switch

風扇組合
插頭

Reviews: