____________________________________________EN________________________________________11
b)
In order to ensure adequate operation of the appliance and to ease maintenance, the selected
location has to possess suitable safety distances as measured from the walls and the ceiling
(Figures 7.1.-1 and 7.1-2.)
c)
Feet fixing: Make sure that the flooring is flat enough, possessing adequate stability. With the
help of the „drill frame” (usage manual),
set the positions of the feet fixing, taking into
consideration deployment sizes indicated on figures 7.1.-1, and 7.1.-2. of the usage manual.
Mount the 3 feet fixing items attached to the appliance with screws of M8 size and metal hit
anchor drilled into the flooring as minimum (M8x75), while the feet fixing is positioned
according to figure 7.1.-3. Fix the setable feet of the appliance at a distance of min. 26 mm
(see figure 7.1.-4.) Push the appliance carefully into the direction of the feet fixing srewed
down in a way that the setable feet are hit up in the open mortice of the feet fixing (figure 7.1.-
5.).
If the appliance is operated without any feet fixing, it might turn upside down. In this case,
the manufacturer shall not be liable to any damages emerged.
3.4.
Before installation, installation space requirements
Figure 7.1.-1.
Figure 7.1.-2.
Figure 7.1.-3.
Air inlet
Display
Air outlet
Protective grid