Quick change-over system centroteX M
Faults
Order h49 7144.907-333
69
13.2 Fault table
Fault
Possible cause
Remedial action
Remedied by
Incorrect axial
strokes in the
quick change-over
system
Dirt in the compo-
nents in the power-
flow
Remove and clean the quick
change-over unit / quick change-
over adapter. If necessary, re-
move, dismantle and clean the
machine adapter
Skilled special-
ist
Defective drawtube
adapter
Consultation with the manufac-
turer
Manufacturer
The set-up dimen-
sion was not main-
tained
Check the set-up dimension and
correct if necessary
Skilled special-
ist
Incorrect drawtube
position
Check drawtube position and
compare against the quick
change-over system
It is no longer pos-
sible to install the
quick change-over
unit / quick
change-over
adapter
Defective axial
strokes in the quick
change-over sys-
tem
See fault »Incorrect axial strokes
in the quick change-over system«
It is difficult to take
down the quick
change-over unit /
quick change-over
adapter
Dirt on the quick-
release screws
Use force to release the quick
change-over unit / quick change-
over adapter and clean the quick-
release screws
Skilled special-
ist
Clamping force is
too weak
Axial actuating
force on drawtube
too weak
Check machine setting and cor-
rect if necessary
Skilled special-
ist
Clamping force is
too high
Axial actuating
force on drawtube
too high
Check machine setting and cor-
rect if necessary
Skilled special-
ist
Geometry devia-
tion on the work-
piece
Axial run-out error
on the quick
change-over sys-
tem
Check axial run-out on the quick
change-over system and correct if
necessary
Skilled special-
ist
Face run-out error
on the quick
change-over sys-
tem
Check face run-out on the quick
change-over system and, if neces-
sary, clean the locating surfaces
Indentations on
the clamping
surface
Dirt on the CEN-
TREX support
Remove and clean the quick
change-over unit / quick change-
over adapter and the CENTREX
support
Skilled special-
ist