4. Thread a U.L. approved 30 Amp power cord. NEMA 14-30 type ST or SRDT
through the strain relief.
5. Attach the green power cord ground wire to the cabinet with green ground
screw.
6.
7. Attach the red and black power cord conductors to the outer brass-colored
terminals on the terminal block.
Warning:
Do not make a sharp bend or crimp the wiring /conductor at
connections.
8. Tighten the screws securing the cord restraint firmly against the power cord.
9. Tighten the strain relief nut securely so that the strain relief does not turn.
10. Reinstall the terminal block cover.
NOTE: DO NOT connect the dryer to L.P. gas service without
converting the gas valve. An L.P. Conversion Kit must be
installed by a qualified gas technician.
1. Remove the shipping cap from gas pipe at the rear of the dryer.
2. Connect a 1/2 inch (1.27cm) I.D. semi-rigid or approved pipe from gas supply line to
the 3/8 inch (0.96cm) pipe located on the back of the dryer. Use a 1/2 inch to 3/8
inch (1.27cm to 0.96cm) reducer for a connection. Apply an approved thread sealer
that is resistant to the corrosive action of liquified gases on all pipe connections.
3. Open the shutoff valve in the gas supply line.
4. Test all connections by brushing on a soapy water solution.
NEVER TEST FOR GAS
LEAKS WITH AN OPEN FLAME.
5. Connect the exhaust duct to the outside exhaust system. Use duct tape to seal all joints.
6. With the dryer in its final position, adjust one or more of the legs until the dryer is resting
solid on all four legs. Place a level on top of the dryer.
THE DRYER MUST BE LEVEL
AND RESTING SOLID ON ALL FOUR LEGS.
7. Plug the power cord into a grounded outlet.
NOTE:
check to ensure power is
OFF
at
circuit breaker/fuse box before plugging the power cord into the outlet.
8. Turn on the power at the circuit breaker/fuse box.
Before operating the dryer, make sure the dryer area is clean and free
from combustible materials, gasoline, and other flammable vapors. Also
see that nothing (such as boxes, clothing, etc.) obstructs the flow of
combustion and ventilation air through the louvered panel located on the
rear of the dryer.
9. Run the dryer through a cycle check for proper operation.
NOTE:
On gas dryers, before the burner will light, it is necessary for the gas line to
be bled of air. If the burner does not light within 45 seconds the first
time
the dryer is turned on, the safety switch will shut the burner off. If this
happens, turn the dryer to “OFF” and wait 5 minutes before making
another attempt to light.
NOTE:
Follow instructons supplied with kit.
GAS CONNECTIONS
GAS
Dryer
(RDG350A)
Attach the white (neutral) power cord conductors and the green ground wire
from the dryer harness to the brass-colored center terminal on the terminal
block. Tighten the screw securely.