INSTALLATION AND OPERATING INSTRUCTIONS 

 

A2203

 

SYSTEM POWERED, NON-PROGRAMMABLE

 

DIGITAL HEAT & COOL THERMOSTATS

 

I M P O R TA N T !

 

Please read all instructions carefully before beginning installation 

and save for future reference. Before removing any wiring from 

your existing thermostat, the wires must be labeled with their 

terminal designations. Ignore the color of the wires since they 

may not comply with any standard. 

 

 
Thank you for your confidence in our product. You should become fully 
acquainted with this thermostat before installing it for usage. Follow the 
installation procedures carefully, and one step at a time. This will save you time 
and minimize the chance of damaging either the thermostat or the systems that 
it controls. These instructions may contain information beyond that required for 
your particular installation. Please save these instructions for future reference.   
 

   

COMPATIBILITY  

 
•The multi-stage A2203 thermostat can be used with most 24 volt, 2 stage heat     
and/or 2 stage cool: gas, oil, or electric heating and air conditioning systems,   
single-stage heat pump, or single-stage heat pump with Aux heating 
systems.  .  
 
•These thermostats cannot be used to control gas

 

Millivolt heating systems, 

multi-stage heat pumps, or 120/240 volt (line voltage) heating or cooling 
systems. Ask your dealer for other thermostats to control those systems.   
 

FEATURES  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
• Digital, Non-Programmable                                                                                             
• System Powered Only   
• Set Temperature Range 45°F to   
    95°F 
• Clean, Attractive Design   
• Easy To Install   
• Gas / Electric Blower Fan Option 
 

   

INSTALLATION                                                             

 
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING 
INSTALLATION.  
 

C A U T I O N 

This thermostat is protected against normal static electric

 

discharges. However, in extremely dry weather you should touch

 

a grounded metal object before touching the thermostat to

 

minimize the risk of causing damage to the unit.

 

 
TOOLS REQUIRED:   

 #1 Phillips screwdriver (small - medium) 

 

 Drill with 3/16-in. (4.8mm) drill bit 

 

 Wire stripper/cutter    

 

              C A U T I O N :   

Turn off electricity to the appliance before 

installing or servicing the thermostat or any part 

of the system. Do not turn the electricity back on   

until the work is completed.   

  • Your thermostat is a precision instrument. Please handle it with care.       

 

  • Do not short (jumper) across the electric terminals on either the 

 

    furnace or air conditioner to test the system. This may damage the 

 

  thermostat and void your warranty. 

 

  • All wiring must conform to all applicable local codes and ordinances.   

• This thermostat should be limited to a maximum of 3 amps; higher 

 

    current may cause damage to the thermostat. 

 

 
THERMOSTAT  LOCATION:  

On replacement installations, mount the new thermostat in place of the old one 
unless the conditions listed below suggest otherwise. On new installations, 
follow the guidelines listed below.   
1. Locate the thermostat on an inside wall, at about 5 ft. (1.5m) above the floor, 
and in a room that is used often.   
2. Do not install it where there are unusual heating conditions, such as: direct 
sunlight, near a lamp, television, radiator, register, fireplace, on a wall opposite 
a stove, or that carries hot water pipes.   
3. Do not locate in unusual cooling conditions, such as: on a wall separating an 
unheated room, or in a draft from a stairwell, door, or window.     
4. Do not locate where air circulation is poor, such as: in a corner or alcove, or 
behind an open door.   
5. Do not locate in a damp area. This can lead to corrosion that may shorten 
thermostat life.   
6. Do not install the unit until all construction work and painting has been 
completed.  

 

REMOVING THE OLD THERMOSTAT:   

1. Switch OFF the electricity to both the furnace and air conditioner; then 
proceed with the following:   
2. Remove cover from old thermostat. Most are snap-on types and simply pull 
off, some have screws on the sides, and these must be loosened first. 
3. Take note the letters printed near the wire terminals. Attach labels (enclosed) 
to each wire for identification by terminal letter, not color.   
4. Make sure the wires do not fall back inside the wall, and remove and label 
one wire at a time. Do not allow wires to touch each other or any parts of the 
thermostat.  
5. Loosen all screws on the old thermostat and/or base, and remove it from the   
wall.  
 

C A U T I O N :

 

Be careful not to drop the body or disturb any 

of the electronic parts. 

 
MOUNTING THE NEW THERMOSTAT: 

 

1. Strip insulation leaving 3/8 in. (9.5mm) of bare wire on the ends and clean off 
any corrosion present.   
2. Fill the wall opening with non-combustible insulation to prevent drafts from 
affecting the thermostat while in use.   
3. Pull your new thermostat apart by applying pressure to the thumb tab on the 
bottom edge of the unit. While pressure is being applied to this release latch, 
pull the two halves of the thermostat apart near the bottom edge.   
4. Hold the base against the wall. Route the wires through the larger hole 
adjacent to the terminal block. Position the base for best appearance (to hide 
any marks from an old thermostat). Attach the base to the wall with the four 
screws provided.   
 

NOTE:

 If you are mounting the base to a soft material like plasterboard, or if 

you are using the old mounting holes, the screws may not hold. Drill a 3/16-in 
(4.8mm) hole at each screw location, and insert the plastic anchors provided. 
Then mount the base as described below.   

 
CONNECTING THE WIRES: 

 

5. Clean bare wire ends must be inserted terminal block 

and the brass terminal as shown here.   

6. Securely tighten all electrical terminal screws   

(even unused ones).

   

 

 

 WIRING INFORMATION  

 
** Complete heating or cooling system wiring can be found in the WIRE 
IDENTIFICATION AND WIRING SCHEMATICS section of this instruction 
sheet. The schematics shown provide component information for brand 
new installations or for un-referenced wires.   
 

 

 SETUP OPTIONS  

A table similar to this one shown below is printed on the thermostat's circuit 
board. There may be minor differences present in some of the wording of your 
specific model, but the function of each option will be the same.   

 

 

 

 

 

 
 
JUMPER SETTINGS:   

There are ten (10) headers (or jumpers) located inside the thermostat at the 
rear of the circuit board. These settings can be changed from their default 
values by removing its corresponding black jumper cap and reinstalling the cap 
so that it is positioned on the adjacent pair of metal pins. A change to ANY of 
the jumper settings will not be recognized until power to the thermostat is 
removed, and then power is restored again. This can simply be accomplished 
by removing the thermostat from the wired back plate. Each of these jumpers 
changes a different setup option. The choices for these options are listed in a 
table printed on the circuit board, and are also printed adjacent to each 
individual setting jumper.   
 

JP1 - HP-AUX ONLY:   

If you have a heat pump with auxiliary heat, and the heat pump is not working, 
you can use the auxiliary heat only by moving jumper 1 (heat pump) to jumper 
position 1(Aux only). 
 

JP2 - RC-RH CONNECTED OR SEPERATED: 

This setting controls whether the HVAC Power is single or RH-RC is separated. 
 

JP3&JP4 - [A] OR [Y1] TERMINAL USAGE OPTION: 

This setting determines how the thermostat will use the shared Y1/A terminal 
connection on the back plate. Choose the Jumper 3 (A) position to have the 
Y1/A terminal powered while in heat mode, and un-powered while in cool and 
off modes. Choose the Jumper 4 (Y1) position to have the Y1/A terminal 
powered while in cool mode, and un-powered while in heat and off modes.

   

 

JP5 - HEAT PUMP OR NORMAL:   

This setting determines whether the system is heat-pump or normal. 
 

JP6&JP7 - GAS / ELECTRIC FAN OPERATION:   

This setting changes whether the system's blower fan (if applicable) is 
controlled by the thermostat in HEAT mode. Choose JP7(ELECT) if you have 
electric heating, and require the thermostat to control the fan. Choose JP6(GAS) 
if you have a gas heating system, this will allow the furnace itself to control the 
operation of the blower fan. In the HEAT PUMP system, you also should choose 
JP7(ELECT). 
 

NOTE:

 If you have an Electric Heat system and the blower does not operate 

after installation, locate the "Gas/Electric" option jumper and ensure that it is in 
the "Electric" position. 

 

 
JP8&JP9 - [B] OR [O] TERMINAL USAGE OPTION:   

This setting determines how the thermostat will use the shared B/O terminal 
connection on the back plate. Choose the Jumper 8 (B) position to have the B/O 
terminal powered while in heat mode, and un-powered while in cool and off 
modes. Choose the Jumper 9 (O) position to have the B/O terminal powered 
while in cool mode, and un-powered while in heat and off modes.   
 

JP10 - FAHRENHEIT OR CELSIUS DISPLAY FORMAT:   

This setting controls whether the temperature is shown in degrees 
FAHRENHEIT or CELSIUS on the LCD display screen.   
 

 

 

COMPLETING THE INSTALLATION   

Install your new thermostat onto its base. To do this, start with the bottom tilted 

out towards you at first, and line up the two holes in the top of the thermostat 
with the two hooks on the top of the back plate. Slowly pivot the bottom of the 
thermostat towards the back plate and push firmly on the bottom half of the 
thermostat until it is securely latched to the back plate. If the two thermostat 
halves do not latch easily, remove and try again. Do not attempt to force them 
together.  
 

NOTE:

 Before use, remove the plastic film (if present) that is 

 

protecting the LCD display screen.   

 
Turn the electrical power back ON to both your heating and/or air conditioning 
systems. Verify that both systems (and the blower fan if used) are operating 
properly. When set to a high temperature, the heating system should provide 
warm air after a short time in Heat Mode. Likewise, a cooling system should 
provide cool air after a short time when set to a low temperature in Cool Mode. 
Usually, sound from the furnace and/or air conditioning units can be heard while 
either is running. If your system uses a blower fan, the rush of moving air should 
be heard within a short time after either has been    started. Your installation is 
now complete.

 

 

 

 

  FRONT PANEL ITEMS   

 
SYSTEM MODE SWITCH: 

 

The MODE switch has three positions: HEAT, OFF, and COOL. In the winter, 
set

 

the mode switch to HEAT to control your heating system; in the summer, set 

the switch to COOL to control your air conditioning. 

 

In the spring and fall, or when the windows are open, you can set the switch 
OFF. 
 

NOTE:

 When the system mode switch is in the OFF position, it is normal for the 

system's blower fan ("G" terminal if used) to still become activated depending 
upon the position of the FAN mode switch (see below). 

 

 
FAN MODE SWITCH: 

 

The FAN switch has two positions: ON and AUTO. 

 

• In the ON position, the system's blower fan will be commanded ON, and 
remain ON while the FAN switch is in the ON position (this also includes when 
the System Mode Switch is in the OFF position).   
• When the FAN switch is In the AUTO position, the operation of the blower fan 
is determined only by the on/off cycling of the heating and cooling systems.   
 

   

NOTE:

 The FAN switch only works if your system provides a wire 

 

for the thermostat's "G" terminal. 

 

 
PUSH BUTTONS: 

 

There are three push buttons in the middle of the unit's display screen. “UP” and 
“DOWN” buttons are used to adjust the set point temperature. “F” button is used 
to monitor the filter. 

 
FILTER MONITOR 

Your thermostat also keeps a record of the number of hours your filter has been 
in use. To maximize your system’s performance and energy efficiency, change 
or clear your filter regularly. 
When the total system run time for heat and cool reaches 400 hours, you need 
clean or change your system’s filter, “FILT” will continue to flash until the 
counter is set back to zero. 
Under the Filter count screen. Press and hold F for 3 seconds to reset the 
FILTER counter. The display will blink, and counters will be cleared to zero. 
 

 

 OPERATING INSTRUCTIONS  

 
TEMPERATURE ADJUSTMENT: 

 

While in HEAT or COOL mode, a single press on either the UP or DOWN button 
causes the word "TEMP SET" to appear on the screen. Once "TEMP SET" is 
present, the set point temperature can be altered by pressing either the UP or 
DOWN button once per degree

FAHRENHEIT

 of change.  

If there is a large thermal demand present which is greater than the first stage of 
heating (W1) or cooling (Y1) can accommodate for, then a second stage of 
heating (W2) or cooling (Y2) will be activated. 
When the second stage of either heating or cooling becomes active,

the word 

"AUX" will be shown on the display screen.   

 
TEMPERATURE LIMIT STOPS: 

There are two independent set temperature stops: a Maximum Heat Set 

• Large, Easy To Read Display 

with LED Backlight   

• F / C Selectable Temperature   

Display  

• Fixed 4 Minute Minimum Delay 

For Compressor Protection 

Celcious
DISPLAY

Fahrenheit
  DISPLAY

NO O

NO B

O

JP9

B

JP8

NO FAN

JP7

ELECT
 HEAT

GAS
HEAT

JP6

NORMAL

HEAT
PUMP

JP5

NO Y1

Y1

JP4

NO A

A

JP3

    RC-RH
SEPERATE

   RC-RH
CONCTED

JP2

NORMAL

HP-AUX
  ONLY

JP1

OFF

ON

Jumper

Factory
Default

NO FAN

OFF

ON

OFF

ON

OFF

OFF

ON

ON

OFF

JP10

ON

OFF