No.0010504855

Installation Manual of Room Air Conditioner

The marks from     to     in the figure are the parts numbers.

The distance between the indoor unit and the floor should be
more than 2m.

Read this manual before installation

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)

5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife

9.Nipper

12.Reamer

10.Gas leakage detector or
     soap-and-water solution
11.Measuring tape

Explain sufficiently the operating means to the user
according to this manual.

A

G

No.

Accessory parts

Remote controller

R-03 dry battery

Mounting plate

Drain hose

Steel nail, cement

Screw

Plastic cap

Drain-elbow

Cover

Cushion

1

1

2

3

4

5

6

7

8

9

2

1

1

6

4

1

1

4

Number
    of
articles

Accessory parts

4X50

4X25

more than 5cm

more than 10cm

more than 60cm

more than 15cm

more than 10cm

more than 10cm

more than 10cm

Attention must be paid to
the rising up of drain hose

G

F

A

Drawing for the installation of indoor and outdoor units

Necessary Tools for Installation

A

B

C

D

E

F

G

Optional parts for piping

Mark

Parts name

Non-adhesive tape

Adhesive tape

Saddle(L.S) with screws

Connecting electric cable
for indoor and outdoor

Drain hose

Heating insulating material

Piping hole cover

Arrangement of piping directions

Rear left

Rear

right

Left

Below

Right

C

D

E

Summary of Contents for HSU-09H03/R

Page 1: ...te controller R 03 dry battery Mounting plate Drain hose Steel nail cement Screw Plastic cap Drain elbow Cover Cushion 1 1 2 3 4 5 6 7 8 9 2 1 1 6 4 1 1 4 Number of articles Accessory parts 4X50 4X25 more than 5cm more than 10cm more than 60cm more than 15cm more than 10cm more than 10cm more than 10cm Attention must be paid to the rising up of drain hose G F A Drawing for the installation of indo...

Page 2: ...ase of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened Place which is less affected by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to the neighbors Place where...

Page 3: ...ounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a hole of 66 mm in diameter slightly descending to outside the wall Install piping hole cover and seal it off with putty after installation Section of wall hole Piping hole pipe Outdoor side Thickness of wall Indoor s...

Page 4: ...e pipe has already existed 2 Pull out the cable on the front side and connect the cable making a loop 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then connect them 3 Coat the flaring seal face with refrigerant oil and connect pipes Cover the connection par...

Page 5: ...gure 3 BRN WHT BLK RED YEL GRN BRN WHT BLK RED YEL GRN Indoor unit Outdoor unit HSU 09H03 R QXF HSU 12H03 R QXF HSU 09H03 R DB HSU 12H03 R DB HSU 09C03 R DB HSU 12C03 R DB YEL GRN YEL GRN Indoor unit Outdoor unit RED RED BLK BLK WHT WHT Two ways for the installation of indoor part as illustrated Way One When the pipes go from the back of the indoor unit you can connect the fresh air tube with the ...

Page 6: ...inal block and insert the plugs fully into terminal block then tighten the screws If wiring is not correct proper operation can not be carried out and controller may be damaged If the drain elbow is used please attach it as figure Note Only for heat pump unit Drawing for the installation of indoor and outdoor units Insert the cable according to terminal number in the same manner as the indoor unit...

Page 7: ...s using specified torque 5 Tighten the caps on the valves with specified torque Valve rod Valve cap 7 9 20 25 Tighten torque N m When connecting pipe exceeds 5 meters 16g refrigerant shall be added per exceeding meter Charge according to the following list Piping length Additional amount 5m 7m 10m No need 32g During this procedure 50g refrigerant will be discharged in piping This must be strictly ...

Page 8: ...n pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly explain to our customers how to operate through the instruction manual Gas leak from pipe connecting Heat insulation of pipe connecting Are the connecting wirings of indoor and outdoor firmly inserted to ...

Reviews: