42
HPT 300 • HPT 300C
Warning:
You must connect air ducts to both the inlet and outlet, in order to ensure
appropriate IP protection, if you discover moist condensation on the ceiling above the
appliance.
Operation using an air duct results in the loss of some air-flow and heat pump capacity
in the system. If you do not connect air duct to the appliance, you must ensure within
the room that no moist or condensation may occur in the space above the appliance in
any case.
Figure 9.1.-3.
Leveg
ő
belépés
HAJDU 200 9.1. 3. ábra.
Leveg
ő
kilépés
Air inlet
Air outlet
The air inlet is not connected to air duct, but the air outlet is. A ≤ 10 m
Recommendation:
Use it in case of heat surplus or if it is used in a room with heat sur-
plus in winter.
HAJDU 200 9.1. 4. ábra.
Leveg
ő
kilépés
Leveg
ő
belépés
Figure 9.1.-4.
Air inlet
Air outlet
The air inlet is connected to an air duct, but the air outlet is not. A ≤10 m
Recommendation:
This connection method helps refresh the air within the room du-
ring summertime.