CLI Command Reference
passthrough
Makito X User’s Guide, v2.0, Issue 01
313
PASSTHROUGH
E
XAMPLE
PASSTHROUGH
S
TATISTICS
When a remote client is connected, the state will show up as CONNECTED and the IP
address of the client will be displayed.
The statistics are divided in two sections: network and serial.
•
The network stats show what is going in terms of the TCP connection with the remote
controller, i.e., how many bytes were received from and sent to the remote controller.
This example shows how to use TCP port 8888 to listen for passthrough clients. The
camera has an RS232 COM port running at 9600 bps:
#passthrough set port=8888 baudrate=9600 standard=rs232
Passthrough configured successfully.
#passthrough get
Configuration:
TCP Port
: 8888
Standard
: RS-232
Baud Rate
: 9600
Flow Control
: None
Disconnect Timeout : None
If passthrough is not started, you will have to start it:
# passthrough get stats
Statistics:
State : DISABLED
# passthrough start
Passthrough started successfully.
# passthrough get stats
Statistics:
State
: LISTENING
Caller Address
: 0.0.0.0
Network:
Rx Bytes
: 0
Tx Bytes
: 0
Serial:
Rx Bytes
: 0
Tx Bytes
: 0