Sensor & Intelligent Control

Mounting Height

 

Max.4m/13.12ft Ceiling Mounted 
Detection Range

Max. Diameter 10m/32.8ft Ceiling Mounted

Function Setting

DIP Switch/Remote Control

Microwave Power

<0.3mW

Microwave Frequency

5.8GHz±75MHz

Motion Detection

0.5-1m/s

Operating Temperature

-20°C~+60°C

IP Rating

IP20

Warranty

5 years

Operating Current

<30mA

Stand-by power

<0.5W

Control Method

ON/OFF    0-10V DIMING

Detection Angle

150° Wall mounted   360° ceiling mounted 

Detection Angle

DIP switch : 50%/100%      Remote control : 25%/50%/75%/100%
Hold Time

DIP switch :10s/1min/5min/10min     Remote control : 5s/30s/1min/3min/5min10min/20min/30min

Daylight Threshold

DIP switch :10Lux/30Lux/50Lux/Disable     Remote control :2Lux/10Lux/30Lux/50Lux/80Lux/120Lux/Disable

Stand-by period

DIP switch :1min/ 30min/ 60min/+

     Remote control : 0s/10s/30s/1min/ 5min/10min/ 30min/ 60min/+

Stand-by dimming level

 

DIP switch :10% 20% 30% 50%      Remote control :10% 20% 30% 50% 

Connection Type

Quick Connector

Technical Data

Operating Voltage

DC:10.5-15V

On/Off Control

Detection Area

Daylight Sensor

Hold Time

Warranty

Stand-by period

Stand-by dimming level

Remote Control

DC input , Rod antenna

HB001VCR-1A     HB001VCR-2A

   Automatic On/off control with Daylight sensor.   DC input      Compact sized particularly suitable for Tri-proof light     5 year warranty.

HB001VCR-1A

HB001VCR-2A

Summary of Contents for HB001VCR-1A

Page 1: ...min 10min Remote control 5s 30s 1min 3min 5min10min 20min 30min Daylight Threshold DIP switch 10Lux 30Lux 50Lux Disable Remote control 2Lux 10Lux 30Lux 50Lux 80Lux 120Lux Disable Stand by period DIP s...

Page 2: ...1 2 2 3 3 4 3 4 4 5 6 5 6 0 2 5 0 5 1 0M S Ceiling Mounted Mounting Height Antenna module IR Receiver Daylight Sensor Hold Time Installation Hole Stand by dimming level Stand by Period Daylight Thres...

Page 3: ...motion regardless the ambient brightness The period of light keeping low output before it s completely switched off When it s preset as the light always keep at low output if no movement in the detect...

Page 4: ...nsor turns light ON when motion gets detected The sensor keeps light ON for holdtime period after motion leaves The sensor turns OFF light automatically after the holdtime 3 Corridor Function Bi level...

Page 5: ...y from the driver to avoid interference genera tion and lamp ashing 6 Wiring must be strictly in accordance with the wiring diagram to avoid short circuit Application Environment 1 Suitable for indoor...

Page 6: ...sswill make the whole screen blink gently Also known as sensitivity 100 means the highest sensitivity and longest distance Press it specific icon on the screen will blink and press the buttons to adju...

Page 7: ...rn on the light 2 SCENE button to start programming 3 START button 4 Choose functional button of detection area see icon blinking on the LCD screen display then use buttons to change 5 Same programmin...

Reviews: