5
ELECTRICAL REQUIREMENTS
Electric Dryer:
(RDE350AW)
Circuit
Individual 30 Amp branch circuit fused with 30 Amp time-delay fuses or circuit
breakers. Use seperately fused circuits for washers and dryers, and DO NOT
operate a washer and dryer on the same circuit.
Power Supply
3 or 4 wire, 120/240 Volt, 1 Phase, 60Hz, AC
(Canada - 120/240 Volt, 1 Phase, 60 Hz, AC)
Power Supply Cord Kit
(Not supplied when sold in US. Must be purchased to meet local electrical
codes.) The dryer MUST employ a 3-conductor power supply cord NEMA
10-30 Type SRDT rated at 240 Volt AC minimum, 30 Amp, with 3 open end
INSTALLATION INSTRUCTIONS
English
Risk of Fire:
SAVE THESE INSTRUCTIONS
Tools and materials required
• Phillips-Head and flathead screwdrivers
• Channel-lock adjustable pilers
• 1/2-inch open-end wrench
• Carpenter’s level
• Measuring tape (12ft. min.)
• Duct tape
• Pipe thread sealer (Gas)
• Rigid or flexible metal 4 inch
(102cm) duct
• Vent hood
Safety Warning:
1.
Before starting installation, make sure that the gas shut off valve is in the
off position.
2. All old gas connectors and gas piping should be discarded.
WARNING
1.Clothes dryer installation must be performed by a qualified installer.
2.Install the clothes dryer according to the manufacturer’s instructions and local
codes.
3.Do not install a clothes dryer with flexible plastic venting materials.
If flexible metal (foil type) duct is installed,it must be of a specific type identified by
the appliance manufacturer as suitable for use with clothes dryers. Flexible venting
materials are known to collapse, be easily crushed,and trap lint.These conditions
will obstruct clothes dryer airflow and increase the risk of fire.
4.To reduce the risk of severe injury or death, follow all installation instructions.