background image

 

 

STXL300C; STXL300CE 

 

INDIREKT ÉS ELEKTROMOS FŰTÉSŰ ÁLLÓ FORRÓVÍZTÁROLÓK: 

INDIRECT AND ELECTRICALLY HEATED FLOOR-STANDING HOT WATER TANKS: 

 
 

Felszerelési és használati útmutató 

Instructions for installation and use 

HU EN  

 
 

1221114100/02 

Summary of Contents for STXL300 Series

Page 1: ...STXL300CE INDIREKT S ELEKTROMOS F T S LL FORR V ZT ROL K INDIRECT AND ELECTRICALLY HEATED FLOOR STANDING HOT WATER TANKS Felszerel si s haszn lati tmutat Instructions for installation and use HU EN 12...

Page 2: ...12 7 ZEMBE HELYEZ S 13 8 F BB EGYS GEK KARBANTART SA S SZERVIZEL SE 14 9 M SZAKI ADATOK 17 DEAR CUSTOMER 19 1 WARNINGS 20 2 ACCESSORIES 24 3 OPERATION AND STRUCTURAL DESIGN 24 4 MOUNTING AND INSTALLA...

Page 3: ...in s ge s megb zhat s ga Szolg ltat saink f er ss gei a sz lesk r s biztos szerviz s p talkatr sz ell t s T rsas gunk sz m ra fontos szempont a k rnyezet meg v sa a k rnyezetterhel sek minimaliz l sa...

Page 4: ...ntart son k v l b rmilyen m veletet k pes tett szakembernek kell elv geznie Jav t s vagy karbantart s el tt a k sz l ket fesz lts gmentes teni kell A k sz l k zembe helyez s t s els beind t s t szakem...

Page 5: ...a h l zati nyom s ak r id legesen is meghaladja a 1 MPa rt ket a forr v zt rol el nyom scs kkent szelepet kell be p teni A biztons gi szelep s a k sz l k k z v zvezet ki szerelv nyt be p teni tilos A...

Page 6: ...ember t vol thatja el ennek figyelmen k v l hagy sa ram t shez vagy m s vesz lyhez vezethet A biztons gos zemel s rdek ben c lszer id nk nt kb vente szakemberrel ellen riztetni a k sz l ket s a kombin...

Page 7: ...az n ltal megv s rolt term k letciklusa ut n boml si tulajdons gaival a k rnyezetet els sorban a talajt s a talajvizet k ros thatja mivel olyan alkatr szeket is tartalmaz melyek miatt az elhaszn l do...

Page 8: ...l gy hossz id n kereszt l melegv z nyerhet a t rol b l A bels tart lyt k r lvev poliuret n h szigetel s megakad lyozza a v z gyors leh l s t gy hossz id n kereszt l melegv z nyerhet a t rol b l A t r...

Page 9: ...9 jelens g tmeneti a h l zat fokozott bl t s vel gyakoribb v zcser vel t bl t ssel cs kkenthet...

Page 10: ...k ll t s val lehets ges A k sz l ket gy kell telep teni hogy annak falt l val t vols ga min 50 mm legyen tov bb a z r fed l kiszerelhet s ge s a tart ly belsej nek tiszt that s ga rdek ben az elektro...

Page 11: ...a kifoly csonk f gg legesen lefel ker lj n s a lef vat gomb hozz f rhet legyen Ezt a cs vet nyitva kell hagyni a l gt r fel A leereszt cs vet fagymentes helyre k sz l kt l lefele kell elvezetni biztos...

Page 12: ...zak t kapcsol n kereszt l szabad a t rol hoz vezetni ami a III t lfesz lts g kateg ria k r lm nyei k z tt teljes lev laszt st biztos t Nyitott rintkez i k z tti t vols g legal bb 3 mm Sz ks ges h l za...

Page 13: ...zel val felt lt se ut n a k sz l k zembe helyezhet Az els felf t sn l szakemberrel ellen riztesse a helyes m k d st 7 1 A k sz l k zembe helyez s t s els beind t s t k pes tett szakembernek kell elv g...

Page 14: ...sa nincs e elz r dva s a szelep m k d se sor n a szabad l gt rbe val ki raml s biztos tott e A kifoly ny l snak lefel kell llnia A t rol leh lt llapot ban a biztons gi szelep lef vat gombj nak a ny l...

Page 15: ...l toz sa A forr v zt rol termoszt t le van plomb lva s semmilyen indokkal sem szabad rajta esetleges t szab lyoz sokat vagy jav t sokat v gezni a mi zem nkben elv gzetten k v l kiv ve a mutat forgat s...

Page 16: ...l sz tszerel se ut n az jb li sszeszerel st minden esetben j t m t ssel javasoljuk Az ism telt ellen rz s id pontj t a szerel hat rozza meg Ha az an d tm r je ak r egy helyen is 10 mm re cs kken az a...

Page 17: ...r l 65 C ra h 9 5 K szenl ti energiafelhaszn l s 65 C on kWh 24h 2 26 Be p tett biztons gi s szab lyz elemek h m rs klet szab lyoz korl toz V zcsatlakoz s k ls menetes G3 4 Cirkul ci csatlakoz s bels...

Page 18: ...18...

Page 19: ...nd reliability The key strength of our service is the provision of an extensive and secure service network and parts supply Our company also considers it vital to protect the environment and minimize...

Page 20: ...at may be carried out on the appliance by the user must be conducted by a qualified expert Before carrying out any repair or maintenance the appliance must always be disconnected from the power supply...

Page 21: ...connecting copper water supply piping to the network Putting the storage tank under greater pressure than 1 MPa is dangerous and forbidden If the network pressure exceeds 1 MPa even intermittently a p...

Page 22: ...larly qualified experts Only a qualified expert may remove the electric cover plate Failure to follow this instruction can result in an electric shock or other hazard In order to guarantee safe operat...

Page 23: ...note that at the end of the lifecycle of the product you have purchased its characteristics have the potential to harm the environment primarily the soil and groundwater since it contains components...

Page 24: ...apacity to dissolve metals it is recommended to use cold water for cooking and drinking and consume it after heating when hot water is needed The temperature of the water in contact with the container...

Page 25: ...the following solutions for mounting the appliance Horizontal levelled fl oor to ensure the absolute vertical position of the appliance Vertical adjustment can be achieved by appropriately adjusting t...

Page 26: ...on of the threaded tank pipes nor assume liability for damages caused by the same It is forbidden and dangerous to expose the tank to pressures higher then the allowed operating pressure 5 2 The valve...

Page 27: ...k for the purposes of maintenance works Figure 10 2 5 6 If the user may be exposed to hot water during the withdrawal of water we recommend to implement a hydraulic connection with hot water protectio...

Page 28: ...onnection drawing shown both on the electrical safety cover and in Figures 10 4 We recommend to use a residual circuit breaker within the electrical network of the facility 6 4 It is FORBIDDEN to oper...

Page 29: ...and regulator switches off When about 15 of the water is discharged the regulator should switch back on automatically If the heating fails to turn on contact a technician for STXL300CE type 8 MAINTEN...

Page 30: ...ing 8 3 Descaling Depending on the quality of water scale may deposit on the radiator and the tank whereby descaling should be performed every two years Descaling requires the emptying of the tank the...

Page 31: ...tected against corrosion by active anodes The service life of the active anodes is subject to the water quality and the operating conditions The condition of the anodes must be checked upon each desca...

Page 32: ...g power W 2000 Voltage V 230 Current input A 9 Heat up time from 15 C to 65 C h 9 5 Standby energy consumption at 65 C kWh 24h 2 26 Integrated safety and regulator elements temperature controller limi...

Page 33: ...3 10 MELL KLETEK ATTACHMENT 10 1 STXL300C E k ls m retek STXL300C E external dimensions G 3 4 Rp 1 G 3 4 Rp 1 Rp 3 4 O11 x 41 O11 x 41 115 215 615 1047 1147 1247 1347 1032 100 1490 20 40 729 660 O 9 0...

Page 34: ...g p szeti bek t s building technology connection P P 1 3 2 4 5 6 MV C HB HK HV 10 3 p letg p szeti bek t si bra t lnyom s ellen building technology connection against overpressure 38 C 10 C 1 8 5 7 MV...

Page 35: ...yoz szelep C Cirkul ci bemenet 4 Biztons gi lef vat szelep HB H cser l f t k zeg bel p s 5 Kombin lt biztons gi szelep HK H cser l f t k zeg kil p s 6 Csatlakoz s a csatornah l zatba FE F t s elmen 7...

Page 36: ...e HK Heat exchanger heating medium outlet 6 Connection to the sewage network FE Heating downstream 7 Thermostatic mixing valve 38 C FV Heating return 8 One way valve K Solid fuel boiler 9 Directly con...

Page 37: ...37...

Page 38: ...38...

Page 39: ...39...

Page 40: ...40 QR k d HAJDU Hajd s gi Ipari Zrt 4143 T gl s k lter let 0135 9 hrsz telefon 52 582 700 gyf lszolg lat 52 582 787 e mail hajdu hajdurt hu www hajdurt hu...