Haier HSU-09HVD03/R2 - annexe 2 Installation Manual Download Page 1

No.

Accessory parts

Remote controller

R-03 dry battery

Mounting plate

Drain hose

Screw

Plastic cap

1

1

2

3

4

5

6

7

8

9

10

2

1

1

4

Drain-elbow

Cushion

1

4

Number

    of

articles

Accessory parts

4X25

 Change for

 fresh air box

 Change for

fresh air  tube(suit)

Outlet joint

1

1

2

No.00105

1

Installation Manual of Room Air Conditioner

The models adopt HFC free refrigerant R410A

A

B

C

D

E

F

G

Optional parts for piping

Mark

Parts name

more than 5cm

more than 10cm

more than 60cm

more than 15cm

Non-adhesive tape

The marks from     to     in the figure are the parts numbers.

The distance between the indoor unit and the floor should be
more than 2m.

more than 10cm

more than 10cm

more than 10cm

Adhesive tape

Saddle(L.S) with screws

Attention must be paid to
the rising up of drain hose

Arrangement of piping directions

Rear left

Rear

right

Left

Below

Right

Connecting electric cable
for indoor and outdoor

Drain hose

Heating insulating material

Piping hole cover

Read this manual before installation

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)

5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife

9.Nipper

12.Reamer

10.Gas leakage detector or
     soap-and-water solution
11.Measuring tape

Explain sufficiently the operating means to the user
according to this manual.

A

G

G

F

A

C

Drawing for the installation of indoor and outdoor units

Necessary Tools for Installation

9

10

D

E

Summary of Contents for HSU-09HVD03/R2 - annexe 2

Page 1: ...nd the floor should be more than 2m more than 10cm more than 10cm more than 10cm Adhesive tape Saddle L S with screws Attention must be paid to the rising up of drain hose Arrangement of piping directions Rear left Rear right Left Below Right Connecting electric cable for indoor and outdoor Drain hose Heating insulating material Piping hole cover Read this manual before installation 1 Driver 2 Hac...

Page 2: ...n be left In the case of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened Place which is less affected by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to the nei...

Page 3: ...us article When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a hole of 70 mm in diameter slightly descending to outside the wall Install piping hole cover and seal it off with putty after installation Section of wall hole Piping hole pipe Outdoor side Thick...

Page 4: ... outside the room cable into left side of the wall hole in which the pipe has already existed 2 Pull out the cable on the front side and connect the cable making a loop signal wire Change for fresh air tube 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then ...

Page 5: ...n please change it with the type of T 3 15A 250V 3 The wiring method should be in line with the local wiring standard 4 After installation the power plug should be easily reached 5 6 Easily demount cleaning of indoor unit 1 Top inlet can be taken down Open the inlet grille press the claw of the clip on the unit then take down the top inlet according to figure 1 claw of the clip Figure 1 Figure 2 F...

Page 6: ...ease attach it as figure Note Only for heat pump unit Forced fastening without careful centering may damage the threads and cause a leakage of gas Pipe Diameter Liquid side 6 35mm 1 4 Gas side 9 52mm 3 8 Fastening torque Drawing for the installation of indoor and outdoor units 1 Remove the four screws of change for fresh air box from the back cover 2 Use six screws to fix the change new wind box o...

Page 7: ...as leakage No gas leakage In case of gas leakage tighten parts of pipe connection If leakage stops then proceed steps Detach the charge hose from the service port open 2 way valve and 3 way Turn the valve rod anticlockwise until hitting lightly To prevent the gas leakage turn the service port s cap the valve rod s cap for 2 way valve and 3 way s a little more than the point where the torque increa...

Page 8: ...rried out Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly explain to our customers how to operate through the...

Page 9: ...ier Road Qingdao P R China IT CE All the products are in conformity with the following European provision Electromagnetic CompatibilitY 89 336 EEC ROHS The products are fulfilled with the requirements in the directive 2002 95 EEC of the European parliament and of the council on the Restriction of the use of Certain Hazardous Sub stances in Electrical and Electronic Equipment EU RoHS Directive WEEE...

Page 10: ...DIRECTIVES EUROPÉENNES POUR LES MODÈLES Haier Industrial Park No 1 Haier Road Qingdao P R China FR CE Alle Produkte erfüllen die folgenden europäischen Richtlinien EMV Richtlinie 89 336 EWG ROHS Das Produkt erfüllt die Richtlinie 2002 95 EWG zur Beschrän kung der Verwendung bestimmter gefährlicher Stoffe in Elektro und Elektronikgeräten WEEE Verbraucherinformation laut europäischer Richtlinie 2002...

Reviews: